Toward cardiovascular MRI at 7 T: clinical needs, technical solutions and research promises

被引:57
作者
Niendorf, Thoralf [1 ,2 ]
Sodickson, Daniel K. [3 ]
Krombach, Gabriele A. [4 ]
Schulz-Menger, Jeanette [1 ,2 ,5 ]
机构
[1] Max Delbrueck Ctr Mol Med, Berlin Ultrahigh Field Facil, D-13125 Berlin, Germany
[2] Humboldt Univ, ECRC, Berlin, Germany
[3] NYU, Sch Med, Dept Radiol, Ctr Biomed Imaging, New York, NY USA
[4] Univ Klinikum Giessen & Marburg, Dept Diagnost Radiol, Giessen, Germany
[5] HELIOS Klinikum Berlin Buch, Berlin, Germany
关键词
Cardiovascular MRI; Ultrahigh-field imaging; Multiple transmit; MRtechnology; Parallel imaging; MAGNETIC-RESONANCE; COMPUTED-TOMOGRAPHY; PARALLEL EXCITATION; RF TRANSMISSION; ABSORPTION RATE; CARDIAC MR; 3.0; TESLA; COIL; FEASIBILITY; ANGIOGRAPHY;
D O I
10.1007/s00330-010-1902-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To consider potential clinical needs, technical solutions and research promises of ultrahigh-field strength cardiovascular MR (CMR). A literature review is given, surveying advantages and disadvantages of CMR at ultrahigh fields (UHF). Key concepts, emerging technologies, practical considerations and applications of UHF CMR are provided. Examples of UHF CMR imaging strategies and their added value are demonstrated, including the numerous unsolved problems. A concluding section explores future directions in UHF CMR. UHF CMR can be regarded as one of the most challenging MRI applications. Image quality achievable at UHF is not always exclusively defined by signal-to-noise considerations. Some of the inherent advantages of UHF MRI are offset by practical challenges. But UHF CMR can boast advantages over its kindred lower field counterparts by trading the traits of high magnetic fields for increased temporal and/or spatial resolution. CMR at ultrahigh-field strengths is a powerful motivator, since speed and signal may be invested to overcome the fundamental constraints that continue to hamper traditional CMR. If practical challenges can be overcome, UHF CMR will help to open the door to new approaches for basic science and clinical research.
引用
收藏
页码:2806 / 2816
页数:11
相关论文
共 49 条
[1]   Diagnostic performance of cardiovascular magnetic resonance in patients with suspected acute myocarditis -: Comparison of different approaches [J].
Abdel-Aty, H ;
Boyé, P ;
Zagrosek, A ;
Wassmuth, R ;
Kumar, A ;
Messroghli, D ;
Bock, P ;
Dietz, R ;
Friedrich, MG ;
Schulz-Menger, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (11) :1815-1822
[2]   Comparison of left ventricular function assessment using phonocardiogram- and electrocardiogram-triggered 2D SSFP CINE MR imaging at 1.5 T and 3.0 T [J].
Becker, Meike ;
Frauenrath, Tobias ;
Hezel, Fabian ;
Krombach, Gabriele A. ;
Kremer, Ute ;
Koppers, Benedikt ;
Butenweg, Christoph ;
Goemmel, Andreas ;
Utting, Jane F. ;
Schulz-Menger, Jeanette ;
Niendorf, Thoralf .
EUROPEAN RADIOLOGY, 2010, 20 (06) :1344-1355
[3]  
BRANTS A, 2010, P INT SOC MAG RESON, V18, P1299
[4]   Gadolinium(III) chelates as MRI contrast agents: Structure, dynamics, and applications [J].
Caravan, P ;
Ellison, JJ ;
McMurry, TJ ;
Lauffer, RB .
CHEMICAL REVIEWS, 1999, 99 (09) :2293-2352
[5]   Medical Progress: Myocarditis. [J].
Cooper, Leslie T., Jr. .
NEW ENGLAND JOURNAL OF MEDICINE, 2009, 360 (15) :1526-1538
[6]  
DIERINGER MA, 2010, P INT SOC MAG RESON, V18, P3583
[7]  
Fischer SE, 1999, MAGN RESON MED, V42, P361, DOI 10.1002/(SICI)1522-2594(199908)42:2<361::AID-MRM18>3.0.CO
[8]  
2-9
[9]   Acoustic method for synchronization of magnetic resonance imaging (MRI) [J].
Frauenrath, Tobias ;
Niendorf, Thoralf ;
Kob, Malte .
ACTA ACUSTICA UNITED WITH ACUSTICA, 2008, 94 (01) :148-155
[10]   Feasibility of Cardiac Gating Free of Interference With Electro-Magnetic Fields at 1.5 Tesla, 3.0 Tesla and 7.0 Tesla Using an MR-Stethoscope [J].
Frauenrath, Tobias ;
Hezel, Fabian ;
Heinrichs, Uwe ;
Kozerke, Sebastian ;
Utting, Jane F. ;
Kob, Malte ;
Butenweg, Christoph ;
Boesiger, Peter ;
Niendorf, Thoralf .
INVESTIGATIVE RADIOLOGY, 2009, 44 (09) :539-547