Outcomes after revision of metal on metal hip resurfacing to total arthroplasty using the direct anterior approach

被引:15
作者
Bouveau, Victoire [1 ]
Haen, Thomas-Xavier [1 ]
Poupon, Joel [2 ]
Nich, Christophe [1 ]
机构
[1] Versailles St Quentin En Yvelines Univ, Raymond Poincare Hosp, AP HP, Dept Traumatol & Orthopaed Surg, 104 Blvd Raymond Poincare, Versailles, France
[2] Paris 7 Diderot Univ, Dept Biol Toxicol, Lariboisiere Hosp, AP HP, 2 Rue Ambroise Pare, F-75475 Paris 10, France
关键词
Hip resurfacing; Metal-on-metal; Revision; Total hip arthroplasty; Serum ion level; ON-METAL; REPLACEMENT; BEARINGS; YOUNG; TOOL;
D O I
10.1007/s00264-018-3858-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundFunction after revision total hip arthroplasty (THA) in failed metal-on-metal (MoM) hip resurfacing arthroplasty (HRA) is variable, but post-operative complication rates are reportedly high. We hypothesized HRA conversion to THA using the direct anterior approach (DAA) would be associated with optimal outcome.MethodsSeventeen MoM-HRAs in 15 patients (seven males, eight females) were revised through the DAA. The mean age was 45years (28-59yrs). The most common indications for revision were aseptic loosening of the acetabular component or of the femoral component and femoral neck fracture. In 16 hips, a conversion to a ceramic-on-ceramic (CoC) (13 hips) or to a metal-on polyethylene (MOP) (2), or to a large-head MoM (1) THA was done. An isolated femoral revision was done in one hip.ResultsAfter 6.73years, no hip had required a re-revision. The Postel-Merle d'Aubigne (PMA) functional score improved from 9 (4-14) to 16 (12-18) (p<0.001). An intra-operative fracture of the greater trochanter (one hip) and dysesthesia of the lateral femoral cutaneous nerve (four hips) were reported. Mean serum chromium concentration decreased from 33.2g/L (11.8-62g/L) pre-operatively to 5.8g/L (0.4-35.5g/L) post-operatively (p<0.001), and mean serum cobalt concentration decreased from 35.8g/L (6.3-85.5g/L) to 4.7g/L (0.26-25.7g/L) (p=0.003).Conclusion Revision of failed MoM-HRA using the DAA resulted in an acceptable clinical outcome, no specific complication and no further surgery. A consistent decline in serum ion levels may be expected following HRA conversion to THA.
引用
收藏
页码:2543 / 2548
页数:6
相关论文
共 27 条
[1]   Early results of conversion of a failed femoral component in hip resurfacing arthroplasty [J].
Ball, Scott T. ;
Le Duff, Michel J. ;
Amstutz, Harlan C. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (04) :735-741
[2]   What Happens to Serum Metal Ion Levels After a Metal-on-Metal Bearing is Removed? [J].
Ball, Scott T. ;
Severns, Dustyn ;
Linn, Michael ;
Meyer, R. Scott ;
Swenson, F. Craig .
JOURNAL OF ARTHROPLASTY, 2013, 28 (08) :53-55
[3]   ECTOPIC OSSIFICATION FOLLOWING TOTAL HIP-REPLACEMENT - INCIDENCE AND A METHOD OF CLASSIFICATION [J].
BROOKER, AF ;
BOWERMAN, JW ;
ROBINSON, RA ;
RILEY, LH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (08) :1629-1632
[4]   Metal Ion Measurement as a Diagnostic Tool to Identify Problems with Metal-on-Metal Hip Resurfacing [J].
de Smet, K. ;
de Haan, R. ;
Calistri, A. ;
Campbell, P. A. ;
Ebramzadeh, E. ;
Pattyn, C. ;
Gill, H. S. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A :202-208
[5]  
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[6]   Do Revised Hip Resurfacing Arthroplasties Lead to Outcomes Comparable to Those of Primary and Revised Total Hip Arthroplasties? [J].
Desloges, William ;
Catelas, Isabelle ;
Nishiwaki, Toru ;
Kim, Paul R. ;
Beaule, Paul E. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (11) :3134-3141
[7]   POROUS-COATED HIP-REPLACEMENT - THE FACTORS GOVERNING BONE INGROWTH, STRESS SHIELDING, AND CLINICAL-RESULTS [J].
ENGH, CA ;
BOBYN, JD ;
GLASSMAN, AH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (01) :45-55
[8]   Distributed Analysis of Hip Implants Using Six National and Regional Registries: Comparing Metal-on-Metal with Metal-on-Highly Cross-Linked Polyethylene Bearings in Cementless Total Hip Arthroplasty in Young Patients [J].
Furnes, Ove ;
Paxton, Elizabeth ;
Cafri, Guy ;
Graves, Stephen ;
Bordini, Barbara ;
Comfort, Thomas ;
Coll Rivas, Moises ;
Banerjee, Samprit ;
Sedrakyan, Art .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A :25-33
[9]   Hip resurfacings revised for inflammatory pseudotumour have a poor outcome [J].
Grammatopoulos, G. ;
Pandit, H. ;
Kwon, Y. -M. ;
Gundle, R. ;
McLardy-Smith, P. ;
Beard, D. J. ;
Murray, D. W. ;
Gill, H. S. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (08) :1019-1024
[10]   Outcomes After Revision of Metal-on-Metal Hip Resurfacing Arthroplasty [J].
Gross, Thomas P. ;
Liu, Fei .
JOURNAL OF ARTHROPLASTY, 2014, 29 (09) :219-223