Radiological assessment of a new bone densitometer - The Lunar EXPERT

被引:24
|
作者
Njeh, CF
Apple, K
Temperton, DH
Boivin, CM
机构
[1] Medical Physics Department, Univ. Hospital Birmingham NHS Trust, Edgbaston
[2] Bone Densitometry Service, Medical Physics Department, University Hospital, Edgbaston
来源
BRITISH JOURNAL OF RADIOLOGY | 1996年 / 69卷 / 820期
关键词
D O I
10.1259/0007-1285-69-820-335
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Dual energy X-ray absorptiometry (DXA) is one of the most widely used techniques in the management of osteoporosis and other skeletal diseases. Although patient doses from DXA are generally low, it is still necessary to measure them to assess the risk of radiation injury. We report on a study to estimate the effective dose (ED) to patients and staff from a new DXA scanner-the Lunar EXPERT, and make a comparison with a similar study carried out on a Lunar DPX-L. The entrance surface doses were measured to be 895 mu Gy and 10.25 mu Gy for the EXPERT and DPX-L, respectively. The EXPERT maximum EDs were calculated to be 74.7 mu Sv and 44.9 mu Sv for the anteroposterior (AP) lumbar spine and the proximal femur, respectively. More than 50% reduction in ED could be achieved by using a smaller scanning width. The maximum EDs for the DPX-L were calculated to be 0.21 mu Sv and 0.15 mu Sv for the AP lumbar spine and the proximal femur, respectively. The scattered dose rates (ambient dose equivalent) were measured to be less than 2 and less than 1 mu Sv h(-1) at 50 cm and 100 cm, respectively, for the DPX-L, and the equivalent values for the EXPERT were 240 and 64 mu Sv h(-1). Although both the patient dose and scattered dose rates are quite low relative to other radiological examinations, good practice aimed at dose reduction should still be implemented. Whilst protection for the operator is not needed for the DPX-L system, it may be (depending on the size of the room) for the EXPERT system.
引用
收藏
页码:335 / 340
页数:6
相关论文
共 50 条
  • [41] ASSESSMENT OF VERTEBRAL DEFORMATION WITH A HIGH-RESOLUTION FAN-BEAM BONE DENSITOMETER
    LANG, T
    FAN, B
    WU, C
    LI, J
    TAKADA, M
    GLUER, CC
    GENANT, H
    JOURNAL OF BONE AND MINERAL RESEARCH, 1995, 10 : S367 - S367
  • [42] MODIFICATION OF A BALDWIN RADIOLOGICAL DENSITOMETER TO MEASURE DENSITIES UP TO 7.5
    HILL, MJ
    POWNALL, DR
    BRITISH JOURNAL OF RADIOLOGY, 1966, 39 (464): : 633 - &
  • [43] New concepts in the radiological assessment of COPD
    Coxson, HO
    Rogers, RM
    SEMINARS IN RESPIRATORY AND CRITICAL CARE MEDICINE, 2005, 26 (02) : 211 - 220
  • [44] DETERMINATION OF LUNAR LIMB USING MICRO-DENSITOMETER OF NICE OBSERVATORY
    MEYER, F
    MOON AND THE PLANETS, 1979, 20 (02): : 169 - 172
  • [45] NEW VARIANT OF RADIOLOGICAL SUBSTANCE ANALYSIS OF BONE
    ROSENKRANZ, G
    TELLKAMP, H
    RADIOLOGIA DIAGNOSTICA, 1977, 18 (05) : 693 - 699
  • [46] Evaluation of precision and accuracy of the lunar iDXA fan-beam densitometer
    Faulkner, K. G.
    Wacker, W. K.
    Franz, J. R.
    Riewe, K. P.
    Barden, H. S.
    OSTEOPOROSIS INTERNATIONAL, 2006, 17 : S293 - S294
  • [47] TOTAL-BODY DENSITY USING THE EXPERT IMAGING DENSITOMETER
    ERGUN, D
    YAMUR, C
    HAARSMA, M
    BISEK, J
    NORD, R
    HANSON, J
    JOURNAL OF BONE AND MINERAL RESEARCH, 1995, 10 : S370 - S370
  • [48] Whole body and lateral vertebral assessment with a digital 2D bone densitometer.
    Robert-Coutant, C
    Julier, M
    Gerfault, L
    Gonon, G
    Gaucher, L
    Gagnepain, C
    Grando, R
    Dinten, JM
    JOURNAL OF BONE AND MINERAL RESEARCH, 2003, 18 : S205 - S205
  • [49] EVALUATION OF A NEW SCANNING DENSITOMETER
    CAPUTO, MJ
    DOUMAS, B
    HOSTY, TA
    HOLLENBECK, M
    CLINICAL CHEMISTRY, 1971, 17 (07) : 644 - +
  • [50] RELIABILITY AND VALIDITY OF THE BINDEX® ULTRASOUND BONE DENSITOMETER
    Behrens, M.
    Karjalainen, J.
    Felser, S.
    Mau-Moeller, A.
    Weippert, M.
    Pollex, J.
    Skripitz, R.
    Herlyn, P.
    Fischer, D. -C.
    Bruhn, S.
    Schober, H. -C.
    Zschorlich, V.
    Mittlmeier, T.
    OSTEOPOROSIS INTERNATIONAL, 2016, 27 : S468 - S469