Radiological assessment of a new bone densitometer - The Lunar EXPERT

被引:24
|
作者
Njeh, CF
Apple, K
Temperton, DH
Boivin, CM
机构
[1] Medical Physics Department, Univ. Hospital Birmingham NHS Trust, Edgbaston
[2] Bone Densitometry Service, Medical Physics Department, University Hospital, Edgbaston
来源
BRITISH JOURNAL OF RADIOLOGY | 1996年 / 69卷 / 820期
关键词
D O I
10.1259/0007-1285-69-820-335
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Dual energy X-ray absorptiometry (DXA) is one of the most widely used techniques in the management of osteoporosis and other skeletal diseases. Although patient doses from DXA are generally low, it is still necessary to measure them to assess the risk of radiation injury. We report on a study to estimate the effective dose (ED) to patients and staff from a new DXA scanner-the Lunar EXPERT, and make a comparison with a similar study carried out on a Lunar DPX-L. The entrance surface doses were measured to be 895 mu Gy and 10.25 mu Gy for the EXPERT and DPX-L, respectively. The EXPERT maximum EDs were calculated to be 74.7 mu Sv and 44.9 mu Sv for the anteroposterior (AP) lumbar spine and the proximal femur, respectively. More than 50% reduction in ED could be achieved by using a smaller scanning width. The maximum EDs for the DPX-L were calculated to be 0.21 mu Sv and 0.15 mu Sv for the AP lumbar spine and the proximal femur, respectively. The scattered dose rates (ambient dose equivalent) were measured to be less than 2 and less than 1 mu Sv h(-1) at 50 cm and 100 cm, respectively, for the DPX-L, and the equivalent values for the EXPERT were 240 and 64 mu Sv h(-1). Although both the patient dose and scattered dose rates are quite low relative to other radiological examinations, good practice aimed at dose reduction should still be implemented. Whilst protection for the operator is not needed for the DPX-L system, it may be (depending on the size of the room) for the EXPERT system.
引用
收藏
页码:335 / 340
页数:6
相关论文
共 50 条
  • [1] ASSESSMENT OF A NEW DUAL PHOTON BONE DENSITOMETER
    EUSTACE, MW
    CULLUM, ID
    SPELLER, RD
    ELL, PJ
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1988, 14 (5-6): : 312 - 312
  • [2] Improved vertebral morphometry precision using images from lunar EXPERT-XL bone densitometer
    Harvey, SB
    Hukins, DWL
    Hutchison, KM
    Rennie, EC
    Reid, DM
    JOURNAL OF BONE AND MINERAL RESEARCH, 1997, 12 : T657 - T657
  • [3] An assessment of the radiation dose to patients and staff from a Lunar Expert-XL fan beam densitometer
    Steel, SA
    Baker, AJ
    Saunderson, JR
    PHYSIOLOGICAL MEASUREMENT, 1998, 19 (01) : 17 - 26
  • [4] Factors affecting accuracy of bone mineral density measurement using a Lunar Expert-XL fan beam densitometer
    Goodby, A
    Steel, SA
    OSTEOPOROSIS INTERNATIONAL, 2000, 11 : 29 - 29
  • [5] NEW IMAGING BONE DENSITOMETER
    GAUNTT, D
    BISEK, J
    MAZESS, RB
    JOURNAL OF BONE AND MINERAL RESEARCH, 1993, 8 : S354 - S354
  • [6] The effect of tissue depth and scan mode on bone mineral density using a Lunar Expert-XL fan beam densitometer
    Goodby, A
    Steel, SA
    OSTEOPOROSIS INTERNATIONAL, 2000, 11 : S44 - S44
  • [7] Serial hand done densitometry with lunar-xl expert densitometer in the assessment of patients with very early inflammatory arthritis.
    Green, MJ
    Proudman, S
    Stewart, S
    Wakefield, RJ
    McGonagle, D
    Smith, MA
    Emery, P
    ARTHRITIS AND RHEUMATISM, 1997, 40 (09): : 1565 - 1565
  • [8] Precision and accuracy of the GE lunar DPX-Bravo bone densitometer.
    Nord, RH
    Barden, HS
    Krepanith, S
    Faulkner, KG
    JOURNAL OF BONE AND MINERAL RESEARCH, 2003, 18 : S204 - S205
  • [9] Converting data from the lunar DPX-IQ bone densitometer for interoperability
    Tan, L. K.
    Ng, K. H.
    Shaharuddin, S.
    Abdullah, B. J. J.
    3RD KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2006, 2007, 15 : 259 - +
  • [10] Comparison of the precision of two vertebral morphometry programs for the Lunar EXPERT-XL imaging densitometer
    Harvey, SB
    Hutchison, KM
    Rennie, EC
    Hukins, DWL
    Reid, DM
    BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (844): : 388 - 398