Simultaneous detection of ethanol, glucose and glycerol in wines using pyrroloquinoline quinone-dependent dehydrogenases based biosensors

被引:65
作者
Niculescu, M
Mieliauskiene, R
Laurinavicius, V
Csöregi, E
机构
[1] Lund Univ, Dept Biotechnol, S-22100 Lund, Sweden
[2] Lithuania Acad Sci, Inst Biochem, LT-2021 Vilnius, Lithuania
关键词
ethanol; glucose; glycerol; biosensor; wine analysis;
D O I
10.1016/S0308-8146(03)00118-3
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Arnperornetric biosensors based on corresponding dehydrogenases have been developed for the determination of ethanol, glucose and glycerol. The enzymes have been integrated in redox hydrogels using an Os complex-modified non-conducting polymer employed as the electrochemical mediator and poly(ethyleneglycol)-diglycidyl ether (PEGDGE) as the cross-linking agent. The developed biosensors showed a sensitive response to ethanol, glucose and glycerol within the concentration range 2.5-250, 20-800, and 1-200 muM. detection limits of 1.2, 9 and 1 muM, and sensitivities of 220, 87 and 32 mA M-1 cm(-2), respectively. The ethanol, glucose and glycerol content of several types of wine was determined with these biosensors, and the results were compared with those obtained by spectrophotometric methods. The developed biosensors have been successfully employed for simultaneous determination of all these substrates at the required sensitivity. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:481 / 489
页数:9
相关论文
共 29 条
  • [21] BIENZYME SENSORS BASED ON ELECTRICALLY WIRED PEROXIDASE
    OHARA, TJ
    VREEKE, MS
    BATTAGLINI, F
    HELLER, A
    [J]. ELECTROANALYSIS, 1993, 5 (9-10) : 825 - 831
  • [22] Razumiene J, 2002, ELECTROANAL, V14, P43, DOI 10.1002/1521-4109(200201)14:1<43::AID-ELAN43>3.0.CO
  • [23] 2-5
  • [24] Sequential injection flow system with improved sample throughput: determination of glycerol and ethanol in wines
    Segundo, MA
    Rangel, AOSS
    [J]. ANALYTICA CHIMICA ACTA, 2002, 458 (01) : 131 - 138
  • [25] INTERNAL SUPPLY OF COENZYME TO AN AMPEROMETRIC GLUCOSE BIOSENSOR BASED ON A CHEMICALLY MODIFIED ELECTRODE
    SKOOG, M
    JOHANSSON, G
    [J]. BIOSENSORS & BIOELECTRONICS, 1991, 6 (05) : 407 - 412
  • [26] Bienzymatic amperometric biosensor for glucose based on polypyrrole/ceramic carbon as electrode material
    Tian, FM
    Zhu, GY
    [J]. ANALYTICA CHIMICA ACTA, 2002, 451 (02) : 251 - 258
  • [27] Integrated ethanol biosensors based on carbon paste electrodes modified with [Re(phen-dione)(CO)3Cl] and [Fe(phen-dione)3](PF6)2
    Tobalina, F
    Pariente, F
    Hernández, L
    Abruña, HD
    Lorenzo, E
    [J]. ANALYTICA CHIMICA ACTA, 1999, 395 (1-2) : 17 - 26
  • [28] Alcohol biosensors based on coupled oxidase-peroxidase systems
    Vijayakumar, AR
    Csoregi, E
    Heller, A
    Gorton, L
    [J]. ANALYTICA CHIMICA ACTA, 1996, 327 (03) : 223 - 234
  • [29] Direct liquid chromatographic analysis of resveratrol derivatives and flavanonols in wines with absorbance and fluorescence detection
    Vitrac, X
    Monti, JP
    Vercauteren, J
    Deffieux, G
    Mérillon, JM
    [J]. ANALYTICA CHIMICA ACTA, 2002, 458 (01) : 103 - 110