Experimental Results and Modeling of Low-Heat-Capacity TES Microcalorimeters for Soft-X-ray Spectroscopy

被引:7
作者
Eckart, Megan E. [1 ]
Adams, Joseph S. [1 ]
Bandler, Simon R. [1 ]
Brekosky, Regis P. [1 ]
Chervenak, James A. [1 ]
Finkbeiner, Fred M. [1 ]
Kelley, Richard L. [1 ]
Kilbourne, Caroline A. [1 ]
Porter, F. Scott [1 ]
Sadleir, John E. [1 ]
Smith, Stephen J. [1 ]
机构
[1] NASA, Goddard Space Flight Ctr, Greenbelt, MD 20771 USA
来源
LOW TEMPERATURE DETECTORS LTD 13 | 2009年 / 1185卷
关键词
microcalorimeters; low-temperature detectors; transition-edge sensors; x-ray spectroscopy; ABSORBER DESIGN; LINES; SPECTROMETER;
D O I
10.1063/1.3292370
中图分类号
O59 [应用物理学];
学科分类号
摘要
Transition-edge-sensor (TES) X-ray microcalorimeters have mostly been targeted at mid-band energies from 0.05 - 10 keV and high energies to above 100 keV. However, many other optimizations are possible. Here we present results from devices optimized for soft X-ray applications. For spectroscopy below 1 keV, the X-ray stopping power and heat capacity (C) of the TES itself are high enough that we can omit a separate absorber. The resulting devices have low C and the best-achievable energy resolution should be under 1 eV. We are interested in pursuing such devices primarily for astrophysical applications and laboratory astrophysics at LLNL's Electron-Beam Ion Trap. To this end, we have studied arrays in which 'bare' TESs are interspersed with broad-band pixels that have absorbers. By extending the absorbers to cover the area where the leads contact the low-energy pixels, we have eliminated a significant source of non-Gaussian detector response. The bare devices are in a different regime from our typical devices in that C is ten times lower and the conductance to the bath is four times lower. We have explored this regime through simultaneous fitting of noise and impedance data. These data cannot be fit by the simple model we employ to describe our typical broad-band devices. In this contribution we present X-ray spectra and the results from modeling.
引用
收藏
页码:430 / 433
页数:4
相关论文
共 16 条
[1]   Performance of TES X-ray microcalorimeters with a novel absorber design [J].
Bandler, S. R. ;
Brekosky, R. P. ;
Brown, A. -D. ;
Chervenak, J. A. ;
Figueroa-Feliciano, E. ;
Finkbeiner, F. M. ;
Iyomoto, N. ;
Kelley, R. L. ;
Kilbourne, C. A. ;
Porter, F. S. ;
Sadleir, J. ;
Smith, S. J. .
JOURNAL OF LOW TEMPERATURE PHYSICS, 2008, 151 (1-2) :400-405
[2]   DIAGRAM AND NONDIAGRAM LINES IN K SPECTRA OF ALUMINUM AND OXYGEN FROM METALLIC AND ANODIZED ALUMINUM [J].
FISCHER, DW ;
BAUN, WL .
JOURNAL OF APPLIED PHYSICS, 1965, 36 (02) :534-&
[3]  
GOLDIE DJ, 2008, P SPIE, V7020
[4]   Close-packed arrays of transition-edge x-ray microcalorimeters with high spectral resolution at 5.9 keV [J].
Iyomoto, N. ;
Bandler, S. R. ;
Brekosky, R. P. ;
Brown, A. -D. ;
Chervenak, J. A. ;
Finkbeiner, F. M. ;
Kelley, R. L. ;
Kilbourne, C. A. ;
Porter, F. S. ;
Sadleir, J. E. ;
Smith, S. J. ;
Figueroa-Feliciano, E. .
APPLIED PHYSICS LETTERS, 2008, 92 (01)
[5]   Modeling of TES X-ray microcalorimeters with a novel absorber design [J].
Iyomoto, N. ;
Bandler, S. R. ;
Brekosky, R. P. ;
Brown, A. -D. ;
Chervenak, J. A. ;
Figueroa-Feliciano, E. ;
Finkbeiner, F. M. ;
Kelley, R. L. ;
Kilbourne, C. A. ;
Lindeman, M. A. ;
Porter, F. S. ;
Saab, T. ;
Sadleir, J. E. ;
Smith, S. J. .
JOURNAL OF LOW TEMPERATURE PHYSICS, 2008, 151 (1-2) :406-412
[6]   Heat Capacity of Absorbers for Transition-Edge Sensors Suitable for Space-Borne Far-IR/Submm Spectroscopy [J].
Kenyon, M. ;
Day, P. K. ;
Bradford, C. M. ;
Bock, J. J. ;
Leduc, H. G. .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2009, 19 (03) :524-527
[7]  
Kenyon M., 2006, P SPIE, V6275
[8]   Various optimizations of TES arrays for X-ray astrophysics [J].
Kilbourne, C. A. ;
Bandler, S. R. ;
Brown, A. -D. ;
Chervenak, A. ;
Figueroa-Feliciano, E. ;
Finkbeiner, F. ;
Iyomoto, N. ;
Kelley, R. L. ;
Porter, F. S. ;
Smith, S. J. .
JOURNAL OF LOW TEMPERATURE PHYSICS, 2008, 151 (1-2) :223-228
[9]   NATURAL WIDTHS OF ATOMIC K-LEVELS AND L-LEVELS,K-ALPHA X-RAY-LINES AND SEVERAL KLL AUGER LINES [J].
KRAUSE, MO ;
OLIVER, JH .
JOURNAL OF PHYSICAL AND CHEMICAL REFERENCE DATA, 1979, 8 (02) :329-338
[10]   Characterization and reduction of noise in Mo/Au transition edge sensors [J].
Lindeman, MA ;
Bandler, S ;
Brekosky, RP ;
Chervenak, JA ;
Figueroa-Feliciano, E ;
Finkbeiner, FM ;
Saab, T ;
Stahle, CK .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 520 (1-3) :348-350