Determination of inorganic mercury and total mercury in biological and environmental samples by flow injection-cold vapor-atomic absorption spectrometry using sodium borohydride as the sole reducing agent

被引:1
作者
Segade, SR
Tyson, JF
机构
[1] Univ Vigo, Dept Quim Analit & Alimentaria, Fac Ciencias Quim, Vigo, Spain
[2] Univ Massachusetts, Dept Chem, Amherst, MA 01003 USA
关键词
flow injection; inorganic mercury; total mercury; water; biological samples; sediment; microwave-assisted extraction;
D O I
暂无
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A simple, fast, precise and accurate method to determine inorganic mercury and total mercury in biological and environmental samples was developed. The optimized flow-injection mercury system permitted the separate determination of inorganic mercury and total mercury using sodium borohydride as reducing agent. Inorganic mercury was selectively determined after reduction with 10(-4)% w/v sodium borohydride, while total mercury was determined after reduction with 0.75% w/v sodium borohydride. The calibration graphs were linear up to 30 ng ml(-1). The detection limits of the method based on three times the standard deviation of the blank were 24 and 3.9 ng l(-1) for,total mercury and inorganic mercury determination, respectively. The relative standard deviation was less than 1.5% for a 10 ng ml(-1) mercury standard. As a means of checking method performance, deionized water and pond water samples were spiked with methylmercury and inorganic mercury; quantitative recovery for total mercury and inorganic mercury was obtained. The accuracy of the method was verified by analyzing alkaline and acid extracts of five biological and sediment reference materials. Microwave-assisted extraction procedures resulted in higher concentrations of recovered mercury species, lower matrix interference with mercury determination and less time involved in sample treatment than conventional extraction procedures. The standard addition method was only needed for calibration when biological samples were analyzed. The detection limits were in the range of 1.2-19 and 6.6-18 ng g(-1) in biological and sediment samples for inorganic mercury and total mercury determination, respectively. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:797 / 807
页数:11
相关论文
共 25 条
[1]   AUTOMATED CONTINUOUS MONITORING OF INORGANIC AND TOTAL MERCURY IN WASTE-WATER AND OTHER WATERS BY FLOW-INJECTION ANALYSIS AND COLD-VAPOR ATOMIC-ABSORPTION SPECTROMETRY [J].
BIRNIE, SE .
JOURNAL OF AUTOMATIC CHEMISTRY, 1988, 10 (03) :140-143
[2]   The use of emulsions for the determination of methylmercury and inorganic mercury in fish-eggs oil by cold vapor generation in a flow injection system with atomic absorption spectrometric detection [J].
Burguera, JL ;
Quintana, IA ;
Salager, JL ;
Burguera, M ;
Rondón, C ;
Carrero, P ;
de Salager, RA ;
de Peña, YP .
ANALYST, 1999, 124 (04) :593-599
[3]   Room temperature sonolysis-based advanced oxidation process for degradation of organomercurials: Application to determination of inorganic and total mercury in waters by flow injection-cold vapor atomic absorption spectrometry [J].
Capelo, JL ;
Lavilla, I ;
Bendicho, C .
ANALYTICAL CHEMISTRY, 2000, 72 (20) :4979-4984
[4]  
Chen HP, 1998, ATOM SPECTROSC, V19, P176
[5]   The toxicology of mercury [J].
Clarkson, TW .
CRITICAL REVIEWS IN CLINICAL LABORATORY SCIENCES, 1997, 34 (04) :369-403
[6]  
CRAIG PJ, 1986, ORGANOMETALLIC COMPO, P65
[7]   MERCURY-CYCLING IN SURFACE WATERS AND IN THE ATMOSPHERE - SPECIES ANALYSIS FOR THE INVESTIGATION OF TRANSFORMATION AND TRANSPORT-PROPERTIES OF MERCURY [J].
EBINGHAUS, R ;
HINTELMANN, H ;
WILKEN, RD .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 350 (1-2) :21-29
[8]  
EL-AWADY A A, 1976, Analytical Chemistry, V48, P110, DOI 10.1021/ac60365a051
[9]   METHYLMERCURY DETERMINATION AS VOLATILE METHYLMERCURY HYDRIDE BY PURGE AND TRAP GAS-CHROMATOGRAPHY IN LINE WITH FOURIER-TRANSFORM INFRARED-SPECTROSCOPY [J].
FILIPPELLI, M ;
BALDI, F ;
BRINCKMAN, FE ;
OLSON, GJ .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1992, 26 (07) :1457-1460
[10]   A time-based flow injection cold vapor atomic absorption spectrometry system with on-line microwave sample pre-treatment for the determination of inorganic and total mercury in urine [J].
Gallignani, M ;
Bahsas, H ;
Brunetto, MR ;
Burguera, M ;
Burguera, JL ;
de Peña, YP .
ANALYTICA CHIMICA ACTA, 1998, 369 (1-2) :57-67