Quasi-real-time imaging using ultrasonic Fourier transform camera

被引:0
|
作者
Honda, T [1 ]
Honda, Y [1 ]
Ikeda, M [1 ]
Nakajima, M [1 ]
机构
[1] Keio Univ, Fac Sci & Technol, Yokohama, Kanagawa 2230061, Japan
来源
ELECTRONICS AND COMMUNICATIONS IN JAPAN PART III-FUNDAMENTAL ELECTRONIC SCIENCE | 2001年 / 84卷 / 05期
关键词
object image reproduction; ultrasound; holography; Fourier transform;
D O I
10.1002/1520-6440(200105)84:5<53::AID-ECJC6>3.0.CO;2-U
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper proposes an imaging method using ultrasound for objects which cannot be observed optically, such as objects in muddy water or in mist. The acoustic Fourier transform (AFT) is described, whereby the object information is Fourier-transformed using the ultrasound. A transmitter element and a number of receiver elements are placed on the transmitter-receiver plane. The object and the reference sound source are placed on the front side, so that they are located on a circle, with the distance between the object and the transmitter-receiver plane as the diameter. Then, the interference pattern between the reflected wave from the object and the reference wave contains the Fourier-transform information of the object on the receiver plane. The obtained interference pattern is fed into a computer. Executing the inverse transform using the fast Fourier transform (FFT) program, the image of the object is immediately reproduced. In the system proposed in this paper, the reference wave is constructed in the computer, instead of actually placing the reference source, and the reference wave is added electrically to the received signal. The object at an arbitrary distance can be imaged, by adjusting the curvature of the reference wave, based on the distance from the transmitter-receiver plane to the object measured by the pulse-echo method. The design parameters for the experimental system are determined by computer simulation, and an experimental system was constructed. The effectiveness of the proposed method was demonstrated by a computer simulation and a simple object reproduction experiment, which were conducted to examine the effectiveness of the proposed reproduction method. (C) 2001 Scripta Technica.
引用
收藏
页码:53 / 61
页数:9
相关论文
共 50 条
  • [41] Analysis of atrial and ventricular premature contractions using the Short Time Fourier Transform with the window size fixed in the frequency domain
    Mateo, Carlos
    Talavera, Juan Antonio
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2021, 69
  • [42] Discussion on real-time imaging technology using hybrid optoelectronic processor
    Qian, Chao
    Li, Yongqing
    AGRO FOOD INDUSTRY HI-TECH, 2017, 28 (01): : 1857 - 1861
  • [43] Ultrasonic Bubble Imaging in Molten Salt Using a Multi-Mode Waveguide and Time Reversal
    Grueter, Lars
    Nauber, Richard
    Czarske, Juergen W.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [44] Forecasting Stock Market Indices Using Padding-Based Fourier Transform Denoising and Time Series Deep Learning Models
    Song, Donghwan
    Baek, Adrian Matias Chung
    Kim, Namhun
    IEEE ACCESS, 2021, 9 : 83786 - 83796
  • [45] Ultrasound based glass fragments detection in glass containers filled with beverages using neural networks and short time Fourier transform
    Zhao, B.
    Yang, P.
    Basir, O. A.
    Mittal, G. S.
    FOOD RESEARCH INTERNATIONAL, 2006, 39 (06) : 686 - 695
  • [46] Real-Time Control of Nanoparticle-Mediated Thermal Therapy Using Photoacoustic Imaging
    Assi, Hisham
    Yang, Celina
    Shaswary, Elyas
    Tam, Mareck
    Tavakkoli, Jahan
    Kolios, Michael
    Peyman, Gholam
    Kumaradas, Carl
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2021, 68 (07) : 2188 - 2194
  • [47] Real-Time Ultrasound Detection of Breast Microcalcifications Using Multifocus Twinkling Artifact Imaging
    Kang, Jinbum
    Han, Kanghee
    Song, Ilseob
    Kim, Kang-Sik
    Jang, Won Seuk
    Kim, Min Jung
    Yoo, Yangmo
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2022, 41 (05) : 1300 - 1308
  • [48] Teaching real-time ultrasonic imaging with a 4-channel sonar array, TI C6711 DSK and MATLAB
    York, GWP
    Welch, TB
    Wright, CHG
    BIOMEDICAL SCIENCES INSTRUMENTATION, VOL 41, 2005, 41 : 370 - 375
  • [49] Non-invasive real-time imaging of atherosclerosis in mice using ultrasound biomicroscopy
    Gan, Li-ming
    Gronros, Julia
    Hagg, Ulrika
    Wikstrom, Johannes
    Theodoropoulos, Catherine
    Friberg, Peter
    Fritsche-Danielson, Regina
    ATHEROSCLEROSIS, 2007, 190 (02) : 313 - 320
  • [50] Real-time H-scan ultrasound imaging using a Verasonics research scanner
    Khairalseed, Mawia
    Brown, Katherine
    Parker, Kevin J.
    Hoyt, Kenneth
    ULTRASONICS, 2019, 94 : 28 - 36