摘要
There is still a lack of approaches for quantitative depth-profiling when dealing with glow discharges (GD) coupled to mass spectrometric detection. The purpose of this work is to develop quantification procedures using pulsed GD (PGD) - time of flight mass spectrometry. In particular, research was focused towards the depth profile analysis of Cu/NiCu nanolayers and multilayers electrodeposited on Si wafers. PGDs are characterized by three different regions due to the temporal application of power: prepeak, plateau and afterglow. This last region is the most sensitive and so it is convenient for quantitative analysis of minor components; however, major elements are often saturated, even at 30 W of applied radiofrequency power for these particular samples. For such cases, we have investigated two strategies based on a multimatrix calibration procedure: (i) using the afterglow region for all the sample components except for the major element (Cu) that was analyzed in the plateau, and (ii) using the afterglow region for all the elements measuring the ArCu signal instead of Cu. Seven homogeneous certified reference materials containing Si, Cr, Fe, Co, Ni and Cu have been used for quantification. Quantitative depth profiles obtained with these two strategies for samples containing 3 or 6 multilayers (of a. few tens of nanometers each layer) were in agreement with the expected values, both in terms of thickness and composition of the layers. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:34 / 41
页数:8
相关论文
共 26 条
  • [1] Depth Profile Analysis of Amorphous Silicon Thin Film Solar Cells by Pulsed Radiofrequency Glow Discharge Time of Flight Mass Spectrometry
    Alvarez-Toral, Aitor
    Sanchez, Pascal
    Menendez, Armando
    Pereiro, Rosario
    Sanz-Medel, Alfredo
    Fernandez, Beatriz
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2015, 26 (02) : 305 - 314
  • [2] Pulsed radiofrequency glow discharge time of flight mass spectrometry for coated glass analysis
    Bouza, Marcos
    Pereiro, Rosario
    Bordel, Nerea
    Sanz-Medel, Alfredo
    Fernandez, Beatriz
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2015, 30 (05) : 1108 - 1116
  • [3] Magnetic Multilayers as a Way to Increase the Magnetic Field Responsiveness of Magnetocaloric Materials
    Caballero-Flores, R.
    Franco, V.
    Conde, A.
    Kiss, L. F.
    Peter, L.
    Bakonyi, I.
    [J]. JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2012, 12 (09) : 7432 - 7436
  • [4] Depth profile analysis of solar cell silicon by GD-MS
    Di Sabatino, M.
    Modanese, C.
    Arnberg, L.
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (11) : 2072 - 2077
  • [5] Determination of relative sensitivity factors for trace element analysis of solar cell silicon by fast-flow glow discharge mass spectrometry
    Di Sabatino, Marisa
    Dons, Anne L.
    Hinrichs, Joachim
    Arnberg, Lars
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (02) : 144 - 148
  • [6] Compositional depth profiling analysis of thin and ultrathin multilayer coatings by radio-frequency glow discharge optical emission spectroscopy
    Escobar Galindo, R.
    Fornies, E.
    Albella, J. M.
    [J]. SURFACE & COATINGS TECHNOLOGY, 2006, 200 (22-23) : 6185 - 6189
  • [7] Interfacial effects during the analysis of multilayer metal coatings by radio-frequency glow discharge optical emission spectroscopy -: Part 2.: Evaluation of depth resolution function and application to thin multilayer coatings
    Galindo, RE
    Forniés, E
    Albella, JM
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (10) : 1116 - 1120
  • [8] Interfacial effects during the analysis of multilayer metal coatings by radio-frequency glow discharge optical emission spectroscopy -: Part 1.: Crater shape and sputtering rate effects
    Galindo, RE
    Forniés, E
    Albella, JM
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (10) : 1108 - 1115
  • [9] The development of a stable citrate electrolyte for the electrodeposition of copper-nickel alloys
    Green, TA
    Russell, AE
    Roy, S
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1998, 145 (03) : 875 - 881
  • [10] Calibration of double focusing Glow Discharge Mass Spectrometry instruments with pin-shaped synthetic standards
    Gusarova, T.
    Methven, B.
    Kipphardt, H.
    Sturgeon, R.
    Matschat, R.
    Panne, U.
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (11-12) : 847 - 854