Accuracy of PCA-NN in non-invasively determining tissue optical properties from spatially resolved diffuse reflectance

被引:0
作者
Chen, YQ [1 ]
Lin, L [1 ]
Li, G [1 ]
Gao, JM [1 ]
Wu, KJ [1 ]
机构
[1] Tianjin Univ, State Key Lab Precis Measuring Technol & Instrume, Tianjin 300072, Peoples R China
来源
OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS: DIAGNOSTICS AND TREATMENT II , PTS 1 AND 2 | 2005年 / 5630卷
关键词
tissue; optical properties; light reflection; light absorption; light scattering; Monte Carlo methods; computer simulation; neural networks; principal component analysis; measurement errors;
D O I
10.1117/12.568730
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
In this paper, with reference to practical applications, we investigate the accuracy of the PCA-NN method in determining the optical properties mu(a) and mu(s)' from the spatially resolved relative reflectance data produced by Monte Carlo simulations. To test prediction performance of PCA-NN from the reflectance data with different lengths and different measurement noises, we constructed six PCA-NNs respectively corresponding to data length = 5, 10, 15, 20, 25 and 30 mm, which were trained by higher precision reflectance produced with photons = 10(7). Then lower precision reflectance generated with photons = 10(4), 2 x 10(4), 5 x 10(4), 7 x 10(4), 10(5), 2 x 10(5), 5 x 10(5), 7 x 10(5) and 10(6) were inputted to PCA-NNs to extract mu(a) and mu(s)' and the accuracy of mu(a) and mu(s)' was calculated, respectively. The results showed that for the reflectance with the same data length, the prediction errors of mu(a) and mu(s)' increase as the data noise increases; but for the reflectance with the same data precision, the errors decrease as the data length becomes longer. In conclusion, the preliminary results in this paper provide a guideline for choosing appropriate measurement conditions or estimating the prediction errors in reality.
引用
收藏
页码:498 / 509
页数:12
相关论文
共 18 条
[1]  
CHEN Y, 2003, IEEE INT C NEUR NETW, V1, P369
[2]  
CHEN Y, 2004, P SOC PHOTO-OPT INS, V5486, P85
[3]   TIME-RESOLVED REFLECTANCE - A SYSTEMATIC STUDY FOR APPLICATION TO THE OPTICAL CHARACTERIZATION OF TISSUES [J].
CUBEDDU, R ;
MUSOLINO, M ;
PIFFERI, A ;
TARONI, P ;
VALENTINI, G .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 1994, 30 (10) :2421-2430
[4]   Determination of tissue optical properties from diffuse reflectance profiles by multivariate calibration [J].
Dam, JS ;
Andersen, PE ;
Dalgaard, T ;
Fabricius, PE .
APPLIED OPTICS, 1998, 37 (04) :772-778
[5]   Influence of layered tissue architecture on estimates of tissue optical properties obtained from spatially resolved diffuse reflectometry [J].
Farrell, TJ ;
Patterson, MS ;
Essenpreis, M .
APPLIED OPTICS, 1998, 37 (10) :1958-1972
[6]   THE USE OF A NEURAL NETWORK TO DETERMINE TISSUE OPTICAL-PROPERTIES FROM SPATIALLY RESOLVED DIFFUSE REFLECTANCE MEASUREMENTS [J].
FARRELL, TJ ;
WILSON, BC ;
PATTERSON, MS .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (12) :2281-2286
[7]   A DIFFUSION-THEORY MODEL OF SPATIALLY RESOLVED, STEADY-STATE DIFFUSE REFLECTANCE FOR THE NONINVASIVE DETERMINATION OF TISSUE OPTICAL-PROPERTIES INVIVO [J].
FARRELL, TJ ;
PATTERSON, MS ;
WILSON, B .
MEDICAL PHYSICS, 1992, 19 (04) :879-888
[8]  
Hollis V, 2002, NONINVASIVE MONITORI
[9]   Determination of hemoglobin oxygen saturation from turbid media using reflectance spectroscopy with small source-detector separations [J].
Johns, M ;
Giller, CA ;
Liu, HL .
APPLIED SPECTROSCOPY, 2001, 55 (12) :1686-1694
[10]   Determination of the optical properties of semi-infinite turbid media from frequency-domain reflectance close to the source [J].
Kienle, A ;
Patterson, MS .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (09) :1801-1819