Theoretical analysis and optimization of electromagnetic actuation in a valveless microimpedance pump

被引:29
作者
Chang, Hsien-Tsung
Lee, Chia-Yen
Wen, Chih-Yung
Hong, Boe-Shong
机构
[1] Da Yeh Univ, Dept Mech & Automat Engn, Changhua 515, Taiwan
[2] Natl Cheng Kung Univ, Dept Aeronaut & Astronaut, Tainan 701, Taiwan
[3] Natl Chung Cheng Univ, Dept Mech Engn, Chiayi 621, Taiwan
关键词
electromagnetic actuator; Liebau phenomenon; microelectro mechanical system (MEMS); PDMS diaphragm; valveless microimpedance pump;
D O I
10.1016/j.mejo.2007.04.013
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The construction of a novel valveless microimpedance pump is proposed and the utilized electromagnetic actuator is designed and optimized in this study. The actuating mechanism comprises an electroplated permanent magnet mounted on a flexible PDMS diaphragm and electroplated Cu coils located on a glass substrate. The electromagnetic force between the magnet and the Cu coils causes the diaphragm to deflect and then creates the accumulative effects of wave propagation and reflection at the junction of the compressible and rigid sections. The resulting pressure gradient in the fluid drives the flow from the inlet to the outlet of the micropump. The constituent parts of the electromagnetic actuator, namely the diaphragm, the microcoils, and the magnet are modeled and analyzed in order to optimize the actuator design. The design models are verified both theoretically and numerically and the relationships between the magnetic force, diaphragm displacement, and diaphragm strength are established. The magnitude of the magnetic force acting on the flexible diaphragm are calculated using Ansoft/Maxwell3D FEA software and the resulting diaphragm deflection simulated by ANSYS FEA software are found to agree with the theoretical predictions. Different diaphragm shapes are investigated and their relative strength and flexibility are compared. It is found that a circular PDMS diaphragm represents the most appropriate choice for the actuating mechanism in the micropump. The desired diaphragm deflection of 15 mu m is obtained using a compression force of 16 mu N, generated by a coil input current of 0.9 A. The diaphragm deflection can be regulated by varying the current passed through the microcoil and hence the flow rate can be controlled. The valveless microimpedance Pump proposed in this study is easily fabricated and can be readily integrated with existing biomedical chips due to its plane structure. The results of the present study provide a valuable contribution to the ongoing development of Lab-on-a Chip systems. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:791 / 799
页数:9
相关论文
共 22 条
  • [1] A valve-less diffuser micropump for microfluidic analytical systems
    Andersson, H
    van der Wijngaart, W
    Nilsson, P
    Enoksson, P
    Stemme, G
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2001, 72 (03) : 259 - 265
  • [2] A two-stage discrete peristaltic micropump
    Berg, JM
    Anderson, R
    Anaya, M
    Lahlouh, B
    Holtz, M
    Dallas, T
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2003, 104 (01) : 6 - 10
  • [3] Numerical investigation of the Liebau phenomenon
    Borzì, A
    Propst, G
    [J]. ZEITSCHRIFT FUR ANGEWANDTE MATHEMATIK UND PHYSIK, 2003, 54 (06): : 1050 - 1072
  • [4] CHEN WF, 1995, PLASTICITY STRUCTURA
  • [5] A photocurable poly(dimethylsiloxane) chemistry designed for soft lithographic molding and printing in the nanometer regime
    Choi, KM
    Rogers, JA
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (14) : 4060 - 4061
  • [6] A thermopneumatic dispensing micropump
    Cooney, CG
    Towe, BC
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2004, 116 (03) : 519 - 524
  • [7] Design, optimization and simulation on microelectromagnetic pump
    Gong, QL
    Zhou, ZY
    Yang, YH
    Wang, XH
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2000, 83 (1-3) : 200 - 207
  • [8] GROOM J, 1998, 104229 NASA
  • [9] Investigation for the operation of an integrated peristaltic micropump
    Husband, B
    Bu, M
    Evans, AGR
    Melvin, T
    [J]. JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2004, 14 (09) : S64 - S69
  • [10] Micronozzle/diffuser flow and its application in micro valveless pumps
    Jiang, XN
    Zhou, ZY
    Huang, XY
    Li, Y
    Yang, Y
    Liu, CY
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 1998, 70 (1-2) : 81 - 87