The electrochemical behaviour of ferrocene in a photocurable poly(methyl methacrylate-co-2-hydroxylethyl methacrylate) film for a glucose biosensor

被引:27
作者
Bean, LS [1 ]
Heng, LY [1 ]
Yamin, BM [1 ]
Ahmad, M [1 ]
机构
[1] Univ Kebangsaan Malaysia, Fac Sci & Technol, Sch Chem Sci & Food Technol, Bangi 43600, Selangor, Malaysia
关键词
photocurable; methacrylate polymers; ferrocene; immobilization; glucose biosensor;
D O I
10.1016/j.bioelechem.2004.11.003
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A single-step fabrication of a glucose biosensor with simultaneous immobilization of both ferrocene mediator and glucose oxidase in a photocurable methacrylic film consisting of poly(methyl methacrylate-co-2-hydroxylethyl methacrylate) was reported. The entrapped ferrocene showed reversible redox behaviour in the photocured film and no significant leaching of both entrapped ferrocene and enzyme glucose oxidase was observed because of the low water absorption properties of the co-polymer films. From electrochemical studies, ferrocene entrapped in the co-polymer film demonstrated slow diffusion properties. A linear glucose response range of 2-11 mM was obtained at low applied potential of +0.25 V The glucose biosensor fabricated by this photocuring method yielded sensor reproducibility and repeatability with relative standard deviation of < 10% and long-term stability of up to 14 days. The main advantage of the use of photocurable procedure is that biosensor membrane fabrication can be performed in a single step without any lengthy chemical immobilization of enzyme. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:157 / 162
页数:6
相关论文
共 17 条
[1]  
Armada MPG, 2003, SENSOR ACTUAT B-CHEM, V88, P190, DOI 10.1016/S0925-4005(02)00326-X
[2]   Covalent immobilisation of invertase onto a reactive film composed of 2-hydroxyethyl methacrylate and glycidyl methacrylate:: properties and application in a continuous flow system [J].
Bayramoglu, G ;
Akgöl, S ;
Bulut, A ;
Denizli, A ;
Arica, MY .
BIOCHEMICAL ENGINEERING JOURNAL, 2003, 14 (02) :117-126
[3]   CHARACTERIZATION OF A FERROCENE CONTAINING POLYACRYLAMIDE-BASED REDOX GEL FOR BIOSENSOR USE [J].
BU, HZ ;
MIKKELSEN, SR ;
ENGLISH, AM .
ANALYTICAL CHEMISTRY, 1995, 67 (22) :4071-4076
[4]   ENZYME CATALYSIS AT HYDROGEL-MODIFIED ELECTRODES WITH REDOX POLYMER MEDIATOR [J].
CALVO, EJ ;
DANILOWICZ, C ;
DIAZ, L .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1993, 89 (02) :377-384
[5]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[6]   MEDIATED AMPEROMETRIC BIOSENSORS FOR D-GALACTOSE, GLYCOLATE AND L-AMINO-ACIDS BASED ON A FERROCENE-MODIFIED CARBON PASTE ELECTRODE [J].
DICKS, JM ;
ASTON, WJ ;
DAVIS, G ;
TURNER, APF .
ANALYTICA CHIMICA ACTA, 1986, 182 :103-112
[7]   IMMOBILIZATION OF GLUCOSE-OXIDASE IN FERROCENE-MODIFIED PYRROLE POLYMERS [J].
FOULDS, NC ;
LOWE, CR .
ANALYTICAL CHEMISTRY, 1988, 60 (22) :2473-2478
[8]   A NEW CLASS OF AMPEROMETRIC BIOSENSOR INCORPORATING A POLYMERIC ELECTRON-TRANSFER MEDIATOR [J].
HALE, PD ;
INAGAKI, T ;
KARAN, HI ;
OKAMOTO, Y ;
SKOTHEIM, TA .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1989, 111 (09) :3482-3484
[9]   Assessing a photocured self-plasticised acrylic membrane recipe for Na+ and K+ ion selective electrodes [J].
Heng, LY ;
Hall, EAH .
ANALYTICA CHIMICA ACTA, 2001, 443 (01) :25-40
[10]   Producing "self-plasticizing" ion-selective membranes [J].
Heng, LY ;
Hall, EAH .
ANALYTICAL CHEMISTRY, 2000, 72 (01) :42-51