Calibration and Accuracy Analysis of a Low-Cost Mapping-Grade Mobile Laser Scanning System

被引:23
作者
Hauser, Darren [1 ]
Glennie, Craig [1 ]
Brooks, Benjamin [2 ,3 ]
机构
[1] Univ Houston, Dept Civil & Environm Engn, N107 Engn Bldg 1, Houston, TX 77004 USA
[2] Univ Hawaii, Sch Ocean & Earth Sci & Technol, 1680 East West Rd, Honolulu, HI 96822 USA
[3] US Geol Survey, Earthquake Sci Ctr, 345 Middlefield Rd MS 977, Menlo Pk, CA 94025 USA
基金
美国国家科学基金会;
关键词
Mobile laser scanning; Terrestrial laser scanning; Lidar; Global navigation satellite system (GNSS); inertial navigation system (INS) integration; Accuracy analysis; VELODYNE HDL-64E S2; PERFORMANCE;
D O I
10.1061/(ASCE)SU.1943-5428.0000178
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The calibration and accuracy analysis of a novel, low-cost, adaptable mobile laser scanning (MLS) system using a Velodyne HDL-32E laser scanner and an Oxford Technical Solutions Inertial+2 inertial navigation system, is described. First, a static calibration of the laser scanner is discussed. The static calibration is shown to improve the overall relative accuracy of point cloud data from the scanner by approximately 20% over the manufacturer-supplied calibration. Then, the determination of system boresight angles and lever-arm offsets using a planar patch least-squares approach is presented. Finally, the calibrated and boresighted MLS is operated in a backpack mode to acquire multiple data sets in an area that contains dense ground control acquired using static terrestrial laser scanning (TLS) and a high-end, survey-grade MLS. The dense ground control is used to examine several methods of estimating the overall errors of the backpack MLS system. Detailed comparison of the MLS data with the TLS and survey-grade MLS control shows that, despite the system's low cost, it is able to reliably collect point cloud data with greater than 10-cm three-dimensional root-mean-square error accuracy. (C) 2016 American Society of Civil Engineers.
引用
收藏
页数:9
相关论文
共 24 条
[1]  
[Anonymous], 2013, EOS T AM GEOPHYS UNI, DOI [10.1002/2013EO360002, DOI 10.1002/2013EO360002]
[2]   Geometric validation of a ground-based mobile laser scanning system [J].
Barber, David ;
Mills, Jon ;
Smith-Voysey, Sarah .
ISPRS JOURNAL OF PHOTOGRAMMETRY AND REMOTE SENSING, 2008, 63 (01) :128-141
[3]   Compact Multipurpose Mobile Laser Scanning System - Initial Tests and Results [J].
Glennie, Craig ;
Brooks, Benjamin ;
Ericksen, Todd ;
Hauser, Darren ;
Hudnut, Kenneth ;
Foster, James ;
Avery, Jon .
REMOTE SENSING, 2013, 5 (02) :521-538
[4]   Calibration and Kinematic Analysis of the Velodyne HDL-64E S2 Lidar Sensor [J].
Glennie, Craig .
PHOTOGRAMMETRIC ENGINEERING AND REMOTE SENSING, 2012, 78 (04) :339-347
[5]   Temporal Stability of the Velodyne HDL-64E S2 Scanner for High Accuracy Scanning Applications [J].
Glennie, Craig ;
Lichti, Derek D. .
REMOTE SENSING, 2011, 3 (03) :539-553
[6]   Static Calibration and Analysis of the Velodyne HDL-64E S2 for High Accuracy Mobile Scanning [J].
Glennie, Craig ;
Lichti, Derek D. .
REMOTE SENSING, 2010, 2 (06) :1610-1624
[7]   Kinematic Terrestrial Light-Detection and Ranging System for Scanning [J].
Glennie, Craig .
TRANSPORTATION RESEARCH RECORD, 2009, (2105) :135-141
[8]   Rigorous 3D error analysis of kinematic scanning LIDAR systems [J].
Glennie, Craig .
JOURNAL OF APPLIED GEODESY, 2007, 1 (03) :147-157
[9]  
Haala N., 2008, Int. Arch. Photogramm. Remote Sens. Spat. Inf. Sci, V37, P1119
[10]  
Hunter G., 2006, Int. Arch. Photogramm. Remote Sens. Spat. Inf. Sci, V36