High-speed ion-exclusion chromatography of dissolved carbon dioxide on a small weakly acidic cation-exchange resin column with ion-exchange enhancement columns of conductivity detection

被引:19
|
作者
Mori, M
Ikedo, M
Hu, WZ
Helaleh, MIH
Xu, Q
Itabashi, H
Tanaka, K
机构
[1] Gunma Univ, Fac Engn, Kiryu, Gumma, Japan
[2] Chubu Univ, Grad Sch Engn, Kasugai, Aichi 4878501, Japan
[3] Hokkaido Univ, Grad Sch Environm Earth Sci, Sapporo, Hokkaido 0600810, Japan
[4] Kuwait Inst Sci Res, CAL, Safat 13109, Kuwait
[5] Dionex China Ltd, Shanghai 200021, Peoples R China
[6] Natl Inst & Adv Ind Sci & Technol, Aichi 4890884, Japan
关键词
water analysis; ion-exclusion chromatography; dissolved carbon dioxide; conductivity; ion-exchange; calibration linearity;
D O I
10.1016/j.chroma.2005.08.060
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The high-speed ion-exclusion chromatographic determination of dissolved carbon dioxide, i.e., carbonic acid, hydrogencarbonate or carbonate, with conductivity detection was obtained using a small column packed with a weakly acidic cation-exchange resin in the H+-form (40 mm long x 4.6 mm i.d., 3 mu m-particle and 0.1 meq./ml-capacity). Two different ion-exchange resin columns, which were a strongly acidic cation-exchange resin in the K+-form and a strongly basic anion-exchange resin in the OH--form, were connected after the separation column. The sequence of columns could convert dissolved carbon dioxide to KOH having high conductivity response. The enhancement effect for dissolved carbon dioxide could retain even on the vast chromatographic runs, by using the enhancement columns with high ion-exchange capacity above 1.0 meq./ml. The retention time was in 60 s at flow-rate of 1.2 ml/min. The calibration graph of dissolved carbon dioxide estimated as H2CO3- was linear in the range of 0.005-10 mM. The detection limit at signal to noise of 3 was 0.15 mu M as H2CO3-. This method was applicable to several rainwater and tap water samples. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:250 / 253
页数:4
相关论文
共 49 条
  • [21] ELUTION BEHAVIOR OF ACIDS IN ION-EXCLUSION CHROMATOGRAPHY USING A CATION-EXCHANGE RESIN
    TANAKA, K
    ISHIZUKA, T
    SUNAHARA, H
    JOURNAL OF CHROMATOGRAPHY, 1979, 174 (01): : 153 - 157
  • [22] Selective determination of ammonium ions by high-speed ion-exclusion chromatography on a weakly basic anion-exchange resin column
    Mori, M
    Tanaka, K
    Helaleh, MIH
    Xu, Q
    Ikedo, M
    Ogura, Y
    Sato, S
    Hu, WZ
    Hasebe, K
    JOURNAL OF CHROMATOGRAPHY A, 2003, 997 (1-2) : 191 - 197
  • [23] Ion-exclusion chromatography with conductimetric detection of aliphatic carboxylic acids on a weakly acidic cation-exchange resin by elution with benzoic acid-β-cyclodextrin
    Tanaka, K
    Mori, M
    Xu, Q
    Helaleh, MIH
    Ikedo, M
    Taoda, H
    Hu, WZ
    Hasebe, K
    Fritz, JS
    Haddad, PR
    JOURNAL OF CHROMATOGRAPHY A, 2003, 997 (1-2) : 127 - 132
  • [24] Ion-exclusion chromatography of silicate ion in sea and river water samples by an ion-exchange enhancement of conductivity detection
    Mori, M
    Tanaka, K
    Taoda, H
    Ikedo, M
    Hu, WZ
    BUNSEKI KAGAKU, 2004, 53 (12) : 1481 - 1486
  • [25] Simultaneous ion-exclusion chromatography and cation-exchange chromatography of anions and cations in environmental water samples on a weakly acidic cation-exchange resin by elution with pyridine-2,6-dicarboxylic acid
    Ding, MY
    Tanaka, K
    Hu, WZ
    Hasebe, K
    Haddad, PR
    ANALYST, 2001, 126 (05) : 567 - 570
  • [26] Ion-exclusion chromatography of aliphatic carboxylic acids on a cation-exchange resin by elution with polyvinyl alcohol
    Tanaka, K
    Ohta, K
    Fritz, JS
    JOURNAL OF CHROMATOGRAPHY A, 1997, 770 (1-2) : 211 - 218
  • [27] Separation of aliphatic carboxylic acids and benzenecarboxylic acids by ion-exclusion chromatography with various cation-exchange resin columns and sulfuric acid as eluent
    Ohta, K
    Ohashi, M
    Jin, JY
    Takeuchi, T
    Fujimoto, C
    Choi, SH
    Ryoo, JJ
    Lee, KP
    JOURNAL OF CHROMATOGRAPHY A, 2003, 997 (1-2) : 117 - 125
  • [28] EXPERIMENTAL STUDY OF RESIN DESIGN FOR HIGH-SPEED ION-EXCHANGE CHROMATOGRAPHY
    HANSEN, LC
    GILBERT, TW
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1974, 12 (08) : 458 - 463
  • [29] ION-EXCLUSION CHROMATOGRAPHY WITH CONDUCTIMETRIC DETECTION OF ALIPHATIC CARBOXYLIC-ACIDS ON AN H+-FORM CATION-EXCHANGE RESIN COLUMN BY ELUTION WITH POLYOLS AND SUGARS
    TANAKA, K
    OHTA, K
    FRITZ, JS
    LEE, YS
    SHIM, SB
    JOURNAL OF CHROMATOGRAPHY A, 1995, 706 (1-2) : 385 - 393
  • [30] Use of a Polystyrene-divinylbenzene-based Weakly Acidic Cation-Exchange Resin Column and Propionic Acid as an Eluent in Ion-Exclusion/Adsorption Chromatography of Aliphatic Carboxylic Acids and Ethanol in Food Samples
    Mori, Masanobu
    Hironaga, Takahiro
    Kajiwara, Hiroe
    Nakatani, Nobutake
    Kozaki, Daisuke
    Itabashi, Hideyuki
    Tanaka, Kazuhiko
    ANALYTICAL SCIENCES, 2011, 27 (05) : 505 - 510