High-speed ion-exclusion chromatography of dissolved carbon dioxide on a small weakly acidic cation-exchange resin column with ion-exchange enhancement columns of conductivity detection

被引:19
|
作者
Mori, M
Ikedo, M
Hu, WZ
Helaleh, MIH
Xu, Q
Itabashi, H
Tanaka, K
机构
[1] Gunma Univ, Fac Engn, Kiryu, Gumma, Japan
[2] Chubu Univ, Grad Sch Engn, Kasugai, Aichi 4878501, Japan
[3] Hokkaido Univ, Grad Sch Environm Earth Sci, Sapporo, Hokkaido 0600810, Japan
[4] Kuwait Inst Sci Res, CAL, Safat 13109, Kuwait
[5] Dionex China Ltd, Shanghai 200021, Peoples R China
[6] Natl Inst & Adv Ind Sci & Technol, Aichi 4890884, Japan
关键词
water analysis; ion-exclusion chromatography; dissolved carbon dioxide; conductivity; ion-exchange; calibration linearity;
D O I
10.1016/j.chroma.2005.08.060
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The high-speed ion-exclusion chromatographic determination of dissolved carbon dioxide, i.e., carbonic acid, hydrogencarbonate or carbonate, with conductivity detection was obtained using a small column packed with a weakly acidic cation-exchange resin in the H+-form (40 mm long x 4.6 mm i.d., 3 mu m-particle and 0.1 meq./ml-capacity). Two different ion-exchange resin columns, which were a strongly acidic cation-exchange resin in the K+-form and a strongly basic anion-exchange resin in the OH--form, were connected after the separation column. The sequence of columns could convert dissolved carbon dioxide to KOH having high conductivity response. The enhancement effect for dissolved carbon dioxide could retain even on the vast chromatographic runs, by using the enhancement columns with high ion-exchange capacity above 1.0 meq./ml. The retention time was in 60 s at flow-rate of 1.2 ml/min. The calibration graph of dissolved carbon dioxide estimated as H2CO3- was linear in the range of 0.005-10 mM. The detection limit at signal to noise of 3 was 0.15 mu M as H2CO3-. This method was applicable to several rainwater and tap water samples. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:250 / 253
页数:4
相关论文
共 49 条
  • [1] High-speed simultaneous ion-exclusion/cation-exchange chromatography of anions and cations on a weakly acidic cation-exchange resin column
    Mori, M
    Tanaka, K
    Helaleh, MIH
    Xu, Q
    Ikedo, M
    Ogura, Y
    Sato, S
    Hu, WZ
    Hasebe, K
    Haddad, PR
    JOURNAL OF CHROMATOGRAPHY A, 2003, 997 (1-2) : 219 - 224
  • [2] Vacancy ion-exclusion chromatography of inorganic acids on a weakly acidic cation-exchange resin column
    Mori, Masanobu
    Itabashi, Hideyuki
    Helaleh, Murad I. H.
    Kaczmarski, Krzysztof
    Glod, Bronislaw
    Kowalska, Teresa
    Xu, Qun
    Ikedo, Mikaru
    Hu, Wenzhi
    Tanaka, Kazuhiko
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1118 (01) : 41 - 45
  • [3] Vacancy ion-exclusion chromatography of carboxylic acids on a weakly acidic cation-exchange resin
    Tanaka, K
    Ding, MY
    Helaleh, MIH
    Taoda, H
    Takahashi, H
    Hu, WZ
    Hasebe, K
    Haddad, PR
    Fritz, JS
    Sarzanini, C
    JOURNAL OF CHROMATOGRAPHY A, 2002, 956 (1-2) : 209 - 214
  • [4] Simultaneous determination of anions and cations in natural water by ion-exclusion/cation-exchange chromatography with a weakly acidic cation-exchange resin column
    Lee, KP
    Choi, SH
    Park, YC
    Bae, ZU
    Lee, MS
    Lee, SH
    Chang, HY
    Kwon, SM
    Tanaka, K
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2003, 24 (09) : 1324 - 1328
  • [5] Separation of carboxylic acids on a weakly acidic cation-exchange resin by ion-exclusion chromatography
    Tanaka, K
    Chikara, H
    Hu, WZ
    Hasebe, K
    JOURNAL OF CHROMATOGRAPHY A, 1999, 850 (1-2) : 187 - 196
  • [6] Vacancy ion-exclusion chromatography of haloacetic acids on a weakly acidic cation-exchange resin
    Helaleh, MIH
    Tanaka, K
    Mori, M
    Xu, Q
    Taoda, H
    Ding, MY
    Hu, WZ
    Hasebe, K
    Haddad, PR
    JOURNAL OF CHROMATOGRAPHY A, 2003, 997 (1-2) : 133 - 138
  • [7] Vacancy ion-exclusion chromatography of aromatic carboxylic acids on a weakly acidic cation-exchange resin
    Helaleh, MIH
    Tanaka, K
    Mori, M
    Xu, Q
    Taoda, H
    Ding, MY
    Hu, WZ
    Hasebe, K
    Haddad, PR
    JOURNAL OF CHROMATOGRAPHY A, 2003, 997 (1-2) : 139 - 144
  • [8] High-performance ion-exclusion/cation-exchange chromatography of anions and cations in acid rain waters on a weakly acidic cation-exchange resin
    Tanaka, K
    Ohta, K
    Haddad, PR
    Fritz, JS
    Miyanaga, A
    Hu, WZ
    Hasebe, K
    Lee, KP
    Sarzanini, C
    JOURNAL OF CHROMATOGRAPHY A, 2001, 920 (1-2) : 239 - 245
  • [9] ION-EXCLUSION CHROMATOGRAPHY OF CONDENSED PHOSPHATES ON A CATION-EXCHANGE RESIN
    TANAKA, K
    ISHIZUKA, T
    JOURNAL OF CHROMATOGRAPHY, 1980, 190 (01): : 77 - 83
  • [10] DETERMINATION OF BICARBONATE BY ION-EXCLUSION CHROMATOGRAPHY WITH ION-EXCHANGE ENHANCEMENT OF CONDUCTIVITY DETECTION
    TANAKA, K
    FRITZ, JS
    ANALYTICAL CHEMISTRY, 1987, 59 (05) : 708 - 712