Microfabricated electrochemical sensors for exhaustive coulometry applications

被引:9
作者
Carroll, S. [1 ]
Marei, M. M. [1 ]
Roussel, T. J. [2 ]
Keynton, R. S. [2 ]
Baldwin, R. P. [1 ]
机构
[1] Univ Louisville, Dept Chem, Louisville, KY 40292 USA
[2] Univ Louisville, Dept Bioengn, Louisville, KY 40292 USA
关键词
Exhaustive coulometry; Thin-layer cell; Microfabrication; Electrode array; CELL; TITRATIONS; ARRAY; IONS; CHIP;
D O I
10.1016/j.snb.2011.07.055
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of microfabricated electrochemical systems suitable for deployment in sensor networks that operate with a minimum of operator intervention are of great interest; therefore, a coulometric sensing system for exhaustive coulometry with the potential for calibration-free operation has been designed, fabricated and evaluated to support such development. The sensor chips were microfabricated onto a silicon substrate and contained a variety of specially designed thin-film gold working electrodes (ranging from one to five per chip) and a Ag/AgCl pseudo-reference electrode. A custom flow cell containing fluidic connections and counter electrode chamber was also constructed to integrate the sensor and to create an electrolysis chamber with a fixed volume. Different chip designs were evaluated as exhaustive coulometric sensors in terms of reproducibility and longevity using Fe(CN)(6)(3-/4-) as model analytes. The relative standard deviation (RSD) for a chip tested over a period of 42 days was 5.5% whereas the sensor-to-sensor reproducibility was within 6.3%. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:318 / 326
页数:9
相关论文
共 23 条
  • [1] [Anonymous], 2001, ELECTROCHEMICAL METH
  • [2] Beyond potentiometry: Robust electrochemical ion sensor concepts in view of remote chemical sensing
    Bakker, Eric
    Bhakthavatsalam, Vishnupriya
    Gemene, Kebede L.
    [J]. TALANTA, 2008, 75 (03) : 629 - 635
  • [3] Selective coulometric release of ions from ion selective polymeric membranes for calibration-free titrations
    Bhakthavatsalam, Vishnupriya
    Shvarev, Alexey
    Bakker, Eric
    [J]. ANALYST, 2006, 131 (08) : 895 - 900
  • [4] Self-Calibrating Microfabricated Iridium Oxide pH Electrode Array for Remote Monitoring
    Carroll, Susan
    Baldwin, Richard P.
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (03) : 878 - 885
  • [5] 5-ELECTRODE THIN-LAYER CELL FOR SPECTROELECTROCHEMISTRY APPLIED TO SPECTROCOULOMETRIC TITRATIONS
    CONDIT, DA
    HERRERA, ME
    STANKOVICH, MT
    CURRAN, DJ
    [J]. ANALYTICAL CHEMISTRY, 1984, 56 (14) : 2909 - 2914
  • [6] Improved free chlorine amperometric sensor chip for drinking water applications
    Del Campo, FJ
    Ordeig, O
    Muñoz, FJ
    [J]. ANALYTICA CHIMICA ACTA, 2005, 554 (1-2) : 98 - 104
  • [7] Wireless sensor networks and chemo-/biosensing
    Diamond, Dermot
    Coyle, Shirley
    Scarmagnani, Silvia
    Hayes, Jer
    [J]. CHEMICAL REVIEWS, 2008, 108 (02) : 652 - 679
  • [8] Amperometric enzyme biosensors: Past, present and future
    Dzyadevych, S. V.
    Arkhypova, V. N.
    Soldatkin, A. P.
    El'skaya, A. V.
    Martelet, C.
    Jaffrezic-Renault, N.
    [J]. IRBM, 2008, 29 (2-3) : 171 - 180
  • [9] Coulometric bioelectrocatalytic reactions based on NAD-dependent dehydrogenases in tricarboxylic acid cycle
    Fukuda, Jun
    Tsujimura, Seiya
    Kano, Kenji
    [J]. ELECTROCHIMICA ACTA, 2008, 54 (02) : 328 - 333
  • [10] Background current elimination in thin layer ion-selective membrane coulometry
    Grygolowicz-Pawlak, Ewa
    Bakker, Eric
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2010, 12 (09) : 1195 - 1198