In vivo multiple-mouse MRI at 7 Tesla

被引:74
|
作者
Bock, NA
Nieman, BJ
Bishop, JB
Henkelman, RM
机构
[1] Hosp Sick Children, Mouse Imaging Ctr, Toronto, ON M5G 1X8, Canada
[2] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
关键词
parallel imaging; mouse imaging; phenotyping; mouse models of disease; high field;
D O I
10.1002/mrm.20683
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We developed a live high-field multiple-mouse magnetic resonance imaging method to increase the throughput of imaging studies involving large numbers of mice. Phantom experiments were performed in 7 shielded radiofrequency (RF) coils for concurrent imaging on a 7 Tesla MRI scanner outfitted with multiple transmit and receive channels to confirm uniform signal-to-noise ratio and minimal ghost artifacts across images from the different RF coils. Grid phantoms were used to measure image distortion in different positions in the coils. The brains of 7 live mice were imaged in 3D in the RF coil array, and a second array of 16 RF coils was used to 313 image the whole bodies of 16 fixed, contrast agent-perfused mice. The images of the 7 live mouse brains at 156 mu m isotropic resolution and the 16 whole fixed mice at 100 mu m isotropic resolution were of high quality and free of artifacts. We have thus shown that multiple-mouse MRI increases throughput for live and fixed mouse experiments by a factor equaling the number of RF coils in the scanner.
引用
收藏
页码:1311 / 1316
页数:6
相关论文
共 50 条
  • [41] Transmit and receive transmission line arrays for 7 tesla parallel imaging
    Adriany, G
    Van de Moortele, PF
    Wiesinger, F
    Moeller, S
    Strupp, JP
    Andersen, P
    Snyder, C
    Zhang, XL
    Chen, W
    Pruessmann, KP
    Boesiger, P
    Vaughan, T
    Ugurbil, K
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (02) : 434 - 445
  • [42] Towards intrinsic R2*imaging in the prostate at 3 and 7 tesla
    Luttje, Mariska P.
    van Buuren, Laurens D.
    Luijten, Peter R.
    van Vulpen, Marco
    van der Heide, Uulke A.
    Klomp, Dennis W. J.
    MAGNETIC RESONANCE IMAGING, 2017, 42 : 16 - 21
  • [43] Simple RF design for human functional and morphological cardiac imaging at 7 tesla
    Versluis, M. J.
    Tsekos, N.
    Smith, N. B.
    Webb, A. G.
    JOURNAL OF MAGNETIC RESONANCE, 2009, 200 (01) : 161 - 166
  • [44] A Four-Channel Hole-Slotted Phased Array at 7 Tesla
    Lopez, M. A.
    Ehses, P.
    Breuer, F. A.
    Ponce, I. P.
    Gareis, D.
    Jakob, P. M.
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2010, 37B (04) : 226 - 236
  • [45] GRAPPA reconstructed wave-CAIPI MP-RAGE at 7 Tesla
    Schwarz, Jolanda M.
    Pracht, Eberhard D.
    Brenner, Daniel
    Reuter, Martin
    Stoecker, Tony
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (06) : 2427 - 2438
  • [46] Assessing the Spatial Precision of SE and GE-BOLD Contrast at 7 Tesla
    Panchuelo, Rosa M. Sanchez
    Schluppeck, Denis
    Harmer, Jack
    Bowtell, Richard
    Francis, Susan
    BRAIN TOPOGRAPHY, 2015, 28 (01) : 62 - 65
  • [47] Is the body-coil at 3 Tesla feasible for the MRI evaluation of the painful knee? A comparative study
    G. Lutterbey
    K. Behrends
    M. V. Falkenhausen
    M. P. Wattjes
    N. Morakkabati
    J. Gieseke
    H. Schild
    European Radiology, 2007, 17 : 503 - 508
  • [48] CLINICAL EVALUATION OF STEREOTACTIC TARGET LOCALIZATION USING 3-TESLA MRI FOR RADIOSURGERY PLANNING
    MacFadden, Derek
    Zhang, BeiBei
    Brock, Kristy K.
    Hodaie, Mojgan
    Laperriere, Normand
    Schwartz, Michael
    Tsao, May
    Stainsby, Jeffrey
    Lockwood, Gina
    Mikulis, David
    Menard, Cynthia
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (05): : 1472 - 1479
  • [49] Is the body-coil at 3 Tesla feasible for the MRI evaluation of the painful knee? A comparative study
    Lutterbey, G.
    Behrends, K.
    Falkenhausen, M. V.
    Wattjes, M. P.
    Morakkabati, N.
    Gieseke, J.
    Schild, H.
    EUROPEAN RADIOLOGY, 2007, 17 (02) : 503 - 508
  • [50] 4D cardiac MRI in the mouse
    Feintuch, Akiva
    Zhu, Yonghong
    Bishop, Jonathan
    Davidson, Lorinda
    Dazai, Jun
    Bruneau, Benoit G.
    Henkelman, R. Mark
    NMR IN BIOMEDICINE, 2007, 20 (03) : 360 - 365