In vivo multiple-mouse MRI at 7 Tesla

被引:74
|
作者
Bock, NA
Nieman, BJ
Bishop, JB
Henkelman, RM
机构
[1] Hosp Sick Children, Mouse Imaging Ctr, Toronto, ON M5G 1X8, Canada
[2] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
关键词
parallel imaging; mouse imaging; phenotyping; mouse models of disease; high field;
D O I
10.1002/mrm.20683
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We developed a live high-field multiple-mouse magnetic resonance imaging method to increase the throughput of imaging studies involving large numbers of mice. Phantom experiments were performed in 7 shielded radiofrequency (RF) coils for concurrent imaging on a 7 Tesla MRI scanner outfitted with multiple transmit and receive channels to confirm uniform signal-to-noise ratio and minimal ghost artifacts across images from the different RF coils. Grid phantoms were used to measure image distortion in different positions in the coils. The brains of 7 live mice were imaged in 3D in the RF coil array, and a second array of 16 RF coils was used to 313 image the whole bodies of 16 fixed, contrast agent-perfused mice. The images of the 7 live mouse brains at 156 mu m isotropic resolution and the 16 whole fixed mice at 100 mu m isotropic resolution were of high quality and free of artifacts. We have thus shown that multiple-mouse MRI increases throughput for live and fixed mouse experiments by a factor equaling the number of RF coils in the scanner.
引用
收藏
页码:1311 / 1316
页数:6
相关论文
共 50 条
  • [31] Cerebral Cavernous Hemangiomas at 7 Tesla: Initial Experience
    Schlamann, Marc
    Maderwald, Stefan
    Becker, Wolfgang
    Kraff, Oliver
    Theysohn, Jens M.
    Mueller, Oliver
    Sure, Ulrich
    Wanke, Isabel
    Ladd, Mark E.
    Forsting, Michael
    Schaefer, Lena
    Gizewski, Elke R.
    ACADEMIC RADIOLOGY, 2010, 17 (01) : 3 - 6
  • [32] BI-Ground Microstrip Array Coil vs. Conventional Microstrip Array Coil for Mouse Imaging at 7 Tesla
    Hernandez, Ricardo
    Lopez Terrones, M. A.
    Jakob, P. M.
    MEDICAL PHYSICS, 2012, 1494 : 118 - 120
  • [33] Preliminary report on in vivo coronary MRA at 3 Tesla in humans
    Stuber, M
    Botnar, RM
    Fischer, SE
    Lamerichs, R
    Smink, J
    Harvey, P
    Manning, WJ
    MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (03) : 425 - 429
  • [34] Comparison of multiple sclerosis lesions at 1.5 and 3.0 Tesla
    Sicotte, NL
    Voskuhl, RR
    Bouvier, S
    Klutch, R
    Cohen, MS
    Mazziotta, JC
    INVESTIGATIVE RADIOLOGY, 2003, 38 (07) : 423 - 427
  • [35] Mouse MRI using phased-array coils
    Gareis, Daniel
    Wichmann, Tobias
    Lanz, Titus
    MeIkus, Gerd
    Horn, Michael
    Jakob, Peter M.
    NMR IN BIOMEDICINE, 2007, 20 (03) : 326 - 334
  • [36] Clinical and technical considerations for high quality breast MRI at 3 tesla
    Rahbar, Habib
    Partridge, Savannah C.
    DeMartini, Wendy B.
    Thursten, Bonnie
    Lehman, Constance D.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (04) : 778 - 790
  • [37] Application of a birdcage coil at 3 Tesla to imaging of the human knee using MRI
    Peterson, DM
    Carruthers, CE
    Wolverton, BL
    Meister, K
    Werner, M
    Duensing, GR
    Fitzsimmons, JR
    MAGNETIC RESONANCE IN MEDICINE, 1999, 42 (02) : 215 - 221
  • [38] MRI image enhancement using Biot-Savart law at 3 tesla
    Esin, Yunus Emre
    Alpaslan, Ferda Nur
    TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2017, 25 (04) : 3381 - 3396
  • [39] High-resolution 3D MRI of mouse brain reveals small cerebral structures in vivo
    Natt, O
    Watanabe, T
    Boretius, S
    Radulovic, J
    Frahm, J
    Michaelis, T
    JOURNAL OF NEUROSCIENCE METHODS, 2002, 120 (02) : 203 - 209
  • [40] In vivo demonstration of whole-brain multislice multispoke parallel transmit radiofrequency pulse design in the small and large flip angle regimes at 7 Tesla
    Gras, Vincent
    Vignaud, Alexandre
    Amadon, Alexis
    Mauconduit, Franck
    Le Bihan, Denis
    Boulant, Nicolas
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (03) : 1009 - 1019