In vivo multiple-mouse MRI at 7 Tesla

被引:74
|
作者
Bock, NA
Nieman, BJ
Bishop, JB
Henkelman, RM
机构
[1] Hosp Sick Children, Mouse Imaging Ctr, Toronto, ON M5G 1X8, Canada
[2] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
关键词
parallel imaging; mouse imaging; phenotyping; mouse models of disease; high field;
D O I
10.1002/mrm.20683
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We developed a live high-field multiple-mouse magnetic resonance imaging method to increase the throughput of imaging studies involving large numbers of mice. Phantom experiments were performed in 7 shielded radiofrequency (RF) coils for concurrent imaging on a 7 Tesla MRI scanner outfitted with multiple transmit and receive channels to confirm uniform signal-to-noise ratio and minimal ghost artifacts across images from the different RF coils. Grid phantoms were used to measure image distortion in different positions in the coils. The brains of 7 live mice were imaged in 3D in the RF coil array, and a second array of 16 RF coils was used to 313 image the whole bodies of 16 fixed, contrast agent-perfused mice. The images of the 7 live mouse brains at 156 mu m isotropic resolution and the 16 whole fixed mice at 100 mu m isotropic resolution were of high quality and free of artifacts. We have thus shown that multiple-mouse MRI increases throughput for live and fixed mouse experiments by a factor equaling the number of RF coils in the scanner.
引用
收藏
页码:1311 / 1316
页数:6
相关论文
共 50 条
  • [1] Multiple-mouse MRI
    Bock, NA
    Konyer, NB
    Henkelman, RM
    MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (01) : 158 - 167
  • [2] Multiple-Mouse MRI with Multiple Arrays of Receive Coils
    Ramirez, Marc S.
    Esparza-Coss, Emilio
    Bankson, James A.
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (03) : 803 - 810
  • [3] A throughput-optimized array system for multiple-mouse MRI
    Ramirez, Marc S.
    Lai, Stephen Y.
    Bankson, James A.
    NMR IN BIOMEDICINE, 2013, 26 (03) : 237 - 247
  • [4] Feasibility of multiple-mouse dynamic contrast-enhanced MRI
    Ramirez, Marc S.
    Ragan, Dustin K.
    Kundra, Vikas
    Banksonl, James A.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (03) : 610 - 615
  • [5] Multiple-mouse Neuroanatomical Magnetic Resonance Imaging
    Dazai, Jun
    Spring, Shoshana
    Cahill, Lindsay S.
    Henkelman, R. Mark
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2011, (48):
  • [6] Multiple-mouse magnetic resonance imaging with cryogenic radiofrequency probes for evaluation of brain development
    Arbabi, A.
    Noakes, L. Spencer
    Vousden, D.
    Dazai, J.
    Spring, S.
    Botelho, O.
    Keshavarzian, T.
    Mattingly, M.
    Ellegood, J. E.
    Nutter, L. M. J.
    Wissmann, R.
    Sled, J. G.
    Lerch, J. P.
    Henkelman, R. M.
    Nieman, B. J.
    NEUROIMAGE, 2022, 252
  • [7] MRI of the Carotid Artery at 7 Tesla: Quantitative Comparison With 3 Tesla
    Koning, Wouter
    de Rotte, Alexandra A. J.
    Bluemink, Johanna J.
    van der Velden, Tijl A.
    Luijten, Peter R.
    Klomp, Dennis W. J.
    Zwanenburg, Jaco J. M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (03) : 773 - 780
  • [8] Mesoscopic in vivo human T*2 dataset acquired using quantitative MRI at 7 Tesla
    Gulban, Omer Faruk
    Bollmann, Saskia
    Huber, Laurentius
    Wagstyl, Konrad
    Goebel, Rainer
    Poser, Benedikt A.
    Kay, Kendrick
    Ivanov, Dimo
    NEUROIMAGE, 2022, 264
  • [9] Subjective acceptance of 7 Tesla MRI for human imaging
    Jens M. Theysohn
    Stefan Maderwald
    Oliver Kraff
    Christoph Moenninghoff
    Mark E. Ladd
    Susanne C. Ladd
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2008, 21
  • [10] Subjective acceptance of 7 Tesla MRI for human imaging
    Theysohn, Jens M.
    Maderwald, Stefan
    Kraff, Oliver
    Moenninghoff, Christoph
    Ladd, Mark E.
    Ladd, Susanne C.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2008, 21 (1-2) : 63 - 72