Selective voltammetric determination of norepinephrine in the presence of acetaminophen and folic acid at a modified carbon nanotube paste electrode

被引:143
作者
Beitollahi, Hadi [1 ]
Sheikhshoaie, Iran [2 ]
机构
[1] Int Ctr Sci High Technol & Environm Sci, Dept Environm, Res Inst Environm Sci, Kerman, Iran
[2] Shahid Bahonar Univ Kerman, Dept Chem, Fac Sci, Kerman, Iran
关键词
Norepinephrine; Acetaminophen; Folic acid; Carbon nanotubes; Modified electrode; Electrocatalysis; URIC-ACID; ELECTROCHEMICAL SENSOR; ELECTROCATALYTIC DETERMINATION; ASCORBIC-ACID; EPINEPHRINE; OXIDATION; DOPAMINE; CATECHOLAMINES; PERFORMANCE; CHROMATOGRAPHY;
D O I
10.1016/j.jelechem.2011.08.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A carbon paste electrode (CPE) was modified by incorporation of carbon nanotubes and a molybdenum (VI) complex (MC) and studied in pH 7.0 phosphate buffer solution (PBS) by cyclic voltammetry (CV). The apparent charge transfer rate constant, k(s), and transfer coefficient, alpha, for electron transfer between MC and CNT paste electrode were calculated. The modified electrode showed an excellent electrocatalytic effect on the oxidation of norepinephrine (NE). In PBS of pH 7.0, the oxidation current increased linearly with two concentration intervals of NE, one is 0.08-30.0 mu M and, the other is 30.0-700.0 mu M. The detection limit (3 sigma) obtained by differential pulse voltammetry (DPV) was 43.0 nM. Then the modified electrode was used to determine NE in an excess of acetaminophen (AC) and folic acid (FA) by DPV. The peak potentials recorded in a PBS of pH 7.0 were 220, 480 and 800 mV vs. Ag/AgCl/KCl (3.0 M) for NE, AC and FA, respectively. Finally, this method was used for the determination of NE in NE ampoule and urine samples. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:336 / 342
页数:7
相关论文
共 52 条
[41]   Folic acid: neurochemistry, metabolism and relationship to depression [J].
Paul, RTP ;
McDonnell, AP ;
Kelly, CB .
HUMAN PSYCHOPHARMACOLOGY-CLINICAL AND EXPERIMENTAL, 2004, 19 (07) :477-488
[42]   Simultaneous liquid chromatographic analysis of catecholamines and 4-hydroxy-3-methoxyphenylethylene glycol in human plasma - Comparison of amperometric and coulometric detection [J].
Sabbioni, C ;
Saracino, MA ;
Mandrioli, R ;
Pinzauti, S ;
Furlanetto, S ;
Gerra, G ;
Raggi, MA .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1032 (1-2) :65-71
[43]   Electrochemical evidences in oxidation of acetaminophen in the presence of glutathione and N-acetylcysteine [J].
Shayani-Jam, Hasan ;
Nematollahi, Davood .
CHEMICAL COMMUNICATIONS, 2010, 46 (03) :409-411
[44]   A novel tridentate Schiff base dioxo-molybdenum(VI) complex: Synthesis, crystal structure and catalytic performance in green oxidation of sulfides by urea hydrogen peroxide [J].
Sheikhsoaie, Iran ;
Rezaeffard, Abdolreza ;
Monadi, Niaz ;
Kaafi, Samira .
POLYHEDRON, 2009, 28 (04) :733-738
[45]   Amperometric immunosensor for ricin by using on graphite and carbon nanotube paste electrodes [J].
Suresh, S. ;
Gupta, A. K. ;
Rao, V. K. ;
Kumar, Om ;
Vijayaraghavan, R. .
TALANTA, 2010, 81 (1-2) :703-708
[46]  
Taheri AR, 2011, INT J ELECTROCHEM SC, V6, P171
[47]  
Voet D., 1995, Biochemistry
[48]   Electrochemical waste water treatment: Electrooxidation of acetaminophen [J].
Waterston, K ;
Wang, JWJ ;
Bejan, D ;
Bunce, NJ .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 2006, 36 (02) :227-232
[49]  
Yaghoubian H, 2010, INT J ELECTROCHEM SC, V5, P1411
[50]   Calix[4]arene crown-4 ether modified glassy carbon electrode for electrochemical determination of norepinephrine [J].
Zhang, Hai-Li ;
Liu, Ya ;
Lai, Guo-Song ;
Yu, Ai-Min ;
Huang, Yu-Mei ;
Jin, Chuan-Ming .
ANALYST, 2009, 134 (10) :2141-2146