Impacts of Non-Sinusoidal Load Currents on Distribution Transformer Losses-Part II: Standard Aspects and Experimental Measurement

被引:0
作者
Mirzaie, M. [1 ]
Yazdani-Asrami, M.
Sadati, S. B. [3 ]
Akmal, A. Shayegani [2 ]
机构
[1] Babol Univ Technol, Dept Elect & Comp Engn, Babol Sar, Iran
[2] Islamic Azad Univ, Sari Branch, SAMA Tech & Vocat Training Coll, Sari, Iran
[3] Univ Tehran, Fac Engn, Dept Elect & Comp Engn, Tehran, Iran
来源
INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE | 2011年 / 6卷 / 05期
关键词
Compact Fluorescent Lamps; Derating; Distribution Transformers; Experimental Measurement; Harmonics; Losses; Non-Linear Loads; AMBIENT-TEMPERATURE; POWER;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Nowadays, reliability is an inevitable part of power system studies and operation, due to significant increase in the number of industrial electrical consumers. Transformer is one of the major and critical components in power system and distribution network in the area of reliability issue, since their outage may result in costly and time-consuming repair or replacement. Nowadays, loads of transformers are widely perturbed with harmonics. Harmonic components cause the transformer losses to increase and thus, transformer may fail to operate. In this paper, as a Part II of our study, effects of non-sinusoidal load currents on distribution transformer losses have been studied by means of IEEE standard and experimental measurement. For this purpose, the losses of a typical distribution transformer under non-sinusoidal loads have been measured. Afterwards, by considering harmonic spectrum of the used non-linear loads, transformer losses have been calculated using IEEE C 57.110 standard. Finally, obtained results have been compared. It should be mentioned that in Part I of this study, distribution transformer losses under non-sinusoidal load currents have been evaluated and calculated using Finite Element Method and a circuit based method by means of a transient software. Copyright (C) 2011 Praise Worthy Prize S.r.l. - All rights reserved.
引用
收藏
页码:2215 / 2220
页数:6
相关论文
共 19 条
[1]  
ANDRIUSIENE L, 2003, ELECT ELECT ENG J KA, V44, P43
[2]   Measurements and correction of no-load losses of power transformers [J].
Arseneau, R ;
So, E ;
Hanique, E .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2005, 54 (02) :503-506
[3]  
*CHAUV ARN GROUP, C A8310 US MAN TEST
[4]   A New Technique for Modeling Hysteresis Phenomenon in Soft Magnetic Materials [J].
Faiz, Jawad ;
Saffari, S. .
ELECTROMAGNETICS, 2010, 30 (04) :376-401
[5]   Mixed Derating of Distribution Transformers Under Unbalanced Supply Voltage and Nonlinear Load Conditions Using TSFEM [J].
Faiz, Jawad ;
Ebrahimi, Bashir Mahdi ;
Ghofrani, Mahmoud .
IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (02) :780-789
[6]  
*IEEE, 1995, C571291 IEEE
[7]  
*IEEE, 2000, C57110 IEEE
[8]  
Kostic MM, 2010, INT REV ELECTR ENG-I, V5, P447
[9]   Power system even harmonics and power quality indices [J].
Liu, Y ;
Heydt, GT .
ELECTRIC POWER COMPONENTS AND SYSTEMS, 2005, 33 (08) :833-844
[10]  
MAKAROV SN, 2000, P 9 INT C HARM POW Q, V1, P87