3D displacement of the middle ear ossicles in the quasi-static pressure regime using new X-ray stereoscopy technique

被引:5
作者
Salih, Wasil H. M. [1 ,2 ]
Soons, Joris A. M. [2 ]
Dirckx, Joris J. J. [2 ]
机构
[1] Alneelain Univ, Dept Biomed Phys, Algamhouria Ave, Khartoum, Sudan
[2] Univ Antwerp, Lab Biomed Phys, Groenenborgerlaan 171, B-2020 Antwerp, Belgium
关键词
Ossicular chain motion; X-ray stereoscopy; Transfer function; GERBIL TYMPANIC MEMBRANE; EARDRUM; DEFORMATION; VIBRATION; RABBIT; CAT;
D O I
10.1016/j.heares.2015.12.003
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
A novel X-ray stereoscopy technique, using greyscale information obtained from moving markers, was used to study the 3D motion in both gerbil and rabbit middle ear ossicles in the quasi-static pressure regime. The motion can be measured without visually exposing the ossicles. The ossicles showed non-linear behaviour as a function of both pressure and frequency. For instance, about 80% of the maximum umbo displacement occurs at a 1 kPa (peak-to-peak) pressure load, while a limited increase of the amplitude is noticed when the pressure goes to 2 kPa. In rabbit the ratio of stapes to umbo motion amplitude was 0.35 for a pressure of 2 kPa (peak-to-peak) at 0.5 Hz. From two stereoscopic projections of the marker paths, 3D motion of the ossicles could be calculated. This motion is demonstrated on high resolution computer models in order to visualize ossicular chain behaviour. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:60 / 68
页数:9
相关论文
共 27 条
[1]   Viscoelastic properties of gerbil tympanic membrane at very low frequencies [J].
Aernouts, Jef ;
Dirckx, Joris J. J. .
JOURNAL OF BIOMECHANICS, 2012, 45 (06) :919-924
[2]   Elastic characterization of the gerbil pars flaccida from in situ inflation experiments [J].
Aernouts, Jef ;
Dirckx, Joris J. J. .
BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2011, 10 (05) :727-741
[3]   MODELING THE MALLEUS VIBRATION AS A RIGID-BODY MOTION WITH ONE ROTATIONAL AND ONE TRANSLATIONAL DEGREE-OF-FREEDOM [J].
DECRAEMER, WF ;
KHANNA, SM .
HEARING RESEARCH, 1994, 72 (1-2) :1-18
[4]   HUMAN TYMPANIC MEMBRANE DEFORMATION UNDER STATIC PRESSURE [J].
DIRCKX, JJJ ;
DECRAEMER, WF .
HEARING RESEARCH, 1991, 51 (01) :93-106
[5]   Effect of middle ear components on eardrum quasi-static deformation [J].
Dirckx, JJJ ;
Decraemer, WF .
HEARING RESEARCH, 2001, 157 (1-2) :124-137
[6]   Measurement and modeling of boundary shape and surface deformation of the Mongolian gerbil pars flaccida [J].
Dirckx, JJJ ;
Decraemer, WF ;
vonUnge, M ;
Larsson, C .
HEARING RESEARCH, 1997, 111 (1-2) :153-164
[7]   Quasi-static transfer function of the rabbit middle ear, measured with a heterodyne interferometer with high-resolution position decoder [J].
Dirckx, Joris J. J. ;
Buytaert, Jan A. N. ;
Decraemer, Willem F. .
JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2006, 7 (04) :339-351
[8]   Linear and quasi-linear viscoelastic characterization of ankle ligaments [J].
Funk, JR ;
Hall, GW ;
Crandall, JR ;
Pilkey, WD .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2000, 122 (01) :15-22
[9]   Tympanometric preconditioning of the tympanic membrane [J].
Gaihede, M .
HEARING RESEARCH, 1996, 102 (1-2) :28-34
[10]   Human middle ear transfer function measured by double laser interferometry system [J].
Gan, TZ ;
Wood, TW ;
Dormer, TJ .
OTOLOGY & NEUROTOLOGY, 2004, 25 (04) :423-435