An apparent threshold dose response in ferrous xylenol-orange gel dosimeters when scanned with a yellow light source

被引:44
作者
Babic, Steven [1 ,2 ]
Battista, Jerry [1 ,2 ]
Jordan, Kevin [1 ,2 ]
机构
[1] London Hlth Sci Ctr, London Reg Canc Program, Dept Phys & Engn, London, ON N6A 4L6, Canada
[2] Univ Western Ontario, Dept Med Biophys, London, ON N6A 5C1, Canada
关键词
D O I
10.1088/0031-9155/53/6/009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Freshly prepared radiochromic ferrous xylenol-orange ( FX) gels optically scanned with a light source exhibit a threshold dose response that is thermally and wavelength dependent. Correction for this threshold dose leads to accurate dose calibration and better reproducibility in multiple fraction radiation exposures. The objective of this study was to determine the cause of the threshold dose effect and to control it through improved dose calibration procedures. The results of a systematic investigation into the chemical cause revealed that impurities within the various FX gel constituents ( i.e. xylenol-orange, gelatin, sulfuric acid and ferrous ammonium sulfate) were not directly responsible for the threshold dose. Rather, it was determined that the threshold dose response stems from a spectral sensitivity to different chemical complexes that are formed at different dose levels in FX gels between ferric ( Fe( III)) ions and xylenol-orange ( XO), i. e. Fe( III)(i):XO(j). A double Fe( III)(2):XO(1) complex preferentially absorbs at longer wavelengths ( i. e. yellow), while at shorter wavelengths ( i. e. green) the sensitivity is biased toward the single Fe( III)(1):XO(1) complex. As a result, when scanning with yellow light, freshly prepared FX gels require a minimum concentration of Fe( III) ions to shift the equilibrium concentration to favor the predominant production of the double Fe( III)(2):XO(1) complex at low doses. This can be accomplished via pre-irradiation of freshly prepared gels to a priming dose of similar to 0.5 Gy or allowing auto-oxidation to generate the startup concentration of Fe( III) ions required to negate the apparent threshold dose response.
引用
收藏
页码:1637 / 1650
页数:14
相关论文
共 37 条
[1]  
[Anonymous], ANAL SCI
[2]  
ATTIX F. H., 1986, Introduction to radiological physics and radiation dosimetry
[3]   Dosimetric properties of a radiochromic gel detector for diagnostic X-rays [J].
Bero, M. A. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01) :186-189
[4]   Radiochromic gel dosemeter for three-dimensional dosimetry [J].
Bero, MA ;
Gilboy, WB ;
Glover, PM .
RADIATION PHYSICS AND CHEMISTRY, 2001, 61 (3-6) :433-435
[5]   Tissue-equivalent gel for non-invasive spatial radiation dose measurements [J].
Bero, MA ;
Gilboy, WB ;
Glover, PM ;
El-masri, HM .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2000, 166 :820-825
[6]   PRACTICAL ASPECTS OF FERROUS SULPHATE DOSIMETRY [J].
DAVIES, JV ;
LAW, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1963, 8 (1-4) :91-&
[7]   Three-dimensional dosimetry using polymer gel and magnetic resonance imaging applied to the verification of conformal radiation therapy in head-and-neck cancer [J].
De Deene, Y ;
De Wagter, C ;
Van Duyse, B ;
Derycke, S ;
De Neve, W ;
Achten, E .
RADIOTHERAPY AND ONCOLOGY, 1998, 48 (03) :283-291
[8]   A CCD-based optical CT scanner for high-resolution 3D imaging of radiation dose distributions: equipment specifications, optical simulations and preliminary results [J].
Doran, SJ ;
Koerkamp, KK ;
Bero, MA ;
Jenneson, P ;
Morton, EJ ;
Gilboy, WB .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (12) :3191-3213
[9]  
Fricke H., 1966, CHEM DOSIMETRY RAD D, V2
[10]   Determination of iron in solutions with the ferric-xylenol orange complex [J].
Gay, C ;
Collins, J ;
Gebicki, JM .
ANALYTICAL BIOCHEMISTRY, 1999, 273 (02) :143-148