Determination of two HMG-CoA reductase inhibitors, pravastatin and pitavastatin, in plasma samples using liquid chromatography-tandem mass spectrometry for pharmaceutical study

被引:27
作者
Deng, Jian-Wei [1 ,2 ]
Kim, Kwon-Bok [1 ,2 ]
Song, Im-Sook [1 ,2 ]
Shon, Ji-Hong [1 ,2 ,3 ,4 ]
Zhou, Hong-Hao [5 ]
Liu, Kwang-Hyeon [1 ,2 ]
Shin, Jae-Gook [1 ,2 ,3 ,4 ]
机构
[1] Inje Univ, Coll Med, Dept Pharmacol, Pusan 614735, South Korea
[2] Inje Univ, Coll Med, PharmacoGenom Res Ctr, Pusan 614735, South Korea
[3] Inje Univ, Busan Paik Hosp, Dept Clin Pharmacol, Pusan, South Korea
[4] Inje Univ, Busan Paik Hosp, Clin Trial Ctr, Pusan, South Korea
[5] Cent S Univ, Pharmacogenet Res Inst, Inst Clin Pharmacol, Changsha 410078, Hunan, Peoples R China
关键词
pravastatin; pitavastatin; HMG-CoA; LC-MS/MS;
D O I
10.1002/bmc.905
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We developed a method for determining pravastatin or pitavastatin, 3-hydroxy-3-methylglutaryl coenzyme A (HMG-CoA) reductase inhibitors, in plasma using liquid chromatography and tandem mass spectrometry (LC-MS/MS). Pravastatin, pitavastatin and the internal standard fluvastatin were extracted from plasma with solid-phase extraction columns and eluted with methanol. After drying the organic layer, the residue was reconstituted in mobile phase (acetonitrile:water, 90:10, v/v) and injected onto a reversed-phase C-18 column. The isocratic mobile phase was eluted at 0.2 mL/min. The ion transitions recorded in multiple reaction monitoring mode were m/z 423 -> 101, 420 -> 290 and 410 -> 348 for pravastatin, pitavastatin and fluvastatin, respectively. The coefficient of variation of the assay precision was less than 12.4%, the accuracy exceeded 89%. The limit of detection was 1 ng/mL for all analytes. This method was used to measure the plasma concentration of pitavastatin or pravastatin from healthy subjects after a single 4 mg oral dose of pitavastatin or 40 mg oral dose of pravastatin. This is a very simple, sensitive and accurate analytic method to determine the pharmacokinetic profiles of pitavastatin or pravastatiny. Copyright (c) 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:131 / 135
页数:5
相关论文
共 23 条
[1]   Quantification of pravastatin in human plasma and urine after solid phase extraction using high performance liquid chromatography with ultraviolet detection [J].
Bauer, S ;
Mwinyi, J ;
Stoeckle, A ;
Gerloff, T ;
Roots, I .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 818 (02) :257-262
[2]   Effect of OATPIBI (SLCOIBI) variant alleles on the pharmacokinetics of pitavastatin in healthy volunteers [J].
Chung, JY ;
Cho, JY ;
Yu, KS ;
Kim, JR ;
Oh, DS ;
Jung, HR ;
Lim, KS ;
Moon, KH ;
Shin, SG ;
Jang, IJ .
CLINICAL PHARMACOLOGY & THERAPEUTICS, 2005, 78 (04) :342-350
[3]  
Fujino Hideki, 2004, Drug Metabol Drug Interact, V20, P25
[4]   Clinical pharmacokinetics of pravastatin - Mechanisms of pharmacokinetic events [J].
Hatanaka, T .
CLINICAL PHARMACOKINETICS, 2000, 39 (06) :397-412
[5]   Drug-drug interaction between pitavastatin and various drugs via OATP1B1 [J].
Hirano, Masaru ;
Maeda, Kazuya ;
Shitara, Yoshihisa ;
Sugiyama, Yuichi .
DRUG METABOLISM AND DISPOSITION, 2006, 34 (07) :1229-1236
[6]   Quantitative determination of pravastatin and R-416, its main metabolite in human plasma, by liquid chromatography-tandem mass spectrometry [J].
Kawabata, K ;
Samata, N ;
Urasaki, Y .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 816 (1-2) :73-79
[7]   Simultaneous determination of NK-104 and its lactone in biological samples by column-switching high-performance liquid chromatography with ultraviolet detection [J].
Kojima, A ;
Fujino, H ;
Yosimura, M ;
Morikawa, H ;
Kimata, H .
JOURNAL OF CHROMATOGRAPHY B, 1999, 724 (01) :173-180
[8]   Clinical pharmacokinetics of atorvastatin [J].
Lennernäs, H .
CLINICAL PHARMACOKINETICS, 2003, 42 (13) :1141-1160
[9]   Effects of organic anion transporting polypeptide IBI haplotype on pharmacokinetics of pravastatin, valsartan, and temocapril [J].
Maeda, Kazuya ;
Ieiri, Ichiro ;
Yasuda, Kuninobu ;
Fujino, Akiharu ;
Fujiwara, Hiroaki ;
Otsubo, Kenji ;
Hirano, Masaru ;
Watanabe, Takao ;
Kitamura, Yoshiaki ;
Kusuhara, Hiroyuki ;
Sugiyama, Yuichi .
CLINICAL PHARMACOLOGY & THERAPEUTICS, 2006, 79 (05) :427-439
[10]   Determination of cholesterol-lowering statin drugs in aqueous samples using liquid chromatography-electrospray ionization tandem mass spectrometry [J].
Miao, XS ;
Metcalfe, CD .
JOURNAL OF CHROMATOGRAPHY A, 2003, 998 (1-2) :133-141