Is ministernotomy superior to right anterior minithoracotomy in minimally invasive aortic valve replacement?

被引:24
作者
Balmforth, Damian [1 ]
Harky, Amer [1 ]
Lall, Kulvinder [1 ]
Uppal, Rakesh [1 ]
机构
[1] St Bartholomews Hosp, Barts Heart Ctr, Dept Cardiothorac Surg, London, England
关键词
Aortic valve replacement; Ministernotomy; Minithoracotomy;
D O I
10.1093/icvts/ivx241
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A best evidence topic was constructed according to a structured protocol. The question addressed was whether, in patients undergoing minimally invasive aortic valve replacement (AVR), right anterior thoracotomy (RT) or mini-sternotomy (MS) was superior in terms of postoperative outcome? A total of 840 publications were found using the reported search. Of these, 6 represented the best available evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. In all, except 1 study, the primary outcome was early mortality, ranging from in-hospital mortality to 90 days postoperatively. The remaining study was a cost-benefit analysis. Four studies were non-randomized observational studies, one of which was multicentre. Two were meta-analyses of studies comparing minithoracotomy or MS with conventional sternotomy for AVR, rather than direct comparisons of the 2 minimal access techniques. We conclude that there is a lack of high-quality evidence comparing RT and MS for minimally invasive AVR, with no randomized controlled trials to date. The available evidence shows no difference in early mortality between RT and MS for surgical AVR. In studies that directly compared RT and MS, RT was found to be associated with reduced length of hospital stay, despite longer cardiopulmonary bypass times and cross-clamp times. One study reported groin complications (10.8%) with the RT group, where peripheral cannulation was used, while the other 5 studies did not comment on groin complications associated with peripheral cannulation. In the only cost-benefit analysis, RT was found to carry considerably more cost than MS over and above conventional AVR.
引用
收藏
页码:818 / 821
页数:4
相关论文
共 50 条
  • [21] Minimally Invasive Aortic Valve Replacement
    Salenger, Rawn
    Gammie, James S.
    Collins, Julia A.
    JOURNAL OF CARDIAC SURGERY, 2016, 31 (01) : 38 - 50
  • [22] Right anterior minithoracotomy versus conventional aortic valve replacement: A propensity score matched study
    Glauber, Mattia
    Miceli, Antonio
    Gilmanov, Daniyar
    Ferrarini, Matteo
    Bevilacqua, Stefano
    Farneti, Pier A.
    Solinas, Marco
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 145 (05) : 1222 - 1226
  • [23] Consensus statement on aortic valve replacement via an anterior right minithoracotomy in the UK healthcare setting
    Vohra, Hunaid A.
    Salmasi, M. Yousuf
    Mohamed, Fatemazahra
    Shehata, Monica
    Bahrami, Bardia
    Caputo, Massimo
    Deshpande, Ranjit
    Bapat, Vinayak
    Bahrami, Toufan
    Birdi, Inderpaul
    Zacharias, Joseph
    OPEN HEART, 2023, 10 (01):
  • [24] Right Anterior versus Right Transaxillary Access for Minimally Invasive Aortic Valve Replacement: A Propensity Matched Competitive Analysis
    Taghizadeh-Waghefi, Ali
    Arzt, Sebastian
    Wenzel, Lisa
    Petrov, Asen
    Wilbring, Manuel
    Matschke, Klaus
    Kappert, Utz
    Alexiou, Konstantin
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (04)
  • [25] Rapid deployment valve system shortens operative times for aortic valve replacement through right anterior minithoracotomy
    Constanze Bening
    Khaled Hamouda
    Mehmet Oezkur
    Christoph Schimmer
    Ina Schade
    Armin Gorski
    Ivan Aleksic
    Rainer Leyh
    Journal of Cardiothoracic Surgery, 12
  • [26] Outcomes of minimally invasive aortic valve replacement surgery
    Young, Christopher P.
    Sinha, Shubhra
    Vohra, Hunaid A.
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 53 : 19 - 23
  • [27] A comparison of minimally invasive and standard aortic valve replacement
    Stolinski, Jarosaw
    Plicner, Dariusz
    Grudzien, Grzegorz
    Wasowicz, Marcin
    Musial, Robert
    Andres, Janusz
    Kapelak, Bogusaw
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2016, 152 (04) : 1030 - 1039
  • [28] Minimally invasive aortic valve replacement with a sutureless valve through a right anterior mini-thoracotomy versus transcatheter aortic valve implantation in high-risk patients
    Miceli, Antonio
    Gilmanov, Daniyar
    Murzi, Michele
    Marchi, Federica
    Ferrarini, Matteo
    Cerillo, Alfredo G.
    Quaini, Eugenio
    Solinas, Marco
    Berti, Sergio
    Glauber, Mattia
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2016, 49 (03) : 960 - 965
  • [29] Concurrent Minimally Invasive Aortic Valve Replacement and Coronary Artery Bypass via Limited Right Anterior Thoracotomy
    Lewis, Clifton T. P.
    Stephens, Richard L.
    Cline, Jennifer L.
    Tyndal, Charles M.
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2015, 10 (04) : 273 - 275
  • [30] Minimally invasive surgical aortic valve replacement
    Jahangiri, Marjan
    Hussain, Azhar
    Akowuah, Enoch
    HEART, 2019, 105 : S10 - S15