3D simulation of aneurysm clipping: Data analysis

被引:1
|
作者
Mery, Francisco [1 ]
Mendez-Orellana, Carolina [1 ,2 ]
Torres, Javier [3 ]
Aranda, Francisco [1 ]
Caro, Ivan [4 ]
Pesenti, Jose [5 ]
Rojas, Ricardo [1 ]
Villanueva, Pablo [1 ]
Germano, Isabelle [6 ]
机构
[1] Pontificia Univ Catolica Chile, Sch Med, Dept Neurosurg, Marcoleta 347, Santiago, Chile
[2] Pontificia Univ Catolica Chile, Fac Med, Sch Speech & Language Pathol, Santiago, Chile
[3] Pontificia Univ Catolica Valparaiso, Sch Psychol, Sch Philosophy & Educ, Valparaiso, Chile
[4] Pontificia Univ Catolica Chile, Sch Design, Sch Architecture, Santiago, Chile
[5] Pontificia Univ Catolica Chile, Sch Med, Sci, Santiago, Chile
[6] Icahn Sch Med Mt Sinai, Dept Neurosurg, New York, NY 10029 USA
来源
DATA IN BRIEF | 2021年 / 37卷
关键词
Neurosurgery education; Aneurysm clipping; Training model; 3D printing; Simulation; Data analysis;
D O I
10.1016/j.dib.2021.107258
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Aneurysm clipping requires the proficiency of several skills, yet the traditional way of practicing them has been recently challenged. The use of simulators could be an alternative educational tool. The aim of this data analysis is to provide further evaluation of a reusable low-cost 3D printed training model we developed for aneurysm clipping [1]. The simulator was designed to replicate the bone structure, arteries and targeted aneurysms. Thirty-two neurosurgery residents performed a craniotomy and aneurysm clipping using the model and then filled out a survey. The survey was designed in two parts: a 5-point Likert scale questionnaire and three questions requiring written responses [1]. Two dimensions of the model were evaluated by the questionnaire: the face validity, assessed by 5 questions about the realism of the model, and the content validity, assessed by 6 questions regarding the usefulness of the model during the different steps of the training procedure. The three questions requiring written responses referred to the strengths and weaknesses of the simulator and a global yes/no question as to whether or not they would repeat the experience. Demographic data, experience level and survey responses of the residents were grouped in a dataset [2]. A descriptive analysis was performed for each dimension. Then, the groups were compared according to their level of expertise Uunior and Senior groups) with an indepen-dent sample t-test. A Confirmatory Factor Analysis (CFA) was estimated, using a Weighted Least Squares Mean Variance adjusted (WLSMV) which works best for the ordinal data [3]. Fitness was calculated using chi-square (chi(2)) test, Comparative Fit Index (CFI), Tucker-Lewis Index (TLI), and the Root Mean Square Error of Approximation (RMSEA). A non-significant chi(2), CFI and TLI greater than 0.90 and RMSEA < 0.08 were considered an acceptable fit [4]. All data analysis was performed using IBM SPSS 23.0 statistical software. Data are reported as mean + standard deviation (SD). A probability p < 0.05 was considered significant. Exploratory Factor Analysis was done to explore the factorial structure of the 11-items scale in the sample, first we performed a principal components analysis. The Kaiser-Meyer-Olkin measure verified the sampling adequacy for the analysis (KMO = 0.784; Bartlett's Test of Sphericity chi(2) (55) = 243.44, p < .001), indicating correlation is adequate for factor analysis. Considering Eigen values greater than 1, a two-factor solution explained 73.1% of the variance but left one item in factor 2 (Q 11). The results of this factor analysis are presented in Table 1. Confirmatory Factor Analysis, considering only the 10 items in the first factor (removing question 11 of our model), was performed. This model reached the following fit: chi(2) (35) = 38.821, p > .05; CFI = 0.997; TLI = 0.996; RMSEA 0.058, without any error terms to exhibit covariance. Regarding the reliability of the questionnaire, the internal consistency was explored in the 10 items selected in the confirmatory factor analysis with an alpha coefficient (alpha = 0.941). (C) 2021 The Authors. Published by Elsevier Inc.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Reusable Low-Cost 3D Training Model for Aneurysm Clipping
    Mery, Francisco
    Aranda, Francisco
    Mendez-Orellana, Carolina
    Caro, Ivan
    Pesenti, Jose
    Torres, Javier
    Rojas, Ricardo
    Villanueva, Pablo
    Germano, Isabelle
    WORLD NEUROSURGERY, 2021, 147 : 29 - 36
  • [2] Cerebral Aneurysm Clipping Surgery Simulation Using Patient-Specific 3D Printing and Silicone Casting
    Ryan, Justin R.
    Almefty, Kaith K.
    Nakaji, Peter
    Frakes, David H.
    WORLD NEUROSURGERY, 2016, 88 : 175 - 181
  • [3] 3D printing for aneurysms clipping elective surgery
    Guarino, S.
    Marchese, E.
    Ponticelli, G. S.
    Scerrati, A.
    Tagliaferri, V
    Trovalusci, F.
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2022, 39 (04) : 412 - 425
  • [4] Re-using 3D modeling data for constructing 3D simulation data
    Kwak, Jonggeun
    Ko, Min. S.
    Park, Sang C.
    Wang, Gi-Nam
    ICINCO 2008: PROCEEDINGS OF THE FIFTH INTERNATIONAL CONFERENCE ON INFORMATICS IN CONTROL, AUTOMATION AND ROBOTICS, VOL RA-2: ROBOTICS AND AUTOMATION, VOL 2, 2008, : 94 - +
  • [5] Metamaterial design for aortic aneurysm simulation using 3D printing
    Sakai, Arthur K. F.
    Cestari, Ismar N.
    de Sales, Eraldo
    Mazzetto, Marcelo
    Cestari, Idagene A.
    3D PRINTING IN MEDICINE, 2024, 10 (01)
  • [6] 3D Analysis of Diferent Metamaterial Geometry and Simulation of Metamaterial Usage
    Kosic, Boris
    Stojicevic, Misa
    Jeli, Zorana
    Pokonstantinovic, Branislav
    Duta, Alina
    Dragicevic, Aleksandra
    FME TRANSACTIONS, 2019, 47 (02): : 349 - 354
  • [7] Simulation of Endovascular Aortic Repair Using 3D Printed Abdominal Aortic Aneurysm Model and Fluid Pump
    Jussi M. Kärkkäinen
    Giuliano Sandri
    Emanuel R. Tenorio
    Amy Alexander
    Karen Bjellum
    Jane Matsumoto
    Jonathan Morris
    Bernardo C. Mendes
    Randall R. DeMartino
    Gustavo S. Oderich
    CardioVascular and Interventional Radiology, 2019, 42 : 1627 - 1634
  • [8] Simulation of Endovascular Aortic Repair Using 3D Printed Abdominal Aortic Aneurysm Model and Fluid Pump
    Karkkainen, Jussi M.
    Sandri, Giuliano
    Tenorio, Emanuel R.
    Alexander, Amy
    Bjellum, Karen
    Matsumoto, Jane
    Morris, Jonathan
    Mendes, Bernardo C.
    DeMartino, Randall R.
    Oderich, Gustavo S.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2019, 42 (11) : 1627 - 1634
  • [9] SIMULATION OF FACADE REFERENCE DATA FOR 3D SAR ALGORITHMS
    Auer, Stefan
    Gernhardt, Stefan
    Eder, Konrad
    Gisinger, Christoph
    2015 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2015, : 2927 - 2930
  • [10] Training in Cerebral Aneurysm Clipping Using Self-Made 3-Dimensional Models
    Mashiko, Toshihiro
    Kaneko, Naoki
    Konno, Takehiko
    Otani, Keisuke
    Nagayama, Rie
    Watanabe, Eiju
    JOURNAL OF SURGICAL EDUCATION, 2017, 74 (04) : 681 - 689