Indications for exchange or explantation of phakic implantable collamer lens with central port in patients with and without keratoconus

被引:3
作者
Alhamzah, Albanderi [1 ]
Alharbi, Saad S. [2 ]
Alfardan, Fahad [3 ,4 ]
Aldebasi, Tariq [3 ]
Almudhaiyan, Tariq [3 ,4 ]
机构
[1] King Saud bin Abdulaziz Univ Hlth Sci, Coll Med, Riyadh 22490, Saudi Arabia
[2] King Khalid Eye Specialist Hosp, Anerior Segment Dept, Riyadh 7191, Saudi Arabia
[3] Natl Guard Hosp, Dept Surg, Div Ophthalmol, Riyadh 22490, Saudi Arabia
[4] King Abdullah Int Med Res Ctr, Riyadh 22490, Saudi Arabia
关键词
explantation; exchange; implantable collamer lens; vault; TORIC ICL IMPLANTATION; WHITE-TO-WHITE; INTRAOCULAR LENSES; ANTERIOR SEGMENT; CROSS-LINKING; CONTACT-LENS; CENTRAL HOLE; FOLLOW-UP; SAFETY; MODERATE;
D O I
10.18240/ijo.2021.11.10
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
AIM: To evaluate the causes of phakic implantable collamer lens (ICL) exchange/explantation in patients with and without keratoconus (KC) at two tertiary hospitals in Riyadh, Saudi Arabia. METHODS: A retrospective chart review of all patients who underwent ICL (model V4c with central port) exchange/ explantation was performed using the electronic medical record systems. All available preoperative and postoperative data were documented for each patient. RESULTS: Over 7y, 2283 ICL implantation procedures were performed; 46 implants (2%) required exchange (21 implants)/explantation (25 implants), of which 14 cases (30.4%) were patients with KC. Indications for ICL exchange/explantation in non-KC group were vault measurement, cataract formation, increased intraocular pressure, inaccurate refraction, and patient dissatisfaction in 22 (68.75%), 4 (12.5%), 3 (9.37%), 2 (6.25%), and 1 (3.12%) case, respectively. The most common indication for ICL exchange/explantation in the KC group was inaccurate vault sizing in 11 patients (78.57%), inaccurate refraction in 2 patients (14.28%), and patient dissatisfaction postoperatively in 1 (7.14%) case. CONCLUSION: ICL implantation results in predictable refractive outcomes over the long term with exchange/explantation rates comparable to previous literature. Improper vault size is the most common cause of ICL exchange/explantation among patients with or without KC.
引用
收藏
页码:1714 / 1720
页数:7
相关论文
共 47 条
  • [1] Toric ICL Implantation After Sequential Intracorneal Ring Segments Implantation and Corneal Cross-linking in Keratoconus: 2-Year Follow-up
    Abdelmassih, Youssef
    el-Khoury, Sylvain
    Chelala, Elias
    Slim, Elise
    Cherfan, Carole G.
    Jarade, Elias
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (09) : 610 - +
  • [2] Posterior chamber collagen copolymer phakic intraocular lenses to correct myopia: Five-year follow-up
    Alfonso, Jose F.
    Baamonde, Begona
    Fernandez-Vega, Luis
    Fernandes, Paulo
    Gonzalez-Meijome, Jose M.
    Montes-Mico, Robert
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (05) : 873 - 880
  • [3] Visian Implantable Collamer Lens Behavior in Descemet Membrane Endothelial Keratoplasty Surgery
    Alio del Barrio, Jorge L.
    D'Oria, Francesco
    Alio, Jorge L.
    [J]. CORNEA, 2021, 40 (01) : 113 - 115
  • [4] Causes of Phakic Implantable Collamer Lens Explantation/Exchange at King Khaled Eye Specialist Hospital
    AlSabaani, Nasser A.
    Behrens, Ashley
    Jastanieah, Sabah
    Al Malki, Salem
    Al Jindan, Mohanna
    Al Motowa, Saeed
    [J]. MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2016, 23 (04) : 293 - 295
  • [5] Safety and Visual Outcome of Visian Toric ICL Implantation after Corneal Collagen Cross-Linking in Keratoconus: Up to 2 Years of Follow-Up
    Antonios, Rafic
    Dirani, Ali
    Fadlallah, Ali
    Chelala, Elias
    Hamade, Adib
    Cherfane, Carole
    Jarade, Elias
    [J]. JOURNAL OF OPHTHALMOLOGY, 2015, 2015
  • [6] Arora R., 2016, Delhi J Ophthalmol, V27, P38
  • [7] Safety and efficacy of toric implantable collamer lens V4c model - A retrospective South Indian study
    Chaitanya, S. Ravi
    Anitha, Venugopal
    Ravindran, Meenakshi
    Ghorpade, Aditya
    Rengappa, Ramakrishnan
    Uduman, Mahammed Sithiq
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (12) : 3006 - 3011
  • [8] Spontaneous rotation of a toric implantable collamer lens related to abnormal ciliary body morphology: a case report
    Chen, Qian
    Zeng, Qingyan
    Wang, Zheng
    Pan, Chao
    Lei, Xiaohua
    Tan, Weina
    [J]. BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [9] Clinical Prediction of Excessive Vault After Implantable Collamer Lens Implantation Using Ciliary Body Morphology
    Chen, Qian
    Tan, Weina
    Lei, Xiaohua
    Pan, Chao
    Jin, Lina
    Zeng, Qingyan
    Wang, Zheng
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2020, 36 (06) : 380 - +
  • [10] Comparison of early changes in and factors affecting vault following posterior chamber phakic Implantable Collamer Lens implantation without and with a central hole (ICL V4 and ICL V4c)
    Chen, Xun
    Miao, Huamao
    Naidu, Rajeev Krishnan
    Wang, Xiaoying
    Zhou, Xingtao
    [J]. BMC OPHTHALMOLOGY, 2016, 16