Final results from a pilot study with an implantable loop recorder to determine the etiology of syncope in patients with negative noninvasive and invasive testing
被引:99
作者:
Krahn, AD
论文数: 0引用数: 0
h-index: 0
机构:
Univ Western Ontario, Div Cardiol, London, ON, CanadaUniv Western Ontario, Div Cardiol, London, ON, Canada
Krahn, AD
[1
]
Klein, GJ
论文数: 0引用数: 0
h-index: 0
机构:
Univ Western Ontario, Div Cardiol, London, ON, CanadaUniv Western Ontario, Div Cardiol, London, ON, Canada
Klein, GJ
[1
]
Yee, R
论文数: 0引用数: 0
h-index: 0
机构:
Univ Western Ontario, Div Cardiol, London, ON, CanadaUniv Western Ontario, Div Cardiol, London, ON, Canada
Yee, R
[1
]
Norris, C
论文数: 0引用数: 0
h-index: 0
机构:
Univ Western Ontario, Div Cardiol, London, ON, CanadaUniv Western Ontario, Div Cardiol, London, ON, Canada
Norris, C
[1
]
机构:
[1] Univ Western Ontario, Div Cardiol, London, ON, Canada
Twenty-four patients with recurrent unexplained syncope and negative tilt and electrophysiologic testing underwent implantation of the implantable loop recorder, with recurrence of syncope in 21 patients 5.1 ± 4.8 months after device implantation. Eighteen of the 21 had a treatable diagnosis, with arrhythmias in 11. Treatment resulted in resolution of syncope in most patients during long-term follow-up.