Microneedle-Based Detection of Ketone Bodies along with Glucose and Lactate: Toward Real-Time Continuous Interstitial Fluid Monitoring of Diabetic Ketosis and Ketoacidosis

被引:190
作者
Teymourian, Hazhir [1 ]
Moonla, Chochanon [1 ,3 ]
Tehrani, Farshad [1 ]
Vargas, Eva [1 ]
Aghavali, Reza [1 ]
Barfidokht, Abbas [1 ]
Tangkuaram, Tanin [3 ]
Mercier, Patrick P. [2 ]
Dassau, Eyal [4 ]
Wang, Joseph [1 ]
机构
[1] Univ Calif San Diego, Dept Nanoengn, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Dept Elect & Comp Engn, La Jolla, CA 92093 USA
[3] Maejo Univ, Fac Sci, Appl Chem Program, Chiang Mai 50290, Thailand
[4] Harvard Univ, Harvard A John Paulson Sch Engn & Appl Sci, Cambridge, MA 02138 USA
关键词
ELECTROCATALYTIC OXIDATION; CARBON NANOTUBES; IN-VIVO; BIOSENSOR; ENZYME; ELECTRODES; SENSOR; NADH; PREVENTION; MEMBRANE;
D O I
10.1021/acs.analchem.9b05109
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Diabetic ketoacidosis (DKA), a severe complication of diabetes mellitus with potentially fatal consequences, is characterized by hyperglycemia and metabolic acidosis due to the accumulation of ketone bodies, which requires people with diabetes to monitor both glucose and ketone bodies. However, despite major advances in diabetes management mainly since the emergence of new-generation continuous glucose monitoring (CGM) devices capable of in vivo monitoring of glucose directly in the interstitial fluid (ISF), the continuous monitoring of ketone bodies is yet to be addressed. Here, we present the first use of a real-time continuous ketone bodies monitoring (CKM) microneedle platform. The system is based on the electrochemical monitoring of beta-hydroxybutyrate (HB) as the dominant biomarker of ketone formation. Such real-time HB detection has been realized using the beta-hydroxybutyrate dehydrogenase (HBD) enzymatic reaction and by addressing the major challenges associated with the stable confinement of the enzyme/cofactor couple (HBD/NAD(+)) and with a stable and selective low-potential fouling-free anodic detection of NADH. The resulting CKM microneedle device displays an attractive analytical performance, with high sensitivity (with low detection limit, 50 mu M), high selectivity in the presence of potential interferences, along with good stability during prolonged operation in artificial ISF. The potential applicability of this microneedle sensor toward minimally invasive monitoring of ketone bodies has been demonstrated in a phantom gel skin-mimicking model. The ability to detect HB along with glucose and lactate on a single microneedle array has been demonstrated. These findings pave the way for CKM and for the simultaneous microneedle-based monitoring of multiple diabetes-related biomarkers toward a tight glycemic control.
引用
收藏
页码:2291 / 2300
页数:10
相关论文
共 36 条
  • [1] Tattoo-Based Noninvasive Glucose Monitoring: A Proof-of-Concept Study
    Bandodkar, Amay J.
    Jia, Wenzhao
    Yardimci, Ceren
    Wang, Xuan
    Ramirez, Julian
    Wang, Joseph
    [J]. ANALYTICAL CHEMISTRY, 2015, 87 (01) : 394 - 398
  • [2] Modified electrodes for NADH oxidation and dehydrogenase-based biosensors
    Bartlett, PN
    Simon, E
    Toh, CS
    [J]. BIOELECTROCHEMISTRY, 2002, 56 (1-2) : 117 - 122
  • [3] Room Temperature Ionic Liquids Meet Biomolecules: A Microscopic View of Structure and Dynamics
    Benedetto, Antonio
    Ballone, Pietro
    [J]. ACS SUSTAINABLE CHEMISTRY & ENGINEERING, 2016, 4 (02): : 392 - 412
  • [4] STUDY OF A REAGENTLESS LACTATE ELECTRODE
    BLAEDEL, WJ
    JENKINS, RA
    [J]. ANALYTICAL CHEMISTRY, 1976, 48 (08) : 1240 - 1247
  • [5] REAGENTLESS ENZYME ELECTRODES FOR ETHANOL, LACTATE, AND MALATE
    BLAEDEL, WJ
    ENGSTROM, RC
    [J]. ANALYTICAL CHEMISTRY, 1980, 52 (11) : 1691 - 1697
  • [6] SYNTHETIC INTERSTITIAL FLUID FOR ISOLATED MAMMALIAN TISSUE
    BRETAG, AH
    [J]. LIFE SCIENCES PART 1 PHYSIOLOGY AND PHARMACOLOGY AND PART 2 BIOCHEMISTRY GENERAL AND MOLECULAR BIOLOGY, 1969, 8 (5P1): : 319 - &
  • [7] A Swellable Microneedle Patch to Rapidly Extract Skin Interstitial Fluid for Timely Metabolic Analysis
    Chang, Hao
    Zheng, Mengjia
    Yu, Xiaojun
    Aung Than
    Seeni, Razina Z.
    Kang, Rongjie
    Tian, Jingqi
    Duong Phan Khanh
    Liu, Linbo
    Chen, Peng
    Xu, Chenjie
    [J]. ADVANCED MATERIALS, 2017, 29 (37)
  • [8] PLASTICIZED POLY(VINYL CHLORIDE) AS A PERMSELECTIVE BARRIER MEMBRANE FOR HIGH-SELECTIVITY AMPEROMETRIC SENSORS AND BIOSENSORS
    CHRISTIE, IM
    TRELOAR, PH
    VADGAMA, P
    [J]. ANALYTICA CHIMICA ACTA, 1992, 269 (01) : 65 - 73
  • [9] Ketone bodies monitoring
    Federici, Marco Orsini
    Benedetti, Massimo Massi
    [J]. DIABETES RESEARCH AND CLINICAL PRACTICE, 2006, 74 : S77 - S81
  • [10] Development of a commercial amperometric biosensor electrode for the ketone D-3-hydroxybutyrate
    Forrow, NJ
    Sanghera, GS
    Walters, SJ
    Watkin, JL
    [J]. BIOSENSORS & BIOELECTRONICS, 2005, 20 (08) : 1617 - 1625