Comparison of Iotrolan 320 and Iohexol 350 in cardiac angiography: a randomised double-blind clinical study

被引:3
作者
Mezilis, N [1 ]
Salame, MY [1 ]
Dyet, JF [1 ]
Arafa, SO [1 ]
Oakley, GDG [1 ]
Cumberland, DC [1 ]
机构
[1] No Gen Hosp, Dept Cardiol, Sheffield S5 7AU, S Yorkshire, England
关键词
contrast media; coronary angiography; haemodynamics; EGG; adverse reactions;
D O I
10.1016/S0720-048X(97)00131-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: A double-blind randomised study was conducted in two British centres, to evaluate the safety, tolerance and efficacy of the new dimeric non-ionic contrast medium Iotrolan 320 in comparison with the monomeric non-ionic compound Iohexol 350 in coronary angiography. Methods and Material: 120 patients were randomised to receive either Iotrolan at a concentration of 320 mgI/ml or Iohexol at a concentration of 350 mgI/ml, during selective coronary angiography and left ventriculography. The variables measured were: maximum increase of the left ventricular end-diastolic pressure up to 6 min after ventriculography, haemodynamic and electrocardiographic variables, arrhythmogenicity, clinical laboratory parameters, tolerance, adverse events and efficacy. Results: Iotrolan resulted in a smaller change of left ventricular end-diastolic pressure compared to Iohexol, but the difference was not statistically significant. Transient changes in left ventricular systolic pressure, intra-arterial systolic pressure, intra-arterial diastolic pressure, and in electrocardiographic parameters, occurred after the injections, but they were not clinically significant. Changes in the clinical laboratory markers from baseline values were comparable between the two groups and confirmed good renal and hepatic tolerance. During the left ventriculogram, Iotrolan resulted in less symptoms compared to Iohexol (P = 0.002). Adverse events, which were mild or moderate in most cases, were observed with no statistical difference between the two agents. The contrast quality of both agents was good with no statistical difference. Conclusion: This study did not show a significant difference between Iotrolan 320 and Iohexol 350 with regard to cardiovascular safety or patient tolerance, except for a minor difference in the intensity of heat/warmth sensation. (C) 1998 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:171 / 175
页数:5
相关论文
共 12 条
  • [1] NEPHROTOXICITY OF IONIC AND NON-IONIC CONTRAST-MEDIA IN AORTO-FEMORAL ANGIOGRAPHY
    ALBRECHTSSON, U
    HULTBERG, B
    LARUSDOTTIR, H
    NORGREN, L
    [J]. ACTA RADIOLOGICA-DIAGNOSIS, 1985, 26 (05): : 615 - 618
  • [2] CONTRAST AGENTS FOR CARDIAC ANGIOGRAPHY - EFFECTS OF A NONIONIC AGENT VS A STANDARD IONIC AGENT
    BETTMANN, MA
    BOURDILLON, PD
    BARRY, WH
    BRUSH, KA
    LEVIN, DC
    [J]. RADIOLOGY, 1984, 153 (03) : 583 - 587
  • [3] IOMEPROL AND IOPAMIDOL IN CARDIAC ANGIOGRAPHY - A RANDOMIZED, DOUBLE-BLIND, PARALLEL-GROUP COMPARISON
    FATTORI, R
    PIVA, R
    SCHICCHI, F
    PANCRAZI, A
    GABRIELLI, G
    MARZOCCHI, A
    PIOVACCARI, G
    BLANDINI, A
    MAGNANI, B
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 1994, 18 : S61 - S66
  • [4] CLINICAL SUPERIORITY OF A NEW NONIONIC CONTRAST AGENT (IOPAMIDOL) FOR CARDIAC ANGIOGRAPHY
    GERTZ, EW
    WISNESKI, JA
    CHIU, D
    AKIN, JR
    HU, C
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 5 (02) : 250 - 258
  • [5] NEPHROTOXICITY OF IONIC AND NON-IONIC CONTRAST MATERIAL IN DIGITAL VASCULAR IMAGING AND SELECTIVE RENAL ARTERIOGRAPHY
    KHOURY, GA
    HOPPER, JC
    VARGHESE, Z
    FARRINGTON, K
    DICK, R
    IRVING, JD
    SWENY, P
    FERNANDO, ON
    MOORHEAD, JF
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1983, 56 (669) : 631 - 635
  • [6] A LARGE TRIAL OF INTRAVENOUS CONRAY 325 AND NIOPAM 300 TO ASSESS IMMEDIATE AND DELAYED-REACTIONS
    MCCULLOUGH, M
    DAVIES, P
    RICHARDSON, R
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1989, 62 (735) : 260 - 265
  • [7] DELAYED-REACTIONS TO UROGRAPHIC CONTRAST-MEDIA
    PANTO, PN
    DAVIES, P
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (697) : 41 - 44
  • [8] CONTRAST MEDIA-INDUCED VENTRICULAR-FIBRILLATION - A COMPARISON OF HYPAQUE-76, HEXABRIX, AND OMNIPAQUE
    PIAO, ZE
    MURDOCK, DK
    HWANG, MH
    RAYMOND, RM
    SCANLON, PJ
    [J]. INVESTIGATIVE RADIOLOGY, 1988, 23 (06) : 466 - 470
  • [9] ABSENCE OF MYOCARDIAL BIOCHEMICAL TOXICITY WITH A NONIONIC CONTRAST AGENT (IOPAMIDOL)
    WISNESKI, JA
    GERTZ, EW
    NEESE, RA
    MORRIS, DL
    [J]. AMERICAN HEART JOURNAL, 1985, 110 (03) : 609 - 617
  • [10] COMPARISON OF LOW OSMOLALITY IONIC (IOXAGLATE) VERSUS NONIONIC (IOPAMIDOL) CONTRAST-MEDIA IN CARDIAC ANGIOGRAPHY
    WISNESKI, JA
    GERTZ, EW
    DAHLGREN, M
    MUSLIN, A
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1989, 63 (07) : 489 - 495