Image quality assessment of clinically-applied CBCT protocols using a QAT phantom

被引:10
作者
Elkhateeb, Sara M. [1 ]
Torgersen, Gerald R. [2 ]
Arnout, Eman A. [1 ]
机构
[1] Ain Shams Univ, Dept Oral Med Periodontol Diag & Oral Radiol, Fac Dent, Cairo, Egypt
[2] Univ Oslo, Fac Dent, Dept Maxillofacial Radiol, Oslo, Norway
关键词
phantom; quality; clinically protocols; modulation transfer functions; CBCT; MODULATION TRANSFER-FUNCTION; TOMOGRAPHY;
D O I
10.1259/dmfr.20160075
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study has two main purposes: (1) to evaluate the effect of various clinically applied protocols [changing field of view (FOV), voxel size and tube voltage (kVp)] on CS 9300 CBCT (CareStream SM 749, Rochester, NY) image quality using its quality assurance test (QAT) phantom and (2) to evaluate the efficacy of a newly-designed prototype plugin on ImageJ (National Institutes of Health, Bethesda, MD) which was introduced to measure modulation transfer function (MTF) using a modified slanted-edge method. Methods: Using a specifically constructed QAT phantom, five image quality parameters were assessed-image uniformity, signal-to-noise ratio, contrast, position checking and the MTF-for ten variables, clinically applied protocols on a CS 9300 PREMIUM three-dimensional CBCT device. Results: With FOV and voxel size fixed, high-dose protocols resulted in less image noise and more uniformity. On the other hand, less image uniformity was achieved with less kVp. Moreover, high-dose protocols resulted in a high contrast-to-noise ratio (CNR). There were significant differences in CNR between 60 and 70 kVp as well as between 70 and 90 kVp. Our study identified no difference between MTF and either voxel size or FOV. Conclusions: The image quality of the CS 9300 CBCT varied with variability in exposure protocols and different voxel sizes. The negative association between greater spatial resolution (smaller voxel size) and the MTF shows that the slanted edge method is not ideal for MTF evaluation of CBCT and is therefore not recommended for using it for this purpose.
引用
收藏
页数:11
相关论文
共 19 条
[1]   Quantitative performance characterization of image quality and radiation dose for a CS 9300 dental cone beam computed tomography machine [J].
Abouei, Elham ;
Lee, Sierra ;
Ford, Nancy L. .
JOURNAL OF MEDICAL IMAGING, 2015, 2 (04)
[2]   Image quality assessment of three cone beam CT machines using the SEDENTEXCT CT phantom [J].
Bamba, J. ;
Araki, K. ;
Endo, A. ;
Okano, T. .
DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (08)
[3]   Ex vivo detection of mesiobuccal canals in maxillary molars using CBCT at four different isotropic voxel dimensions [J].
Bauman, R. ;
Scarfe, W. ;
Clark, S. ;
Morelli, J. ;
Scheetz, J. ;
Farman, A. .
INTERNATIONAL ENDODONTIC JOURNAL, 2011, 44 (08) :752-758
[4]   Contrast-to-noise ratio difference in small field of view cone beam computed tomography machines [J].
Bechara, Boulos ;
McMahan, Clyde A. ;
Moore, William S. ;
Noujeim, Marcel ;
Geha, Hassem ;
Teixeira, Fabricio B. .
JOURNAL OF ORAL SCIENCE, 2012, 54 (03) :227-232
[5]   Impact of a Reduced Tube Voltage on CT Angiography and Radiation Dose Results of the PROTECTION I Study [J].
Bischoff, Bernhard ;
Hein, Franziska ;
Meyer, Tanja ;
Hadamitzky, Martin ;
Martinoff, Stefan ;
Schoemig, Albert ;
Hausleiter, Joerg .
JACC-CARDIOVASCULAR IMAGING, 2009, 2 (08) :940-946
[6]  
Brahme A., 2014, Comprehensive biomedical physics
[7]   Simple method for modulation transfer function determination of digital imaging detectors from edge images [J].
Buhr, E ;
Günther-Kohfahl, S ;
Neitzel, U .
MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 :877-884
[8]   A SIMPLE METHOD FOR DETERMINING THE MODULATION TRANSFER-FUNCTION IN DIGITAL RADIOGRAPHY [J].
FUJITA, H ;
TSAI, DY ;
ITOH, T ;
DOI, K ;
MORISHITA, J ;
UEDA, K ;
OHTSUKA, A .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (01) :34-39
[9]   Basic principles for use of dental cone beam computed tomography: consensus guidelines of the European Academy of Dental and Maxillofacial Radiology [J].
Horner, K. ;
Islam, M. ;
Flygare, L. ;
Tsiklakis, K. ;
Whaites, E. .
DENTOMAXILLOFACIAL RADIOLOGY, 2009, 38 (04) :187-195
[10]  
Lehmann J, 2012, MODERN PRACTICE RAD, P291