Diagnostics of the soft x-ray emission in a plasma focus device

被引:0
|
作者
Gasparyan, PD [1 ]
Demin, AN [1 ]
Subbotin, AN [1 ]
Usenko, PL [1 ]
机构
[1] All Russian Sci Res Inst Expt Phys, VNIIEF, RFNC, Russian Fed Nucl Ctr, Nizhnii Novgorod 607190, Russia
来源
11TH IEEE INTERNATIONAL PULSED POWER CONFERENCE - DIGEST OF TECHNICAL PAPERS, VOLS. 1 & 2 | 1997年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Experimental results of the soft x-ray spectra investigation; from a hot plasma produced by impulse discharge of a dense plasma focus in pure neon are presented. The spectral-energy characteristics of x-ray emission were measured in the photon energy range of (0.5-5.0) keV with the help of thin absorber filters set and silicon semiconductor p-i-n detectors-SPPD11-04. A study was made at the filling gas pressure P-Ne=(2.0-6.0) Torr and at the stored capacitor bank energy W=(15-21) kJ. High degree of monochromatization far the soft x-ray emission: (similar to 90 %) was obtained According to: the experimental data characteristic plasma electron temperature in the time duration of x-ray pulse tau(1/2)=(10-100) ns has been estimated as T-e similar to(0.2-0.3) keV. The plasma parameters obtained are compared with-the results of computer simulation of the emission process.
引用
收藏
页码:1010 / 1015
页数:6
相关论文
共 50 条
  • [1] Characterization of the Soft X-Ray Emission from the APF Plasma Focus Device Operated in Neon
    Baghdadi, R.
    Amrollahi, R.
    Etaati, G. R.
    Habibi, M.
    Roomi, A.
    JOURNAL OF FUSION ENERGY, 2011, 30 (02) : 137 - 143
  • [2] Characterization of the Soft X-Ray Emission from the APF Plasma Focus Device Operated in Neon
    R. Baghdadi
    R. Amrollahi
    G. R. Etaati
    M. Habibi
    A. Roomi
    Journal of Fusion Energy, 2011, 30 : 137 - 143
  • [3] Soft x-ray emission in the neon gas puff plasma focus
    Yanagidaira, T
    Shimoda, K
    Ono, Y
    Hirano, K
    PHYSICS OF PLASMAS, 1999, 6 (12) : 4679 - 4684
  • [4] Variation of soft X-ray emission with gas pressure in a plasma focus
    Ng, CM
    Moo, SP
    Wong, CS
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 1998, 26 (04) : 1146 - 1153
  • [5] Current sheath curvature correlation with the neon soft x-ray emission from plasma focus device
    Zhang, T
    Lin, X
    Chandra, KA
    Tan, TL
    Springham, SV
    Patran, A
    Lee, P
    Lee, S
    Rawat, RS
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 2005, 14 (02): : 368 - 374
  • [6] Comparative study of soft x-ray emission characteristics in a low energy dense plasma focus device
    Bhuyan, H
    Mohanty, SR
    Neog, NK
    Bujarbarua, S
    Rout, RK
    JOURNAL OF APPLIED PHYSICS, 2004, 95 (06) : 2975 - 2981
  • [7] Soft X-ray emission from preionized He plasma in a 3.3 kJ Mather type plasma focus device
    Khan, H. U.
    Shafiq, M.
    Hussain, S. S.
    Ahmad, S.
    Zakaullah, M.
    PLASMA DEVICES AND OPERATIONS, 2009, 17 (04): : 257 - 264
  • [8] Diagnostics of soft X-ray emission from the plasma of a fast capillary discharge
    Ostashev, V. I.
    Gafarov, A. M.
    Politov, V. Yu.
    Shushlebin, A. N.
    Antonova, L. V.
    Gilev, O. N.
    Safronov, A. A.
    Komissarov, A. V.
    PLASMA PHYSICS REPORTS, 2006, 32 (06) : 489 - 499
  • [9] Diagnostics of soft X-ray emission from the plasma of a fast capillary discharge
    V. I. Ostashev
    A. M. Gafarov
    V. Yu. Politov
    A. N. Shushlebin
    L. V. Antonova
    O. N. Gilev
    A. A. Safronov
    A. V. Komissarov
    Plasma Physics Reports, 2006, 32 : 489 - 499