4D Acoustoelectric Imaging of Current Sources in a Human Head Phantom

被引:0
|
作者
Qin, Yexian [1 ]
Ingram, Pier [1 ]
Burton, Alex [2 ]
Witte, Russell S. [1 ,2 ,3 ]
机构
[1] Univ Arizona, Dept Med Imaging, Tucson, AZ 85724 USA
[2] Univ Arizona, Dept Biomed Engn, Tucson, AZ 85721 USA
[3] Univ Arizona, Coll Opt Sci, Tucson, AZ 85721 USA
来源
2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS) | 2016年
关键词
Function brain imaging; inverse problem; acoustoelectric; Ultrasound; ultrasound current source density imaging; EEG; EcoG; Electroencephalography; evoked potentials; DENSITY; TOMOGRAPHY; SIMULATION; CORTEX;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electrical brain mapping typically suffers from poor spatial resolution due to the uncertain spread of electric field lines through the brain and skull. To overcome this limitation, we propose 4D acoustoelectric brain imaging (ABI) for mapping current densities at a spatial resolution confined to the ultrasound (US) focal spot. Acoustoelectric (AE) imaging exploits an interaction between a pressure wave and tissue resistivity. It has been used to dynamically map the cardiac activation wave in the live rabbit heart. Our long-term goal is to extend this technique for electrical mapping of the human brain. In this study, we developed a human-size head and brain phantom to test and optimize ABI for detecting an embedded "EEG-Iike" electrical current. Detection thresholds for current sources more than 15 mm below the surface of the brain phantom was less than 1 mA/cm(2) using a 0.5-MHz or 1 MHz single element transducer and copper recording wires. Further optimization of ABI could enable detection of small neural currents in the brain and lead to a new modality for functional brain imaging.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] The development of a population of 4D pediatric XCAT phantoms for imaging research and optimization
    Segars, W. P.
    Norris, Hannah
    Sturgeon, Gregory M.
    Zhang, Yakun
    Bond, Jason
    Minhas, Anum
    Tward, Daniel J.
    Ratnanather, J. T.
    Miller, M. I.
    Frush, D.
    Samei, E.
    MEDICAL PHYSICS, 2015, 42 (08) : 4719 - 4726
  • [32] Reference values for 4D flow magnetic resonance imaging of the portal venous system
    Huang, Andrew
    Roberts, Grant S.
    Roldan-Alzate, Alejandro
    Wieben, Oliver
    Reeder, Scott B.
    Oechtering, Thekla H.
    ABDOMINAL RADIOLOGY, 2023, 48 (06) : 2049 - 2059
  • [33] A new high channels density ultrasound platform for advanced 4D cardiac imaging
    Petrusca, Lorena
    Varray, Francois
    Souchon, Remi
    Bernard, Adeline
    Chapelon, Jean-Yves
    Liebgott, Herve
    N'Djin, W. Apoutou
    Viallon, Magalie
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [34] The development of a population of 4D pediatric XCAT phantoms for CT imaging research and optimization
    Norris, Hannah
    Zhang, Yakun
    Frush, Jack
    Sturgeon, Gregory M.
    Minhas, Anum
    Tward, Daniel J.
    Ratnanather, J. Tilak
    Miller, M. I.
    Frush, Donald
    Samei, Ehsan
    Segars, W. Paul
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [35] Population of anatomically variable 4D XCAT adult phantoms for imaging research and optimization
    Segars, W. P.
    Bond, Jason
    Frush, Jack
    Hon, Sylvia
    Eckersley, Chris
    Williams, Cameron H.
    Feng, Jianqiao
    Tward, Daniel J.
    Ratnanather, J. T.
    Miller, M. I.
    Frush, D.
    Samei, E.
    MEDICAL PHYSICS, 2013, 40 (04)
  • [36] Quantifying the impact of respiratory-gated 4D CT acquisition on thoracic image quality: A digital phantom study
    Bernatowicz, K.
    Keall, P.
    Mishra, P.
    Knopf, A.
    Lomax, A.
    Kipritidis, J.
    MEDICAL PHYSICS, 2015, 42 (01) : 324 - 334
  • [37] Head-to-head comparison among 18F-choline PET/CT, 4D contrast-enhanced CT, and 18F-choline PET/4D contrast-enhanced CT in the detection of hyperfunctioning parathyroid glands: a systematic review and meta-analysis
    Piccardo, Arnoldo
    Bottoni, Gianluca
    Boccalatte, Luis Alejandro
    Camponovo, Chiara
    Musumeci, Martina
    Bacigalupo, Lorenzo
    Collaud, Carlos
    Ugolini, Martina
    Fiz, Francesco
    Trimboli, Pierpaolo
    ENDOCRINE, 2021, 74 (02) : 404 - 412
  • [38] Extension of the NCAT phantom for the investigation of intra-fraction respiratory motion in IMRT using 4D Monte Carlo
    McGurk, Ross
    Seco, Joao
    Riboldi, Marco
    Wolfgang, John
    Segars, Paul
    Paganetti, Harald
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (05) : 1475 - 1490
  • [39] A proto-type design of a real-tissue phantom for the validation of deformation algorithms and 4D dose calculations
    Szegedi, M.
    Rassiah-Szegedi, P.
    Fullerton, G.
    Wang, B.
    Salter, B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (13) : 3685 - 3699
  • [40] Acoustic micro-tapping for non-contact 4D imaging of tissue elasticity
    Ambrozinski, Lukasz
    Song, Shaozhen
    Yoon, Soon Joon
    Pelivanov, Ivan
    Li, David
    Gao, Liang
    Shen, Tueng T.
    Wang, Ruikang K.
    O'Donnell, Matthew
    SCIENTIFIC REPORTS, 2016, 6