Use of spiral CT and the contrast medium iohexol to determine in one session aortorenal morphology and the relative glomerular filtration rate of each kidney

被引:22
作者
Frennby, B [1 ]
Almén, T [1 ]
机构
[1] Malmo Univ Hosp, Dept Diagnost Radiol, S-20502 Malmo, Sweden
关键词
glomerular filtration rate; contrast media; spiral CT;
D O I
10.1007/s003300100831
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to determine the relative glomerular filtration rate (GFR), i.e. the GFR of each kidney in percent of total GFR, by spiral CT. In 41 patients, who were part of a follow-up program after endoluminal stent grafting of aortic aneurysm, spiral CT with the contrast medium iohexol was used to evaluate the morphology of the aorta and kidneys. The opportunity was taken to utilize the already injected iohexol to determine the relative GFR with an extra CT sequence. In each patient two determinations were made, 6 or 12 months apart. The amount of a GFR marker accumulating in Bowman's space, tubuli, and renal pelvis within 2-3 min after i.v. injection, before any marker had left the kidney via the ureter, was defined as proportional to the GFR of that kidney. The renal accumulation of iohexol was obtained by spiral CT using 10-mm collimation and a table speed of 10 mm/s (pitch ratio 1:1) from the upper to the lower poles. The correlation coefficient between the relative GFR of each kidney determined at the first and second examination was excellent (r = 0.99) with a median (range) difference of 1% (0-6%) of total GFR. The radiation dose calculated as the mean absorbed dose to the kidneys was 50 mGy and the effective dose 5 mSv. The morphology of aorta and kidneys and the relative GFR of each kidney can be determined in one session with spiral CT using iohexol as both angiographic contrast medium and as a GFR marker. It is also possible to take some plasma samples in the same session to determine iohexol concentration to calculate the body clearance of iohexol (or take plasma and urine samples to calculate the renal clearance of iohexol).
引用
收藏
页码:2270 / 2277
页数:8
相关论文
共 25 条
[1]   ESTIMATION OF GLOMERULAR-FILTRATION RATE USING CHROMIUM-51 ETHYLENE DIAMINE TETRAACETIC ACID AND TC-99M DIETHYLENE TRIAMINE PENTA-ACETIC ACID [J].
BIGGI, A ;
VIGLIETTI, A ;
FARINELLI, MC ;
BONADA, C ;
CAMUZZINI, G .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1995, 22 (06) :532-536
[2]   Functional renal perfusion imaging with colour mapping:: is it a useful adjunct to spiral CT of in the assessment of abdominal aortic aneurysm (AAA)? [J].
Blomley, MJK ;
McBride, A ;
Mohammedtagi, S ;
Albrecht, T ;
Harvey, CJ ;
Jäger, R ;
Standfield, NJ ;
Dawson, P .
EUROPEAN JOURNAL OF RADIOLOGY, 1999, 30 (03) :214-220
[3]  
BLOMLEY MJK, 1994, INVEST RADIOL, V29, P232
[4]   GFR measurement with iohexol and 51Cr-EDTA.: A comparison of the two favoured GFR markers in Europe [J].
Brandstrom, E ;
Grzegorczyk, A ;
Jacobsson, L ;
Friberg, P ;
Lindahl, A ;
Aurell, M .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1998, 13 (05) :1176-1182
[5]   IOHEXOL CLEARANCE FOR THE DETERMINATION OF GLOMERULAR-FILTRATION RATE IN CLINICAL-PRACTICE - EVIDENCE FOR A NEW GOLD STANDARD [J].
BROWN, SCW ;
OREILLY, PH .
JOURNAL OF UROLOGY, 1991, 146 (03) :675-679
[6]   Delayed allergy-like reactions to X-ray contrast media: mechanistic considerations [J].
Christiansen, C ;
Pichler, WJ ;
Skotland, T .
EUROPEAN RADIOLOGY, 2000, 10 (12) :1965-1975
[7]  
FRENNBY B, 1995, ACTA RADIOL, V36, P410
[8]  
Frennby B, 1997, SCAND J UROL NEPHROL, V31, P1
[9]  
GASPARI F, 1995, J AM SOC NEPHROL, V6, P257