Improving the accuracy of smart devices to measure noise exposure

被引:44
作者
Roberts, Benjamin [1 ]
Kardous, Chucri [2 ]
Neitzel, Richard [1 ]
机构
[1] Univ Michigan, Sch Publ Hlth, Dept Environm Hlth Sci, Ann Arbor, MI 48109 USA
[2] NIOSH, Cincinnati, OH 45226 USA
关键词
Emerging technology; noise exposure; smartphones; smart devices;
D O I
10.1080/15459624.2016.1183014
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Occupational noise exposure is one of the most frequent hazards present in the workplace; up to 22 million workers have potentially hazardous noise exposures in the U.S. As a result, noise-induced hearing loss is one of the most common occupational injuries in the U.S. Workers in manufacturing, construction, and the military are at the highest risk for hearing loss. Despite the large number of people exposed to high levels of noise at work, many occupations have not been adequately evaluated for noise exposure. The objective of this experiment was to investigate whether or not iOS smartphones and other smart devices (Apple iPhones and iPods) could be used as reliable instruments to measure noise exposures. For this experiment three different types of microphones were tested with a single model of iPod and three generations of iPhones: the internal microphones on the device, a low-end lapel microphone, and a high-end lapel microphone marketed as being compliant with the International Electrotechnical Commission's (IEC) standard for a Class 2-microphone. All possible combinations of microphones and noise measurement applications were tested in a controlled environment using several different levels of pink noise ranging from 60-100 dBA. Results were compared to simultaneous measurements made using a Type 1 sound level measurement system. Analysis of variance and Tukey's honest significant difference (HSD) test were used to determine if the results differed by microphone or noise measurement application. Levels measured with external microphones combined with certain noise measurement applications did not differ significantly from levels measured with the Type 1 sound measurement system. Results showed that it may be possible to use iOS smart phones and smart devices, with specific combinations of measurement applications and calibrated external microphones, to collect reliable, occupational noise exposure data under certain conditions and within the limitations of the device. Further research is needed to determine how these devices compare to traditional noise dosimeter under real-world conditions.
引用
收藏
页码:840 / 846
页数:7
相关论文
共 15 条
[1]  
[Anonymous], 2013, International Conference on Distributed Computing and Internet Technology, DOI DOI 10.1007/978-3-642-36071-8
[2]   Crowdsourcing, citizen sensing and sensor web technologies for public and environmental health surveillance and crisis management: trends, OGC standards and application examples [J].
Boulos, Maged N. Kamel ;
Resch, Bernd ;
Crowley, David N. ;
Breslin, John G. ;
Sohn, Gunho ;
Burtner, Russ ;
Pike, William A. ;
Jezierski, Eduardo ;
Chuang, Kuo-Yu Slayer .
INTERNATIONAL JOURNAL OF HEALTH GEOGRAPHICS, 2011, 10
[3]  
Dayton Audio, IMM 6 CAL MEAS MICR
[4]  
IEC, EL SOUND LEV MET 1
[5]   Evaluation of smartphone sound measurement applications [J].
Kardous, Chucri A. ;
Shaw, Peter B. .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2014, 135 (04) :EL186-EL192
[6]  
MicW, I436 US MAN
[7]  
Murphy E., EXPLORING ACCURACY S
[8]   Testing the accuracy of smartphones and sound level meter applications for measuring environmental noise [J].
Murphy, Enda ;
King, Eoin A. .
APPLIED ACOUSTICS, 2016, 106 :16-22
[9]   Sound level measurements using smartphone "apps": Useful or inaccurate? [J].
Nast, Daniel R. ;
Speer, William S. ;
Le Prell, Colleen G. .
NOISE & HEALTH, 2014, 16 (72) :251-256
[10]  
National Institute for Occupational Safety and Health (NIOSH), CRIT REC STAND OCC N