Factors that affect quantification of diode array data in comprehensive two-dimensional liquid chromatography using chemometric data analysis

被引:28
|
作者
Bailey, Hope P. [1 ]
Rutan, Sarah C. [1 ]
Carr, Peter W. [2 ]
机构
[1] Virginia Commonwealth Univ, Dept Chem, Richmond, VA 23284 USA
[2] Univ Minnesota, Dept Chem, Minneapolis, MN 55455 USA
基金
美国国家科学基金会;
关键词
Multivariate curve resolution; Alternating least squares; LC x LC; Comprehensive two dimensional liquid chromatography; Phase shifts; Rank deficiencies; PEAK-CAPACITY; METABOLOMICS; SEPARATIONS; DEPENDENCE; RESOLUTION; TIME; CELL;
D O I
10.1016/j.chroma.2011.09.057
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
There has been a tremendous increase in research on comprehensive two dimensional LC (LC x LC); however, to date, the central analytical issue, quantification, has received only minimal attention. It is vital to the further development of LC x LC that a greater understanding of the specific factors affecting peak quantification in LC x LC be attained. This work focuses on the following factors: data complexity, retention time shifting, dynamic range issues, chromatographic and spectral peak overlap and difficulties related to background signal removal. The above mentioned factors that affect peak quantification are investigated using fourteen replicate analyses of a urine sample, representing the effects of such factors when analyzing samples in complex matrices. We demonstrate that quantification of LC x LC data is improved following implementation of chemometric techniques that minimized the deleterious effects on quantification due to chromatographically overlapped peaks, retention time shifting and background signal interference. The chemometrically resolved data shows a 2.5-fold increase in precision of quantification over the quantification of the raw data. It is also demonstrated that the method quantifies sixteen peaks that were not visually evident prior to chemometric analysis. The purpose of this paper is to determine the impact of these issues on the effectiveness of LC x LC as a technique for the quantitative analysis of complex samples. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:8411 / 8422
页数:12
相关论文
共 50 条
  • [1] Chemometric analysis of comprehensive two-dimensional gas chromatography data using cryogenic modulation
    Xie, LL
    Marriott, PJ
    Adams, M
    ANALYTICA CHIMICA ACTA, 2003, 500 (1-2) : 211 - 222
  • [2] Semi-automated alignment and quantification of peaks using parallel factor analysis for comprehensive two-dimensional liquid chromatography-diode array detector data sets
    Allen, Robert C.
    Rutan, Sarah C.
    ANALYTICA CHIMICA ACTA, 2012, 723 : 7 - 17
  • [3] The chemometric resolution and quantification of overlapped peaks form comprehensive two-dimensional liquid chromatography
    Fraga, CG
    Corley, CA
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1096 (1-2) : 40 - 49
  • [4] Quantification in comprehensive two-dimensional liquid chromatography
    Mondello, Luigi
    Herrero, Miguel
    Kumm, Tiina
    Dugo, Paola
    Cortes, Hernan
    Dugo, Giovanni
    ANALYTICAL CHEMISTRY, 2008, 80 (14) : 5418 - 5424
  • [5] Quantification in Comprehensive Two-Dimensional Liquid Chromatography
    Reichenbach, Stephen E.
    ANALYTICAL CHEMISTRY, 2009, 81 (12) : 5099 - 5101
  • [6] Effect of background correction on peak detection and quantification in online comprehensive two-dimensional liquid chromatography using diode array detection
    Allen, Robert C.
    John, Mallory G.
    Rutan, Sarah C.
    Filgueira, Marcelo R.
    Carr, Peter W.
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1254 : 51 - 61
  • [7] Analysis of four-way two-dimensional liquid chromatography-diode array data: Application to metabolomics
    Porter, Sarah E. G.
    Stoll, Dwight R.
    Rutan, Sarah C.
    Carr, Peter W.
    Cohen, Jerry D.
    ANALYTICAL CHEMISTRY, 2006, 78 (15) : 5559 - 5569
  • [8] Data analysis programs for comprehensive two-dimensional chromatography
    Kallio, Minna
    Kivilompolo, Maarit
    Varjo, Sami
    Jussila, Matti
    Hyotylainen, Tuulia
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (14) : 2923 - 2927
  • [9] Investigation of interpolation techniques for the reconstruction of the first dimension of comprehensive two-dimensional liquid chromatography-diode array detector data
    Allen, Robert C.
    Rutan, Sarah C.
    ANALYTICA CHIMICA ACTA, 2011, 705 (1-2) : 253 - 260
  • [10] An untargeted lipidomic strategy combining comprehensive two-dimensional liquid chromatography and chemometric analysis
    Navarro-Reig, Meritxell
    Jaumot, Joaquim
    Tauler, Roma
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1568 : 80 - 90