β-Cyclodextrin functionalized mesoporous silica for electrochemical selective sensor: Simultaneous determination of nitrophenol isomers

被引:132
作者
Xu, Xiaomeng [1 ]
Liu, Zhen [1 ]
Zhang, Xin [1 ]
Duan, Shuo [1 ]
Xu, Shuai [1 ]
Zhou, Changli [1 ]
机构
[1] Univ Jinan, Sch Chem & Chem Engn, Jinan 250022, Peoples R China
基金
中国国家自然科学基金;
关键词
beta-Cyclodextrin functionalization; Hexagonal mesoporous silica; Nitrophenol isomers; Simultaneous determination; PERFORMANCE LIQUID-CHROMATOGRAPHY; POLYCYCLIC AROMATIC-HYDROCARBONS; STATIONARY-PHASE; ECE MECHANISM; SEPARATION; TOXICITY; PHENOL; WATER; REDUCTION; 4-NITROPHENOL;
D O I
10.1016/j.electacta.2011.09.015
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The beta-cyclodextrin functionalized SBA-15 was synthesized and employed for the fabrication of modified carbon paste electrodes. The electrochemical behavior of o-nitrophenol (o-NP), m-nitrophenol (m-NP) and p-nitrophenol (p-NP) was investigated at the modified electrode. Due to the inhibition of bonded cyclodextrin, the electrode reaction of nitrophenol was interrupted at hydroxylaminophenol stage, three nitrophenol isomers can be discriminated simultaneously according to the different potential of nitrosophenol/hydroxylaminophenol redox reaction. Therefore, low detection limits of 1.0 x 10(-8) mol L-1 for o-NP and p-NP, 5.0 x 10(-8) mol L-1 for m-NP were obtained, the linear ranges of the calibration curves are 2.0 x 10(-7) to 1.4 x 10(-6) mol L-1, 2.0 x 10(-7) to 1.6 x 10(-6) mol L-1 and 2.0 x 10(-7) to 1.4 x 10(-6) mol L-1, respectively. Consequently, a selective nitrophenol isomers electrochemical sensor was successfully fabricated and a sensitive method was developed for the determination of o-NP, m-NP and p-NP in aqueous solution simultaneously. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:142 / 149
页数:8
相关论文
共 68 条
[1]   ELECTROCHEMICAL STUDY OF KINETICS OF A CHEMICAL REACTION COUPLED BETWEEN 2 CHARGE TRANSFER REACTIONS - POTENTIOSTATIC REDUCTION OF P-NITROSOPHENOL [J].
ALBERTS, GS ;
SHAIN, I .
ANALYTICAL CHEMISTRY, 1963, 35 (12) :1859-&
[2]   A novel high selective and sensitive para-nitrophenol voltammetric sensor, based on a molecularly imprinted polymer-carbon paste electrode [J].
Alizadeh, Taher ;
Ganjali, Mohammad Reza ;
Norouzi, Parviz ;
Zare, Mashallah ;
Zeraatkar, Ali .
TALANTA, 2009, 79 (05) :1197-1203
[3]   SEPARATION OF DRUG STEREOISOMERS BY THE FORMATION OF BETA-CYCLODEXTRIN INCLUSION COMPLEXES [J].
ARMSTRONG, DW ;
WARD, TJ ;
ARMSTRONG, RD ;
BEESLEY, TE .
SCIENCE, 1986, 232 (4754) :1132-1135
[4]  
Bard A.J., 2001, Electrochemical Methods: Fundamentals and Applications, V2nd, P233
[5]   A CRITICAL-REVIEW OF THE LITERATURE ON NITROBENZENE TOXICITY [J].
BEAUCHAMP, RO ;
IRONS, RD ;
RICKERT, DE ;
COUCH, DB ;
HAMM, TE .
CRC CRITICAL REVIEWS IN TOXICOLOGY, 1982, 11 (01) :33-84
[6]  
Bender M.L., 1978, Cyclodextrin chemistry
[7]   Adsorption and separation of water-soluble aromatic molecules by cyclodextrin-functionalized mesoporous silica [J].
Bibby, A ;
Mercier, L .
GREEN CHEMISTRY, 2003, 5 (01) :15-19
[8]   A water-soluble tetraethylsulfonate derivative of 2-methylresorcinarene as an additive for capillary electrophoresis [J].
Britr-McKibbin, P ;
Chen, DDY .
ANALYTICAL CHEMISTRY, 1998, 70 (05) :907-912
[9]   Cyclodextrin-modified capillary electrophoresis: Determination of polycyclic aromatic hydrocarbons in contaminated soils [J].
Brown, RS ;
Luong, JHT ;
Szolar, OHJ ;
Halasz, A ;
Hawari, J .
ANALYTICAL CHEMISTRY, 1996, 68 (02) :287-292
[10]   The stability of cyclodextrin complexes in solution [J].
Connors, KA .
CHEMICAL REVIEWS, 1997, 97 (05) :1325-1357