Coronary Angiography After Transcatheter Aortic Valve Replacement ( TAVR) to Evaluate the Risk of Coronary Access Impairment After TAVR-in-TAVR

被引:68
作者
Nai Fovino, Luca [1 ]
Scotti, Andrea [1 ]
Massussi, Mauro [1 ]
Cardaioli, Francesco [1 ]
Rodino, Giulio [1 ]
Matsuda, Yuji [1 ]
Pavei, Andrea [1 ]
Masiero, Giulia [1 ]
Napodano, Massimo [1 ]
Fraccaro, Chiara [1 ]
Fabris, Tommaso [1 ]
Tarantini, Giuseppe [1 ]
机构
[1] Univ Padua, Dept Cardiac Thorac Vasc Sci & Publ Hlth, Sch Med, Padua, Italy
来源
JOURNAL OF THE AMERICAN HEART ASSOCIATION | 2020年 / 9卷 / 13期
关键词
coronary access; durability; structural valve degeneration; TAVR-in-TAVR; transcatheter aortic valve replacement; valve-in-valve; IMPLANTATION;
D O I
10.1161/JAHA.120.016446
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Transcatheter aortic valve replacement ( TAVR)--in--TAVR is a possible treatment for transcatheter heart valve ( THV) degeneration. However, the displaced leaflets of the first THV will create a risk plane (RP) under which the passage of a coronary catheter will be impossible. The aim of our study was to evaluate the potential risk of impaired coronary access (CA) after TAVR--in--TAVR. METHODS AND RESULTS: We prospectively performed coronary angiography after TAVR with different THVs in 137 consecutive patients, looking where the catheter crossed the valve frame. If coronary cannulation was achieved from below the RP, the distance between valve frame and aortic wall was measured by aortic angiography. CA after TAVR--in--TAVR was defined as feasible if the catheter passed above the RP, as theoretically feasible if passed under the RP with valve--to--aorta distance >2 mm, and as unfeasible if passed under the RP with valve--to--aorta distance =2 mm. Seventy--two patients (53%) received a Sapien 3 THV, 26 (19%) received an Evolut Pro/R THV, and 39 (28%) received an Acurate Neo THV. CA after TAVR--in--TAVR was considered feasible in 40.9% (68.1%, 19.2%, and 5.1%, respectively; P<0.001), theoretically feasible in 27.7% (8.3%, 42.3%, and 53.8%, respectively; P<0.001), and unfeasible in 31.4% (23.6%, 38.5%, and 41.1%, respectively; P=0.116). Independent predictors of impaired CA after TAVR--in--TAVR were female sex (odds ratio [OR], 3.99; 95% CI, 1.07-14.86; P=0.040), sinotubular junction diameter (OR, 0.62; 95% CI, 0.48- 0.80; P<0.001), and implantation of a supra--annular THV (OR, 6.61; 95% CI, 1.98-22.03; P= 0.002). CONCLUSIONS: CA after TAVR--in--TAVR might be unfeasible in >30% of patients currently treated with TAVR. Patients with a small sinotubular junction and those who received a supra--annular THV are at highest risk of potential CA impairment with TAVR--in--TAVR.
引用
收藏
页码:1 / 18
页数:18
相关论文
共 24 条
[1]   Coronary Access After Repeated Transcatheter Aortic Valve Implantation A Glimpse Into the Future [J].
Buzzatti, Nicola ;
Romano, Vittorio ;
De Backer, Ole ;
Soendergaard, Lars ;
Rosseel, Liesbeth ;
Maurovich-Horvat, Pal ;
Karady, Julia ;
Merkely, Bela ;
Ruggeri, Stefania ;
Prendergast, Bernard ;
De Bonis, Michele ;
Colombo, Antonio ;
Montorfano, Matteo ;
Latib, Azeem .
JACC-CARDIOVASCULAR IMAGING, 2020, 13 (02) :508-515
[2]   Transfemoral aortic valve implantation with new-generation devices: the repositionable Lotus vs. the balloon-expandable Edwards Sapien 3 valve [J].
Fovino, Luca Nai ;
Badawy, Mostafa R. A. ;
Fraccaro, Chiara ;
D'Onofrio, Augusto ;
Purita, Paola A. M. ;
Frigo, Anna C. ;
Tellaroli, Paola ;
Mauro, Agnifili ;
Tusa, Maurizio ;
Napodano, Massimo ;
Gerosa, Gino ;
Iliceto, Sabino ;
Bedogni, Francesco ;
AbdelRheim, Alaa E. R. ;
Tarantini, Giuseppe .
JOURNAL OF CARDIOVASCULAR MEDICINE, 2018, 19 (11) :655-663
[3]   Risk stratification and prognostic assessment by myocardial perfusion-gated SPECT in patients with left bundle-branch block and low-intermediate cardiac risk [J].
Fovino, Luca Nai ;
Saladini, Giorgio ;
Mormino, Gino Paolo ;
Saladini, Francesca ;
Razzolini, Renato ;
Evangelista, Laura .
ANNALS OF NUCLEAR MEDICINE, 2012, 26 (07) :559-570
[4]  
Harrell FE, 1996, STAT MED, V15, P361, DOI 10.1002/(SICI)1097-0258(19960229)15:4<361::AID-SIM168>3.0.CO
[5]  
2-4
[6]   Minimizing Permanent Pacemaker Following Repositionable Self-Expanding Transcatheter Aortic Valve Replacement [J].
Jilaihawi, Hasan ;
Zhao, Zhengang ;
Du, Run ;
Staniloae, Cezar ;
Saric, Muhamed ;
Neuburger, Peter J. ;
Querijero, Michael ;
Vainrib, Alan ;
Hisamoto, Kazuhiro ;
Ibrahim, Homam ;
Collins, Tara ;
Clark, Emily ;
Pushkar, Illya ;
Bamira, Daniel ;
Benenstein, Ricardo ;
Tariq, Afnan ;
Williams, Mathew .
JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (18) :1796-1807
[7]  
Kappetein AP, 2012, J AM COLL CARDIOL, V60, P1438, DOI [10.1016/j.jacc.2012.09.001, 10.1093/ejcts/ezs533]
[8]   Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients [J].
Mack, M. J. ;
Leon, M. B. ;
Thourani, V. H. ;
Makkar, R. ;
Kodali, S. K. ;
Russo, M. ;
Kapadia, S. R. ;
Malaisrie, S. C. ;
Cohen, D. J. ;
Pibarot, P. ;
Leipsic, J. ;
Hahn, R. T. ;
Blanke, P. ;
Williams, M. R. ;
McCabe, J. M. ;
Brown, D. L. ;
Babaliaros, V. ;
Goldman, S. ;
Szeto, W. Y. ;
Genereux, P. ;
Pershad, A. ;
Pocock, S. J. ;
Alu, M. C. ;
Webb, J. G. ;
Smith, C. R. .
NEW ENGLAND JOURNAL OF MEDICINE, 2019, 380 (18) :1695-1705
[9]   Transcatheter Aortic-Valve Replacement-10 Years Later [J].
Murdoch, Dale J. ;
Webb, John G. ;
Ye, Jian ;
Sathananthan, Janarthanan ;
Hensey, Mark ;
Wood, David A. ;
Cheung, Anson ;
Leipsic, Jonathon ;
Blanke, Philipp ;
Lauck, Sandra .
NEW ENGLAND JOURNAL OF MEDICINE, 2019, 380 (18) :1773-1774
[10]   Impact of Right Ventricular Pacing in Patients Who Underwent Implantation of Permanent Pacemaker After Transcatheter Aortic Valve Implantation [J].
Nadeem, Fand ;
Tsushima, Takahiro ;
Ladas, Thomas P. ;
Thomas, Rahul B. ;
Patel, Sandeep M. ;
Saric, Petar ;
Patel, Toral ;
Lipinski, Jerry ;
Li, Jun ;
Costa, Marco A. ;
Simon, Daniel, I ;
Kalra, Ankur ;
Attizzani, Guillherme F. ;
Arruda, Mauricio S. ;
Mackall, Judith ;
Thal, Sergio G. .
AMERICAN JOURNAL OF CARDIOLOGY, 2018, 122 (10) :1712-1717