Diagnostic Value of Prospective Electrocardiogram-triggered Dual-source Computed Tomography Angiography for Infants and Children with Interrupted Aortic Arch

被引:1
作者
Li, Hai-Ou [1 ]
Wang, Xi-Ming [1 ]
Nie, Pei [2 ]
Ji, Xiao-Peng [1 ]
Cheng, Zhao-Ping [1 ]
Chen, Jiu-Hong [3 ]
Xu, Zhuo-Dong [1 ]
机构
[1] Shandong Univ, Shandong Med Imaging Res Inst, Dept CT, Jinan 250021, Shandong, Peoples R China
[2] Qingdao Univ, Affiliated Hosp, Dept Radiol, Qingdao 266071, Peoples R China
[3] Siemens Ltd, Siemens Healthcare, Dept CT Res Collaborat, Beijing 100102, Peoples R China
关键词
Dual-source Computed Tomography; Image Quality; Interrupted Aortic Arch; Prospective ECG-triggered; Radiation Dose; CONGENITAL HEART-DISEASE; BIRTH-WEIGHT INFANTS; MULTIDETECTOR CT; IMAGE QUALITY; CATHETERIZATION; RECONSTRUCTION;
D O I
10.4103/0366-6999.156109
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Accurate assessment of intra- as well as extra-cardiac malformations and radiation dosage concerns are especially crucial to infants and children with interrupted aortic arch (IAA). The purpose of this study is to investigate the value of prospective electrocardiogram (ECG)-triggered dual-source computed tomography (DSCT) angiography with low-dosage techniques in the diagnosis of IAA. Methods: Thirteen patients with suspected IAA underwent prospective ECG-triggered DSCT scan and transthoracic echocardiography (TTE). Surgery was performed on all the patients. A five-point scale was used to assess image quality. The diagnostic accuracy of DSCT angiography and TTE was compared with the surgical findings as the reference standard. A nonparametric Chi-square test was used for comparative analysis. P < 0.05 was considered as a significant difference. The mean effective radiation dose (ED) was calculated. Results: Diagnostic DSCT images were obtained for all the patients. Thirteen IAA cases with 60 separate cardiovascular anomalies were confirmed by surgical findings. The diagnostic accuracy of TTE and DSCT for total cardiovascular malformations was 93.7% and 97.9% (P > 0.05), and that for extra-cardiac vascular malformations was 92.3% and 99.0% (P < 0.05), respectively. The mean score of image quality was 3.77 0.83. The mean ED was 0.30 0.04 mSv (range from 0.23 mSv to 0.39 mSv). Conclusions: In infants and children with IAA, prospective ECG-triggered DSCT with low radiation exposure and high diagnostic efficiency has higher accuracy compared to TTE in detection of extra-cardiac vascular anomalies.
引用
收藏
页码:1184 / 1189
页数:6
相关论文
共 29 条
  • [1] Cumulative patient effective dose and acute radiation-induced chromosomal DNA damage in children with congenital heart disease
    Ait-Ali, Lamia
    Andreassi, Maria Grazia
    Foffa, Ilenia
    Spadoni, Isabella
    Vano, Eliseo
    Picano, Eugenio
    [J]. HEART, 2010, 96 (04) : 269 - 274
  • [2] Evaluation of image quality and radiation dose of thoracic and coronary dual-source CT in 110 infants with congenital heart disease
    Ben Saad, Moez
    Rohnean, Adela
    Sigal-Cinqualbre, Anne
    Adler, Ghazal
    Paul, Jean-Francois
    [J]. PEDIATRIC RADIOLOGY, 2009, 39 (07) : 668 - 676
  • [3] Current concepts - Computed tomography - An increasing source of radiation exposure
    Brenner, David J.
    Hall, Eric J.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) : 2277 - 2284
  • [4] CONGENITAL ABSENCE OF THE AORTIC ARCH
    CELORIA, GC
    PATTON, RB
    [J]. AMERICAN HEART JOURNAL, 1959, 58 (03) : 407 - 413
  • [5] Interrupted aortic arch in a neonate: multidetector CT diagnosis
    Cinar, A
    Haliloglu, M
    Karagoz, T
    Karcaaltincaba, M
    Celiker, A
    Tekinalp, G
    [J]. PEDIATRIC RADIOLOGY, 2004, 34 (11) : 901 - 903
  • [6] Earls James P, 2009, J Cardiovasc Comput Tomogr, V3, P45, DOI 10.1016/j.jcct.2008.10.013
  • [7] Three-tesla cardiac magnetic resonance imaging for preterm infants
    Foran, Adrienne M.
    Fitzpatrick, Julie A.
    Allsop, Joanna
    Schmitz, Stephan
    Franklin, Jamie
    Pamboucas, Constandinos
    O'Regan, Declan
    Hajnal, Jo V.
    Edwards, A. David
    [J]. PEDIATRICS, 2007, 120 (01) : 78 - 83
  • [8] Marked Reduction of Effective Radiation Dose in Patients Undergoing CT Coronary Angiography using Prospective ECG Gating
    Freeman, Anthony
    Learner, Ruth
    Eggleton, Simon
    Lambros, John
    Friedman, Daniel
    [J]. HEART LUNG AND CIRCULATION, 2011, 20 (08) : 512 - 516
  • [9] COMPLETE INTERRUPTION OF AORTA AT ARCH
    GOKCEBAY, TM
    BATILLAS, J
    PINCK, RL
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1972, 114 (02) : 362 - &
  • [10] Evaluation of image quality and radiation dose at prospective ECG-triggered axial 256-slice multi-detector CT in infants with congenital heart disease
    Huang, Mei-ping
    Liang, Chang-hong
    Zhao, Zhen-jun
    Liu, Hui
    Li, Jing-lei
    Zhang, Jin-e
    Cui, Yan-hai
    Yang, Lin
    Liu, Qi-shun
    Ivanc, Thomas B.
    Vembar, Mani
    [J]. PEDIATRIC RADIOLOGY, 2011, 41 (07) : 858 - 866