Background suppression in arterial spin labeling MRI with a separate neck labeling coil

被引:11
作者
Shen, Qiang [1 ,2 ,3 ]
Duong, Timothy Q. [1 ,2 ,3 ,4 ,5 ]
机构
[1] Univ Texas Hlth Sci Ctr San Antonio, Res Imaging Inst, San Antonio, TX 78229 USA
[2] Univ Texas Hlth Sci Ctr San Antonio, Dept Ophthalmol, San Antonio, TX 78229 USA
[3] Univ Texas Hlth Sci Ctr San Antonio, Dept Radiol, San Antonio, TX 78229 USA
[4] Univ Texas Hlth Sci Ctr San Antonio, Dept Physiol, San Antonio, TX 78229 USA
[5] Dept Vet Affairs, S Texas Vet Hlth Care Syst, San Antonio, TX USA
关键词
arterial spin labeling; rodents; cerebral blood flow; cerebral perfusion; high fields; inversion recovery; CEREBRAL-BLOOD-FLOW; TRANSIT-TIME; RAT-BRAIN; TISSUE WATER; PERFUSION; DIFFUSION; INVERSION; ISCHEMIA; EXCHANGE; SIGNAL;
D O I
10.1002/nbm.1666
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In arterial spin labeling (ASL) MRI to measure cerebral blood flow (CBF), pair-wise subtraction of temporally adjacent non-labeled and labeled images often can not completely cancel the background static tissue signal because of temporally fluctuating physiological noise. While background suppression (BS) by inversion nulling improves CBF temporal stability, imperfect pulses compromise CBF contrast. Conventional BS techniques may not be applicable in small animals because the arterial transit time is short. This study presents a novel approach of BS to overcome these drawbacks using a separate 'neck' radiofrequency coil for ASL and a 'brain' radiofrequency coil for BS with the inversion pulse placed before spin labeling. The use of a separate 'neck' coil for ASL should also improve ASL contrast. This approach is referred to as the inversion-recovery BS with the two-coil continuous ASL (IR-cASL) technique. The temporal and spatial contrast-to-noise characteristics of basal CBF and CBF-based fMRI of hypercapnia and forepaw stimulation in rats at 7 Tesla were analyzed. IR-cASL yielded two times better temporal stability and 2.0-2.3 times higher functional contrast-to-noise ratios for hypercapnia and forepaw stimulation compared with cASL without BS in the same animals. The Bloch equations were modified to provide accurate CBF quantification at different levels of BS and for multislice acquisition where different slices have different degree of BS and residual degree of labeling. Improved basal CBF and CBF-based fMRI sensitivity should lead to more accurate CBF quantification and should prove useful for imaging low CBF conditions such as in white matter and stroke. Copyright (C) 2011 John Wiley & Sons, Ltd.
引用
收藏
页码:1111 / 1118
页数:8
相关论文
共 37 条
[1]   Focal brain ischemia in rat:: acute changes in brain tissue T1 reflect acute increase in brain tissue water content [J].
Barbier, EL ;
Liu, LJ ;
Grillon, E ;
Payen, JF ;
Lebas, JF ;
Segebarth, C ;
Rémy, C .
NMR IN BIOMEDICINE, 2005, 18 (08) :499-506
[2]   Methodology of brain perfusion imaging [J].
Barbier, EL ;
Lamalle, L ;
Décorps, M .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (04) :496-520
[3]   Selective arterial spin Labeling (SASL): Perfusion territory mapping of selected feeding arteries tagged using two-dimensional radiofrequency pulses [J].
Davies, NP ;
Jezzard, P .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (06) :1133-1142
[4]   MULTIPLE INVERSION RECOVERY REDUCES STATIC TISSUE SIGNAL IN ANGIOGRAMS [J].
DIXON, WT ;
SARDASHTI, M ;
CASTILLO, M ;
STOMP, GP .
MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) :257-268
[5]   Localized cerebral blood flow response at submillimeter columnar resolution [J].
Duong, TQ ;
Kim, DS ;
Ugurbil, K ;
Kim, SG .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2001, 98 (19) :10904-10909
[6]   High-sensitivity single-shot perfusion-weighted fMRI [J].
Duyn, JH ;
Tan, CX ;
van Gelderen, P ;
Yongbi, MN .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (01) :88-94
[7]   Modeling and optimization of Look-Locker spin labeling for measuring perfusion and transit time changes in activation studies taking into account arterial blood volume [J].
Francis, S. T. ;
Bowtell, R. ;
Gowland, P. A. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (02) :316-325
[8]   Efficiency of inversion pulses for background suppressed arterial spin labeling [J].
Garcia, DM ;
Duhamel, G ;
Alsop, DC .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (02) :366-372
[9]   WHAT IS THE CORRECT VALUE FOR THE BRAIN BLOOD PARTITION-COEFFICIENT FOR WATER [J].
HERSCOVITCH, P ;
RAICHLE, ME .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1985, 5 (01) :65-69
[10]   Blood-flow magnetic resonance imaging of the retina [J].
Li, Yingxia ;
Cheng, Haiying ;
Duong, Timothy Q. .
NEUROIMAGE, 2008, 39 (04) :1744-1751