A new, highly sensitive time-of-flight mass spectrometer consisting of a flangeon-type conical ion lens system and a proto-type daly detector for exhaust gas analysis based on the Jet-REMPI technique

被引:20
作者
Suzuki, T [1 ]
Hayashi, S
Ishiuchi, S
Saeki, M
Fujii, M
机构
[1] Tohoku Univ, Grad Sch Environm Studies, Sendai, Miyagi 9808579, Japan
[2] Nippon Steel Techno Res Corp, Chiba 2930011, Japan
[3] Nippon Steel Corp Ltd, Chiba 2938511, Japan
[4] Tokyo Inst Technol, Chem Resources Lab, Yokohama, Kanagawa 2268503, Japan
[5] Japan Atom Energy Res Inst, Tokai, Ibaraki 3191195, Japan
关键词
D O I
10.2116/analsci.21.991
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
For the analysis of trace amounts of hazardous organic compounds, we developed a new ion detection system for supersonic jet resonance-enhanced multiphoton laser ionization mass spectrometry. High sensitivity and selectivity have been achieved by combining a proto-type Daly detector, a newly designed conical ion lens, and a potential switch that can perform the function of a mass selector. This ion detection system enables us to bring the jet nozzle closer to the ionization point. The detection sensitivity has thus been improved totally by more than 100 times compared with that obtained by the parallel-plate electrodes and micro-channel plate. We succeeded in assembling a flangeon-type ion extraction electrode consisting of a conical ion lens and a potential switch.
引用
收藏
页码:991 / 996
页数:6
相关论文
共 23 条
  • [11] Scheme for collinear ionization in supersonic jet/multiphoton ionization/time-of-flight mass spectrometry
    Onoda, T
    Saito, G
    Imasaka, T
    [J]. ANALYTICA CHIMICA ACTA, 2000, 412 (1-2) : 213 - 219
  • [12] Congener-specific detection of dioxins using jet-REMPI
    Oser, H
    Copic, K
    Coggiola, MJ
    Faris, GW
    Crosley, DR
    [J]. CHEMOSPHERE, 2001, 43 (4-7) : 469 - 477
  • [13] Continuous monitoring of ultratrace products of incomplete combustion during incineration with a novel mobile Jet-REMPI device
    Oser, H
    Thanner, R
    Grotheer, HH
    [J]. CHEMOSPHERE, 1998, 37 (9-12) : 2361 - 2374
  • [14] TRANSFORMATION BETWEEN CARTESIAN AND SPHERICAL TENSORS
    STONE, AJ
    [J]. MOLECULAR PHYSICS, 1975, 29 (05) : 1461 - 1471
  • [15] STONE AJ, 1976, J PHYS, V9, P1461
  • [16] Selective detection of dibenzodioxin, dibenzofuran and some small polycyclic aromatics
    Velazquez, J
    Voloboueva, LA
    Cool, TA
    [J]. COMBUSTION SCIENCE AND TECHNOLOGY, 1998, 134 (1-6) : 139 - 163
  • [17] LASER MASS-SPECTROMETRY OF THE DICHLOROBENZENES, TRICHLOROBENZENES AND TETRACHLOROBENZENES - ISOMER-SELECTIVE IONIZATION AND DETECTION
    WEICKHARDT, C
    ZIMMERMANN, R
    SCHRAMM, KW
    BOESL, U
    SCHLAG, EW
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (05) : 381 - 384
  • [18] WEIKHARDT C, 1993, RAPID COMMUN MASS SP, V7, P183
  • [19] ISOMER-SELECTIVE IONIZATION OF CHLORINATED AROMATICS WITH LASERS FOR ANALYTICAL TIME-OF-FLIGHT MASS-SPECTROMETRY - FIRST RESULTS FOR POLYCHLORINATED DIBENZO-P-DIOXINS (PCDD), BIPHENYLS (PCB) AND BENZENES (PCBZ)
    ZIMMERMANN, R
    BOESL, U
    WEICKHARDT, C
    LENOIR, D
    SCHRAMM, KW
    KETTRUP, A
    SCHLAG, EW
    [J]. CHEMOSPHERE, 1994, 29 (9-11) : 1877 - 1888
  • [20] Zimmermann R, 1999, RAPID COMMUN MASS SP, V13, P307, DOI 10.1002/(SICI)1097-0231(19990315)13:5<307::AID-RCM482>3.0.CO