Evaluation of a magnetic polysulfone microcapsule containing organic modified montmorillonite as a novel solid-phase extraction sorbent with chlorophenols as model compounds

被引:56
作者
Liu, Xiaoyan [1 ]
Yin, Juanjuan [1 ]
Zhu, Ling [1 ]
Zhao, Guanghui [1 ]
Zhang, Haixia [1 ,2 ]
机构
[1] Lanzhou Univ, State Key Lab Appl Organ Chem, Lanzhou 730000, Peoples R China
[2] Lanzhou Univ, Key Lab Nonferrous Met Chem & Resources Utilizat, Lanzhou 730000, Peoples R China
关键词
Magnetic solid-phase extraction; Organic modified montmorillonite; Polysulfone; Chlorophenols; PERFORMANCE LIQUID-CHROMATOGRAPHY; MOLECULARLY IMPRINTED POLYMER; MULTIWALLED CARBON NANOTUBES; DETERMINE PHENOLIC-COMPOUNDS; WATER; MICROEXTRACTION; ONLINE; PRECONCENTRATION; ENRICHMENT; ADSORBENT;
D O I
10.1016/j.talanta.2011.07.106
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A porous polysulfone microcapsule containing organic modified montmorillonite and magnetic nanoparticles (OMMT-Fe3O4@PSF) has been successfully prepared by a phase-inversion method and evaluated as a magnetic solid-phase extraction (MSPE) sorbent for clean-up and enrichment of 4-chlorophenol (4-CP) and 2-chlorophenol (2-CP) in aqueous samples. Compared with a microcapsule containing the conventional extraction sorbent C18 (C18-Fe3O4@PSF), OMMT-Fe3O4@PSF had much lower cost, a faster adsorption rate, and superior uptake amounts for the investigated analytes. The proposed microcapsule has been developed for the extraction of 4-CP and 2-CP from environmental water samples and their analysis by high-performance liquid chromatography with UV detection (HPLC-UV). Various parameters, such as pH, extraction time, the mass of sorbent, and the desorption conditions, have been evaluated and the calibration curves of the chlorophenols were linear (R-2 >= 0.9985) in the range from 1.01 to 104.5 ng mL(-1). The limits of detection at a signal-to-noise (S/N) ratio of 3 were 0.22 and 0.17 ng mL(-1) and the limits of quantification calculated at S/N =10 were 1.52 and 1.07 ng mL(-1) for 2-CP and 4-CP, respectively. The recoveries of 2-CP and 4-CP from natural water and the treated wastewater samples were in the range of 84.4-115% with relative standard deviations (RSDs) lower than 7.0%. The results have demonstrated the suitability of the MSPE approach for the analysis of trace chlorophenols in aqueous samples. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:2451 / 2457
页数:7
相关论文
共 45 条
[1]   Alumina physically loaded by thiosemicarbazide for selective preconcentration of mercury(II) ion from natural water samples [J].
Ahmed, Salwa A. .
JOURNAL OF HAZARDOUS MATERIALS, 2008, 156 (1-3) :521-529
[2]   An electropolymerized aniline-based fiber coating for solid phase microextraction of phenols from water [J].
Bagheri, H ;
Mir, A ;
Babanezhad, E .
ANALYTICA CHIMICA ACTA, 2005, 532 (01) :89-95
[3]   On-line trace enrichment of phenolic compounds from water using a pyrrole-based polymer as the solid-phase extraction sorbent coupled with high-performance liquid chromatography [J].
Bagheri, H ;
Mohammadi, A ;
Salemi, A .
ANALYTICA CHIMICA ACTA, 2004, 513 (02) :445-449
[4]   Determination of phenols using simultaneous steam distillation-extraction [J].
Barták, P ;
Frnková, P ;
Cáp, L .
JOURNAL OF CHROMATOGRAPHY A, 2000, 867 (1-2) :281-287
[5]   On-line solid-phase extraction of triazine herbicides using a molecularly imprinted polymer for selective sample enrichment [J].
Bjarnason, B ;
Chimuka, L ;
Ramström, O .
ANALYTICAL CHEMISTRY, 1999, 71 (11) :2152-2156
[6]   Multiwalled carbon nanotubes as a solid-phase extraction adsorbent for the determination of bisphenol a, 4-n-nonylphenol, and 4-tert-octylphenol [J].
Cai, YQ ;
Jiang, GB ;
Liu, JF ;
Zhou, QX .
ANALYTICAL CHEMISTRY, 2003, 75 (10) :2517-2521
[7]   Analysis of pesticide residues in matrices with high lipid contents by membrane separation coupled on-line to a high-performance liquid chromatography system [J].
Carabias-Martínez, R ;
Rodríguez-Gonzalo, E ;
Paniagua-Marcos, PH ;
Hernández-Méndez, J .
JOURNAL OF CHROMATOGRAPHY A, 2000, 869 (1-2) :427-439
[8]  
Díaz TG, 1999, ANAL CHIM ACTA, V384, P185, DOI 10.1016/S0003-2670(98)00829-0
[9]   Molecularly imprinted solid-phase extraction combined with high performance liquid chromatography for analysis of phenolic compounds from environmental water samples [J].
Feng, Qin-Zhong ;
Zhao, Li-Xia ;
Yan, Wei ;
Lin, Jin-Ming ;
Zheng, Zhi-Xia .
JOURNAL OF HAZARDOUS MATERIALS, 2009, 167 (1-3) :282-288
[10]   Molecularly imprinted polymer as micro-solid phase extraction combined with high performance liquid chromatography to determine phenolic compounds in environmental water samples [J].
Feng, Qinzhong ;
Zhao, Lixia ;
Lin, Jin-Ming .