Near-infrared spectroscopic analysis of the breaking force of extended-release matrix tablets prepared by roller-compaction: influence of plasticizer levels and sintering temperature

被引:12
作者
Dave, Vivek S. [1 ]
Fahmy, Raafat M. [2 ]
Hoag, Stephen W. [3 ]
机构
[1] St John Fisher Coll, Wegmans Sch Pharm, Rochester, NY 14618 USA
[2] US FDA, Rockville, MD USA
[3] Univ Maryland, Sch Pharm, Dept Pharmaceut Sci, Baltimore, MD 21201 USA
关键词
Matrix tablets; near-infrared; plasticizer; roller compaction; sintering temperature; DIFFUSE-REFLECTANCE SPECTROSCOPY; ANALYTICAL TECHNOLOGY APPROACH; DRIED INJECTION PRODUCT; HARD GELATIN CAPSULES; FILM COATING PROCESS; NONDESTRUCTIVE METHOD; MOISTURE-CONTENT; CONTENT UNIFORMITY; BLEND HOMOGENEITY; NIR SPECTROSCOPY;
D O I
10.3109/03639045.2014.911883
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
The aim of this study was to investigate the feasibility of near-infrared (NIR) spectroscopy for the determination of the influence of sintering temperature and plasticizer levels on the breaking force of extended-release matrix tablets prepared via roller-compaction. Six formulations using theophylline as a model drug, Eudragit (R) RL PO or Eudragit (R) RS PO as a matrix former and three levels of TEC (triethyl citrate) as a plasticizer were prepared. The powder blend was roller compacted using a fixed roll-gap of 1.5 mm, feed screw speed to roller speed ratio of 5: 1 and roll pressure of 4 MPa. The granules, after removing fines, were compacted into tablets on a Stokes B2 rotary tablet press at a compression force of 7 kN. The tablets were thermally treated at different temperatures (Room Temperature, 50, 75 and 100 degrees C) for 5 h. These tablets were scanned in reflectance mode in the wavelength range of 400-2500 nm and were evaluated for breaking force. Tablet breaking force significantly increased with increasing plasticizer levels and with increases in the sintering temperature. An increase in tablet hardness produced an upward shift (increase in absorbance) in the NIR spectra. The principle component analysis (PCA) of the spectra was able to distinguish samples with different plasticizer levels and sintering temperatures. In addition, a 9-factor partial least squares (PLS) regression model for tablets containing Eudragit (R) RL PO had an r(2) of 0.9797, a standard error of calibration of 0.6255 and a standard error of cross validation (SECV) of 0.7594. Similar analysis of tablets containing Eudragit (R) RS PO showed an r(2) of 0.9831, a standard error of calibration of 0.9711 and an SECV of 1.192.
引用
收藏
页码:898 / 905
页数:8
相关论文
共 66 条
[1]   Quantitative analysis of film coating in a fluidized bed process by in line NIR spectrometry and multivariate batch calibration [J].
Andersson, M ;
Folestad, S ;
Gottfries, J ;
Johansson, MO ;
Josefson, M ;
Wahlund, KG .
ANALYTICAL CHEMISTRY, 2000, 72 (09) :2099-2108
[2]   Monitoring of a film coating process for tablets using near infrared reflectance spectrometry [J].
Andersson, M ;
Josefson, M ;
Langkilde, FW ;
Wahlund, KG .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 20 (1-2) :27-37
[3]   Real-time monitoring of powder mixing in a convective blender using non-invasive reflectance NIR spectrometry [J].
Bellamy, Luke J. ;
Nordon, Alison ;
Littlejohn, David .
ANALYST, 2008, 133 (01) :58-64
[4]   Quantitative in-line monitoring of powder blending by near infrared reflection spectroscopy [J].
Berntsson, O ;
Danielsson, LG ;
Lagerholm, B ;
Folestad, S .
POWDER TECHNOLOGY, 2002, 123 (2-3) :185-193
[5]   Determination of moisture in hard gelatin capsules using near-infrared spectroscopy: Applications to at-line process control of pharmaceutics [J].
Berntsson, O ;
Zackrisson, G ;
Ostling, G .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 15 (07) :895-900
[6]   Diclofenac release from Eudragit-containing matrices and effects of thermal treatment [J].
Billa, N ;
Yuen, KH ;
Peh, KK .
DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 1998, 24 (01) :45-50
[7]   Content uniformity and tablet hardness testing of intact pharmaceutical tablets by near infrared spectroscopy -: A contribution to process analytical technologies [J].
Blanco, M ;
Alcalá, M .
ANALYTICA CHIMICA ACTA, 2006, 557 (1-2) :353-359
[8]   A process analytical technology approach based on near infrared spectroscopy:: Tablet hardness, content uniformity, and dissolution test measurements of intact tablets [J].
Blanco, Marcelo ;
Alcala, Manel ;
Gonzalez, Josep M. ;
Torrasz, Ester .
JOURNAL OF PHARMACEUTICAL SCIENCES, 2006, 95 (10) :2137-2144
[9]   Diffuse reflectance near-infrared spectroscopy as a nondestructive analytical technique for polymer implants [J].
Brashear, RL ;
Flanagan, DR ;
Luner, PE ;
Seyer, JJ ;
Kemper, MS .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1999, 88 (12) :1348-1353
[10]   Use of near-infrared spectroscopy to evaluate an active in a film coated tablet [J].
Buchanan, BR ;
Baxter, MA ;
Chen, TS ;
Qin, XZ ;
Robinson, PA .
PHARMACEUTICAL RESEARCH, 1996, 13 (04) :616-621