Use of CO2 balances to determine ventilation rates in a fattening rabbit house

被引:1
|
作者
Estelles, F. [1 ]
Fernandez, N. [1 ]
Torres, A. G. [1 ]
Calvet, S. [1 ]
机构
[1] Univ Politecn Valencia, Inst Anim Sci & Technol, Valencia 46022, Spain
关键词
accuracy; animal welfare; climatization; emissions; LIVESTOCK BUILDINGS; CARBON-DIOXIDE; EMISSION; AMMONIA; FLOW;
D O I
暂无
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
Determining accurately the ventilation rates from rabbits houses, using non-expensive and non-invasive methods, is needed. The main aim of this work was to test the carbon dioxide balance as a method to determine the ventilation rate in fattening rabbit farms. In addition, the CO2 release rate from rabbit manure was measured, and the effect of CO2 concentration gradient between the inlet and outlet air of the building, on the method accuracy was characterized. To these aims, a fattening rabbit farm was evaluated during two periods and CO2 concentrations were simultaneously monitored in the inlet and outlet air by using a photoacoustic monitor. Ventilation rates were also directly determined by calibration of the exhaust fans and monitoring their operation times. CO2 emissions from manure were measured during two whole fattening periods, using a flux chamber and a photoacoustic monitor. The effect of CO2 concentrations gradient between the inlet and outlet of the farm on the accuracy of the balance was studied through statistical regressions. The CO2 emission from manure resulted in 13% of total CO2 emissions (considering both manure and animals). No statistically significant differences were found between measured and calculated ventilation rates. The effect of the CO2 gradient on the balance accuracy was statistically significant only in one of the trials. According to these results, the CO2 balance can be recommended for the determination of ventilation rates in fattening rabbit buildings.
引用
收藏
页码:713 / 720
页数:8
相关论文
共 50 条
  • [21] Association of ventilation rates and CO2 concentrations with health and other responses in commercial and institutional buildings
    Helsinki University of Technology, Laboratory for Heating, Ventilating and Air Conditioning, Helsinki, Finland
    Indoor Air, 4 (226-252):
  • [22] Association of ventilation rates and CO2 concentrations with health and other responses in commercial and institutional buildings
    Seppänen, OA
    Fisk, WJ
    Mendell, MJ
    INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1999, 9 (04): : 226 - 252
  • [23] A Simple Method to Determine the Timing of Snow Melt by Remote Sensing with Application to the CO2 Balances of Northern Mire and Heath Ecosystems
    Rinne, Janne
    Aurela, Mika
    Manninen, Terhikki
    REMOTE SENSING, 2009, 1 (04): : 1097 - 1107
  • [24] STABILITY ANALYSIS OF CO2 CONTROL OF VENTILATION
    ELHEFNAWY, A
    SAIDEL, GM
    BRUCE, EN
    CHERNIACK, NS
    JOURNAL OF APPLIED PHYSIOLOGY, 1990, 69 (02) : 498 - 503
  • [26] THE DIVERGENCE OF EXERCISE VENTILATION AND CO2 RESPONSIVENESS
    MENITOVE, SM
    RAPOPORT, DM
    EPSTEIN, H
    SORKIN, B
    GOLDRING, RM
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1982, 125 (04): : 210 - 210
  • [27] Ventilation and anthropogenic CO2 in the Sulu Sea
    Huang, Peng
    Tanhua, Toste
    JOURNAL OF MARINE SYSTEMS, 2017, 170 : 1 - 9
  • [28] Demand control ventilation using CO2
    Schell, M
    Int-Hout, D
    ASHRAE JOURNAL, 2001, 43 (02) : 18 - +
  • [29] NEONATAL MECHANICAL VENTILATION AND EXPIRED CO2
    STOTHERS, JK
    CAMPBELL, CA
    MUKHTAR, AI
    ARCHIVES OF DISEASE IN CHILDHOOD, 1980, 55 (12) : 970 - 970
  • [30] Rethinking Alveolar Ventilation and CO2 Removal
    Cove, Matthew E.
    Pinsky, Michael R.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2021, 203 (03) : 277 - 278