Use of CO2 balances to determine ventilation rates in a fattening rabbit house

被引:1
|
作者
Estelles, F. [1 ]
Fernandez, N. [1 ]
Torres, A. G. [1 ]
Calvet, S. [1 ]
机构
[1] Univ Politecn Valencia, Inst Anim Sci & Technol, Valencia 46022, Spain
关键词
accuracy; animal welfare; climatization; emissions; LIVESTOCK BUILDINGS; CARBON-DIOXIDE; EMISSION; AMMONIA; FLOW;
D O I
暂无
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
Determining accurately the ventilation rates from rabbits houses, using non-expensive and non-invasive methods, is needed. The main aim of this work was to test the carbon dioxide balance as a method to determine the ventilation rate in fattening rabbit farms. In addition, the CO2 release rate from rabbit manure was measured, and the effect of CO2 concentration gradient between the inlet and outlet air of the building, on the method accuracy was characterized. To these aims, a fattening rabbit farm was evaluated during two periods and CO2 concentrations were simultaneously monitored in the inlet and outlet air by using a photoacoustic monitor. Ventilation rates were also directly determined by calibration of the exhaust fans and monitoring their operation times. CO2 emissions from manure were measured during two whole fattening periods, using a flux chamber and a photoacoustic monitor. The effect of CO2 concentrations gradient between the inlet and outlet of the farm on the accuracy of the balance was studied through statistical regressions. The CO2 emission from manure resulted in 13% of total CO2 emissions (considering both manure and animals). No statistically significant differences were found between measured and calculated ventilation rates. The effect of the CO2 gradient on the balance accuracy was statistically significant only in one of the trials. According to these results, the CO2 balance can be recommended for the determination of ventilation rates in fattening rabbit buildings.
引用
收藏
页码:713 / 720
页数:8
相关论文
共 50 条
  • [1] Checking of ventilation rates by CO2 monitoring
    Ekberg, LE
    Strindehag, O
    17TH AIVC CONFERENCE - OPTIMUM VENTILATION AND AIR FLOW CONTROL IN BUILDING, PROCEEDINGS, VOLS 1 AND 2, 1996, : 75 - 85
  • [2] Volumetric CO2 monitoring to determine successful liberation from mechanical ventilation
    Hekier, E.
    Scott, G.
    Newhart, J.
    Emerick, J.
    Chiles, P.
    Morris, T.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2008, 56 (01) : 239 - 240
  • [3] Ventilation Rates and Unsatisfied Percentage from Indoor CO2 Concentration
    Costanzo, S.
    Cusumano, A.
    Giaconia, C.
    INDOOR AND BUILT ENVIRONMENT, 2011, 20 (02) : 232 - 245
  • [4] ESTIMATING VENTILATION RATES OF ANIMAL HOUSES THROUGH CO2 BALANCE
    Liu, Z.
    Powers, W.
    Harmon, J. D.
    TRANSACTIONS OF THE ASABE, 2016, 59 (01) : 321 - 328
  • [5] The use of forced ventilation during microlaryngoscopy with laser CO2
    Marco de Vincentiis
    Massimo Fusconi
    Guido Benfari
    Giulio Pagliuca
    Gianna Pulice
    Andrea Gallo
    European Archives of Oto-Rhino-Laryngology, 2008, 265 : 943 - 945
  • [6] The use of forced ventilation during microlaryngoscopy with laser CO2
    de Vincentiis, Marco
    Fusconi, Massimo
    Benfari, Guido
    Pagliuca, Giulio
    Pulice, Gianna
    Gallo, Andrea
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2008, 265 (08) : 943 - 945
  • [7] TESTING OF 2 WAYS OF KEEPING UP A MINIMAL RATE OF VENTILATION IN A FATTENING HOUSE
    GRANIER, R
    DELAFARGE, B
    ANNALES DE ZOOTECHNIE, 1985, 34 (03): : 375 - 375
  • [8] USE OF CO2 CONCENTRATION DIFFERENCE OR CO2 BALANCE TO ASSESS VENTILATION RATE OF BROILER HOUSES
    Xin, H.
    Li, H.
    Burns, R. T.
    Gates, R. S.
    Overhults, D. G.
    Earnest, J. W.
    TRANSACTIONS OF THE ASABE, 2009, 52 (04) : 1353 - 1361
  • [9] Seasonal CO2 balances of a subarctic mire
    Aurela, M
    Laurila, T
    Tuovinen, JP
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2001, 106 (D2) : 1623 - 1637
  • [10] CO2 ROLE IN VENTILATION
    JANU, G
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1993, 35 (10): : 95 - 96