Cell-transistor hybrid systems and their potential applications

被引:78
作者
Offenhäusser, A [1 ]
Knoll, W [1 ]
机构
[1] Max Planck Inst Polymer Res, D-55128 Mainz, Germany
关键词
D O I
10.1016/S0167-7799(00)01544-4
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Electrogenic cells fire spontaneous or triggered action potentials (transient changes of their membrane potentials) and can be electronically coupled to external electrodes (arrays). Signals from rat heart-muscle cells were recorded by a field-effect transistor and the results described on the basis of an equivalent circuit. This technique has potential applications in drug screening. such as measuring the dose-response curve of isoproterenol, a beta -adrenergic agonist with a positive chronotropic effect.
引用
收藏
页码:62 / 66
页数:5
相关论文
共 19 条
[1]   EXTRACELLULAR POTENTIAL RECORDINGS BY MEANS OF A FIELD-EFFECT TRANSISTOR WITHOUT GATE METAL, CALLED OSFET [J].
BERGVELD, P ;
WIERSMA, J ;
MEERTENS, H .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1976, 23 (02) :136-144
[2]   STUDY OF INSULATOR MATERIALS USED IN ISFET GATES [J].
COHEN, RM ;
HUBER, RJ ;
JANATA, J ;
URE, RW ;
MOSS, SD .
THIN SOLID FILMS, 1978, 53 (02) :169-173
[3]  
Denyer MCT, 1999, IN VITRO CELL DEV-AN, V35, P352
[4]   A NEURON-SILICON JUNCTION - A RETZIUS CELL OF THE LEECH ON AN INSULATED-GATE FIELD-EFFECT TRANSISTOR [J].
FROMHERZ, P ;
OFFENHAUSSER, A ;
VETTER, T ;
WEIS, J .
SCIENCE, 1991, 252 (5010) :1290-1293
[5]   Extracellular recording with transistors and the distribution of ionic conductances in a cell membrane [J].
Fromherz, P .
EUROPEAN BIOPHYSICS JOURNAL WITH BIOPHYSICS LETTERS, 1999, 28 (03) :254-258
[6]  
GEDDES LA, 1992, ELECT MEASUREMENTS B
[7]   SIMULTANEOUS OPTICAL MEASUREMENTS OF ELECTRICAL-ACTIVITY FROM MULTIPLE SITES ON PROCESSES OF CULTURED NEURONS [J].
GRINVALD, A ;
ROSS, WN ;
FARBER, I .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA-BIOLOGICAL SCIENCES, 1981, 78 (05) :3245-3249
[8]   NEW FIXED-ARRAY MULTI-MICROELECTRODE SYSTEM DESIGNED FOR LONG-TERM MONITORING OF EXTRACELLULAR SINGLE UNIT NEURONAL-ACTIVITY INVITRO [J].
GROSS, GW ;
RIESKE, E ;
KREUTZBERG, GW ;
MEYER, A .
NEUROSCIENCE LETTERS, 1977, 6 (2-3) :101-105
[9]   ACTIVE MICROELECTRODE ARRAY TO RECORD FROM THE MAMMALIAN CENTRAL NERVOUS-SYSTEM INVITRO [J].
JOBLING, DT ;
SMITH, JG ;
WHEAL, HV .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1981, 19 (05) :553-560
[10]   Extended gate electrode arrays for extracellular signal recordings [J].
Krause, M ;
Ingebrandt, S ;
Richter, D ;
Denyer, M ;
Scholl, M ;
Sprössler, C ;
Offenhäusser, A .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 70 (1-3) :101-107