Radiation Dose and Image Quality of a High-Pitch Prospective Spiral First Approach in Coronary Computed Tomography Angiography (CCTA)

被引:5
|
作者
Finck, Tom [1 ]
Klambauer, Konstantin [1 ]
Hendrich, Eva [1 ]
Will, Albrecht [1 ]
Martinoff, Stefan [1 ]
Hadamitzky, Martin [1 ]
机构
[1] German Heart Ctr Munich, Inst Radiol & Nucl Med, Lazarettstr 36, D-80636 Munich, Germany
关键词
coronary computed tomography angiography; high-pitch-spiral scan; radiation exposure; coronary artery disease; DUAL-SOURCE CT; ACQUISITION; PROTECTION; ACCURACY;
D O I
10.3390/jcdd8100119
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To investigate a high-pitch spiral first (HPSF) approach for coronary computed tomography angiography (CCTA) in an unselected patient cohort and compare diagnostic yield and radiation exposure to CCTAs acquired via conventional, non-high-pitch spiral first (NHPSF) scan regimes. Materials and Methods: All consecutive patients from 1 January 2015 to 31 December 2017 were included. Two investigation protocols (HPSF/NHPSF) were used with the aim to achieve diagnostic image quality of all coronary segments. Low-pitch secondary scans followed the initial examination if image quality was unsatisfactory. Dosage and image quality were compared between both regimes. Results: 1410 patients were subject to a HPSF and 236 patients to a NHPSF approach. While the HPSF approach led to a higher fraction of re-scans (35% vs. 11%, p < 0.001), the fraction of aggregate scans that remained non-diagnostic after considering the initial and secondary scan was comparably low for the HPSF and NHPSF approach (0.78 vs. 0%, p = 0.18). Aggregate radiation exposure in the HPSF protocol was significantly lower (1.12 mSv (IQR: 0.73, 2.10) vs. 3.96 mSv (IQR: 2.23, 8.33) p < 0.001). Conclusions: In spite of a higher number of re-scans, a HPSF approach leads to a reduction in overall radiation exposure with diagnostic yields similar to a NHPSF approach.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Computed tomography coronary angiography with a consistent dose below 2 mSv using double prospectively ECG-triggered high-pitch spiral acquisition in patients with atrial fibrillation: initial experience
    Wang, Qi
    Qin, Jing
    He, Bai
    Zhou, Yin
    Yang, Jun-jie
    Hou, Xiao-ling
    Yang, Xiao-bo
    Chen, Jiu-hong
    Chen, Yun-dai
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (06) : 1341 - 1349
  • [32] Image Quality of ECG-Triggered High-Pitch, Dual-Source Computed Tomography Angiography for Cardiovascular Assessment in Children
    Barrera, Christian A.
    Otero, Hansel J.
    White, Ammie M.
    Saul, David
    Biko, David M.
    CURRENT PROBLEMS IN DIAGNOSTIC RADIOLOGY, 2020, 49 (01) : 23 - 28
  • [33] Computed tomography coronary angiography with a consistent dose below 2 mSv using double prospectively ECG-triggered high-pitch spiral acquisition in patients with atrial fibrillation: initial experience
    Qi Wang
    Jing Qin
    Bai He
    Yin Zhou
    Jun-jie Yang
    Xiao-ling Hou
    Xiao-bo Yang
    Jiu-hong Chen
    Yun-dai Chen
    The International Journal of Cardiovascular Imaging, 2013, 29 : 1341 - 1349
  • [34] Image quality, radiation dose, and diagnostic accuracy of prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp in a clinical setting: comparison with invasive coronary angiography
    Zhang, Long Jiang
    Wang, Yining
    Schoepf, U. Joseph
    Meinel, Felix G.
    Bayer, Richard R., II
    Qi, Li
    Cao, Jian
    Zhou, Chang Sheng
    Zhao, Yan E.
    Li, Xie
    Bin Gong, Jian
    Jin, Zhengyu
    Lu, Guang Ming
    EUROPEAN RADIOLOGY, 2016, 26 (03) : 797 - 806
  • [35] High-Pitch Photon-Counting Detector Computed Tomography Angiography of the Aorta Intraindividual Comparison to Energy-Integrating Detector Computed Tomography at Equal Radiation Dose
    Euler, Andre
    Higashigaito, Kai
    Mergen, Victor
    Sartoretti, Thomas
    Zanini, Bettina
    Schmidt, Bernhard
    Flohr, Thomas G.
    Ulzheimer, Stefan
    Eberhard, Matthias
    Alkadhi, Hatem
    INVESTIGATIVE RADIOLOGY, 2022, 57 (02) : 115 - 121
  • [36] Radiation dose reduction in paediatric coronary computed tomography: assessment of effective dose and image quality
    Geryes, Bouchra Habib
    Calmon, Raphael
    Khraiche, Diala
    Boddaert, Nathalie
    Bonnet, Damien
    Raimondi, Francesca
    EUROPEAN RADIOLOGY, 2016, 26 (07) : 2030 - 2038
  • [37] Comparison of sequential and high-pitch-spiral coronary CT-angiography: image quality and radiation exposure
    Seppelt, D.
    Kolb, C.
    Kuehn, J. P.
    Speiser, U.
    Radosa, C. G.
    Hoberueck, S.
    Hoffmann, R. T.
    Platzek, I.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (07) : 1379 - 1386
  • [38] Comparison of sequential and high-pitch-spiral coronary CT-angiography: image quality and radiation exposure
    D. Seppelt
    C. Kolb
    J. P. Kühn
    U. Speiser
    C. G. Radosa
    S. Hoberück
    R. T. Hoffmann
    I. Platzek
    The International Journal of Cardiovascular Imaging, 2019, 35 : 1379 - 1386
  • [39] Detection of coronary artery stenosis with sub-milliSievert radiation dose by prospectively ECG-triggered high-pitch spiral CT angiography and iterative reconstruction
    Wei-Hua Yin
    Bin Lu
    Zhi-Hui Hou
    Nan Li
    Lei Han
    Yong-Jian Wu
    Hong-Xia Niu
    Justin R. Silverman
    Carlo Nicola De Cecco
    U. Joseph Schoepf
    European Radiology, 2013, 23 : 2927 - 2933
  • [40] Accuracy, image quality and radiation dose comparison of high-pitch spiral and sequential acquisition on 128-slice dual-source CT angiography in children with congenital heart disease
    Pei Nie
    Ximing Wang
    Zhaoping Cheng
    Xiaopeng Ji
    Yanhua Duan
    Jiuhong Chen
    European Radiology, 2012, 22 : 2057 - 2066