It is STILL necessary to validate each individual IMRT treatment plan with dosimetric measurements before delivery

被引:28
作者
Smith, J. Charles [1 ]
Dieterich, Sonja [2 ]
Orton, Colin G.
机构
[1] St Joseph Mercy, Port Huron, MI 48060 USA
[2] Stanford Univ Hosp, Dept Radiat Oncol, Stanford, CA 94305 USA
关键词
ERRORS;
D O I
10.1118/1.3512801
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:553 / 555
页数:3
相关论文
共 9 条
[1]   EVALUATION OF SAFETY IN A RADIATION ONCOLOGY SETTING USING FAILURE MODE AND EFFECTS ANALYSIS [J].
Ford, Eric C. ;
Gaudette, Ray ;
Myers, Lee ;
Vanderver, Bruce ;
Engineer, Lilly ;
Zellars, Richard ;
Song, Danny Y. ;
Wong, John ;
DeWeese, Theodore L. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (03) :852-858
[2]   Challenges in Credentialing Institutions and Participants in Advanced Technology Multi-institutional Clinical Trials [J].
Radiological Physics Center, The University of Texas M. D. Anderson Cancer Center, Houston, TX, United States .
Int. J. Radiat. Oncol. Biol. Phys., 2008, 1 SUPPL. (S71-S75) :S71-S75
[3]   The management of respiratory motion in radiation oncology report of AAPM Task Group 76 [J].
Keall, Paul J. ;
Mageras, Gig S. ;
Balter, James M. ;
Emery, Richard S. ;
Forster, Kenneth M. ;
Jiang, Steve B. ;
Kapatoes, Jeffrey M. ;
Low, Daniel A. ;
Murphy, Martin J. ;
Murray, Brad R. ;
Ramsey, Chester R. ;
Van Herk, Marcel B. ;
Vedam, S. Sastry ;
Wong, John W. ;
Yorke, Ellen .
MEDICAL PHYSICS, 2006, 33 (10) :3874-3900
[4]   Task Group 142 report: Quality assurance of medical accelerators [J].
Klein, Eric E. ;
Hanley, Joseph ;
Bayouth, John ;
Yin, Fang-Fang ;
Simon, William ;
Dresser, Sean ;
Serago, Christopher ;
Aguirre, Francisco ;
Ma, Lijun ;
Arjomandy, Bijan ;
Liu, Chihray ;
Sandin, Carlos ;
Holmes, Todd .
MEDICAL PHYSICS, 2009, 36 (09) :4197-4212
[5]   On the insensitivity of single field planar dosimetry to IMRT inaccuracies [J].
Kruse, Jon J. .
MEDICAL PHYSICS, 2010, 37 (06) :2516-2524
[6]   Catching errors with in vivo EPID dosimetry [J].
Mans, A. ;
Wendling, M. ;
McDermott, L. N. ;
Sonke, J. -J. ;
Tielenburg, R. ;
Vijlbrief, R. ;
Mijnheer, B. ;
van Herk, M. ;
Stroom, J. C. .
MEDICAL PHYSICS, 2010, 37 (06) :2638-2644
[7]  
Papanikolaou N., 2004, 85 AAPM, DOI 10.37206/86
[8]   The sensitivity of patient specific IMRT QC to systematic MLC leaf bank offset errors [J].
Rangel, Alejandra ;
Palte, Gesa ;
Dunscombe, Peter .
MEDICAL PHYSICS, 2010, 37 (07) :3862-3867
[9]  
[No title captured]