Design and performance of the readout electronics for the CsI(Tl) detector

被引:8
作者
Kudenko, YG
Mineev, OV
Imazato, J
机构
[1] Russian Acad Sci, Inst Nucl Res, Moscow 117312, Russia
[2] KEK, High Energy Accelerator Res Org, Inst Particle & Nucl Studies, Tsukuba, Ibaraki 305, Japan
关键词
photodiodes; constant-fraction discriminator; baseline restorer;
D O I
10.1016/S0168-9002(98)00273-3
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper describes a readout electronics system constructed for the CsI(Tl) calorimetry of neutral pions in experiment E246 at KEK. The instrumentation was designed to cover a wide range of energies (from 300 keV to 300 MeV) with high measurement accuracy under a counting rate of a few ten kHz per channel. The readout is provided by one 18 x 18 mm(2) (or 28 x 28 mm(2)) Hamamatsu PIN-photodiode coupled directly to the rear end of each CsI(TI) crystal. A charge-sensitive preamplifier was developed specifically to have low noise for a high photodiode capacitance, The equivalent noise charge of the photodiode-preamplifier system at a 2 mu s shaping time was found to be 640 and 840 electrons for 18 x 18 and 28 x 28 mm(2) photodiodes, respectively. A pulse processor consists of a shaping amplifier with two outputs to cover the large dynamic range and a timing filter amplifier, A baseline restorer incorporated into the shaping amplifier retains good energy resolution under rates up to 50 kHz. A multichannel constant-fraction discriminator was designed to accept long risetime signals. A time resolution of 11.4 ns (fwhm) has been achieved in beam runs for the photon energy range from 10 to 200 MeV. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:437 / 448
页数:12
相关论文
共 12 条
[1]  
*CLEAR PULS CO, TECHN MAN 4040 FILT
[2]   CsI(Tl) calorimeter with photodiode readout to search for T-violation in K-mu 3 decay [J].
Dementyev, DV ;
Grigorjev, MP ;
Igarashi, Y ;
Ikeda, T ;
Imazato, J ;
Ivashkin, AP ;
Khabibullin, MM ;
Kudenko, YG ;
Kuno, Y ;
Mineev, OV ;
Shimizu, S ;
Watanabe, A ;
Yokoi, T .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 379 (03) :499-501
[3]   TIMING DISCRIMINATOR USING LEADING-EDGE EXTRAPOLATION [J].
GOTTSCHALK, B .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1981, 190 (01) :67-70
[4]   SILICON PIN PHOTODETECTORS IN HIGH-RESOLUTION NUCLEAR SPECTROSCOPY [J].
GRAMSCH, E ;
LYNN, KG ;
WEBER, M ;
DECHILLO, B ;
MCWILLIAMS, JR .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 311 (03) :529-538
[5]  
Grigorev MF, 1996, INSTRUM EXP TECH+, V39, P164
[6]  
IMAZATO J, 1991, 918 KEK
[7]  
KUDENKO YG, 1992, 9215 KEK
[8]   ELIMINATION OF A LOW-FREQUENCY LARGE-AMPLITUDE NOISE USING THE IMPROVED BASE-LINE RESTORER EMPLOYING GAIN SWITCHING [J].
OHKAWA, S ;
HUSIMI, K .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) :415-418
[9]   NEW ELECTRONICS SYSTEM FOR SILICON STRIP READOUT FOR 18KEV ELECTRONS [J].
TANIGUCHI, T ;
FUKUSHIMA, Y ;
YORIBAYASHI, Y .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :657-661
[10]  
*TKO, 1985, 8510 KEK