共 43 条
Mirror-enhanced super-resolution microscopy
被引:77
作者:
Yang, Xusan
[1
]
Xie, Hao
[1
,2
,3
]
Alonas, Eric
[2
,3
]
Liu, Yujia
[1
,4
]
Chen, Xuanze
[1
]
Santangelo, Philip J.
[2
,3
]
Ren, Qiushi
[1
]
Xi, Peng
[1
,2
,3
,4
,5
]
Jin, Dayong
[4
,5
]
机构:
[1] Peking Univ, Dept Biomed Engn, Coll Engn, 5 Yiheyuan Rd, Beijing 100871, Peoples R China
[2] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, Atlanta, GA 30332 USA
[3] Emory Univ, Atlanta, GA 30332 USA
[4] Macquarie Univ, ARC Ctr Excellence Nanoscale BioPhoton CNBP, Adv Cytometry Labs, Sydney, NSW 2109, Australia
[5] Univ Technol Sydney, IBMD, Fac Sci, Sydney, NSW 2007, Australia
基金:
澳大利亚研究理事会;
关键词:
confocal;
interference;
point spread function;
super-resolution;
NUCLEAR-PORE COMPLEX;
NM AXIAL RESOLUTION;
FLUORESCENCE MICROSCOPY;
STED NANOSCOPY;
OPTICAL NANOSCOPY;
SCALE RESOLUTION;
LIGHT;
CELLS;
ARCHITECTURE;
(IM)-M-5;
D O I:
10.1038/lsa.2016.134
中图分类号:
O43 [光学];
学科分类号:
070207 ;
0803 ;
摘要:
Axial excitation confinement beyond the diffraction limit is crucial to the development of next-generation, super-resolution microscopy. STimulated Emission Depletion (STED) nanoscopy offers lateral super-resolution using a donut-beam depletion, but its axial resolution is still over 500 nm. Total internal reflection fluorescence microscopy is widely used for single-molecule localization, but its ability to detect molecules is limited to within the evanescent field of similar to 100 nm from the cell attachment surface. We find here that the axial thickness of the point spread function (PSF) during confocal excitation can be easily improved to 110 nm by replacing the microscopy slide with a mirror. The interference of the local electromagnetic field confined the confocal PSF to a 110-nm spot axially, which enables axial super-resolution with all laser-scanning microscopes. Axial sectioning can be obtained with wavelength modulation or by controlling the spacer between the mirror and the specimen. With no additional complexity, the mirror-assisted excitation confinement enhanced the axial resolution six-fold and the lateral resolution two-fold for STED, which together achieved 19-nm resolution to resolve the inner rim of a nuclear pore complex and to discriminate the contents of 120 nm viral filaments. The ability to increase the lateral resolution and decrease the thickness of an axial section using mirror-enhanced STED without increasing the laser power is of great importance for imaging biological specimens, which cannot tolerate high laser power.
引用
收藏
页码:e16134 / e16134
页数:8
相关论文